Pulse-to-pulse coherent Doppler measurements of waves and turbulence

被引:0
作者
Veron, F [1 ]
Melville, WK [1 ]
机构
[1] Univ Calif San Diego, Scripps Inst Oceanog, La Jolla, CA 92093 USA
关键词
D O I
10.1175/1520-0426(1999)016<1580:PTPCDM>2.0.CO;2
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
This paper presents laboratory and field testing of a pulse-to-purse coherent acoustic Doppler profiler for the measurement of turbulence in the ocean. In the laboratory, velocities and wavenumber spectra collected From Doppler and digital particle image velocimeter measurements compare very well. Turbulent velocities are obtained by identifying and filtering out deep water gravity waves in Fourier space and inverting the result. Spectra of the velocity profiles then reveal the presence of an inertial subrange in the turbulence generated by unsteady breaking waves. In the field, comparison of the profiler velocity records with a single-point current measurement is satisfactory. Again wavenumber spectra are directly measured and exhibit an approximate -5/3 slope. It is concluded that the instrument is capable of directly resolving the wavenumber spectral levels in the inertial subrange under breaking waves, and therefore is capable of measuring dissipation and other turbulence parameters in the upper mixed layer or surface-wave zone.
引用
收藏
页码:1580 / 1597
页数:18
相关论文
共 50 条
[21]   Pulse-to-pulse coupling in cylindrical discharges [J].
Hazenberg, T. ;
van Dijk, J. ;
van Oijen, J. A. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2024, 57 (35)
[22]   A search for pulse-to-pulse variability of the Crab pulsar [J].
Patt, BL ;
Ulmer, MP ;
Zhang, W ;
Cordes, JM ;
Arzoumanian, Z .
ASTROPHYSICAL JOURNAL, 1999, 522 (01) :440-443
[23]   Control of pulse-to-pulse fluctuations in visible supercontinuum [J].
Kudlinski, A. ;
Barviau, B. ;
Leray, A. ;
Spriet, C. ;
Heliot, L. ;
Mussot, A. .
OPTICS EXPRESS, 2010, 18 (26) :27445-27454
[24]   SIMPLE LINEAR PULSE-TO-PULSE CARDIAC TACHOMETER [J].
ROY, OZ ;
WEHNERT, RW .
MEDICAL & BIOLOGICAL ENGINEERING, 1974, 12 (03) :370-373
[25]   PULSE-TO-PULSE CORRELATION IN SATELLITE RADAR ALTIMETERS [J].
WALSH, EJ .
RADIO SCIENCE, 1982, 17 (04) :786-800
[26]   Time-Domain Envelope Measurements and Simulations of Pulse-to-Pulse Stability in Microwave Power Amplifiers [J].
Delprato, Julien ;
Barataud, Denis ;
Campovecchio, Michel ;
Neveux, Guillaume ;
Tolant, Clement ;
Eudeline, Philippe .
2014 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2014,
[27]   A high resolution constant beam width pulse-to-pulse coherent 3-D acoustic Doppler profiling current meter for use in laboratory and environmental studies [J].
Lemmin, U ;
Hurther, D ;
Shen, C .
PROCEEDINGS OF THE IEEE SIXTH WORKING CONFERENCE ON CURRENT MEASUREMENT, 1999, :216-220
[28]   COMPENSATING PULSE-TO-PULSE FLUCTUATIONS AND INCREASING SPECTRAL REPRODUCIBILITY OF PHASE-MATCHED CARS MEASUREMENTS [J].
SCHOLTEN, TAHM ;
LUCASSEN, GW ;
DEMUL, FFM ;
GREVE, J .
APPLIED OPTICS, 1988, 27 (15) :3225-3332
[29]   Pulse-to-Pulse Circuit Reconfiguration in Spectrum Sensing Radar [J].
Van Hoosier, Trevor ;
Alexander, Jordan ;
Egbert, Austin ;
Roessler, Justin ;
Baylis, Charles ;
Marks, Robert J. .
2023 IEEE RADAR CONFERENCE, RADARCONF23, 2023,
[30]   PULSE-TO-PULSE MODULATION OF CERN-PS COMPLEX [J].
POTIER, JP .
BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (02) :156-156