Pulse-to-pulse coherent Doppler measurements of waves and turbulence

被引:0
作者
Veron, F [1 ]
Melville, WK [1 ]
机构
[1] Univ Calif San Diego, Scripps Inst Oceanog, La Jolla, CA 92093 USA
关键词
D O I
10.1175/1520-0426(1999)016<1580:PTPCDM>2.0.CO;2
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
This paper presents laboratory and field testing of a pulse-to-purse coherent acoustic Doppler profiler for the measurement of turbulence in the ocean. In the laboratory, velocities and wavenumber spectra collected From Doppler and digital particle image velocimeter measurements compare very well. Turbulent velocities are obtained by identifying and filtering out deep water gravity waves in Fourier space and inverting the result. Spectra of the velocity profiles then reveal the presence of an inertial subrange in the turbulence generated by unsteady breaking waves. In the field, comparison of the profiler velocity records with a single-point current measurement is satisfactory. Again wavenumber spectra are directly measured and exhibit an approximate -5/3 slope. It is concluded that the instrument is capable of directly resolving the wavenumber spectral levels in the inertial subrange under breaking waves, and therefore is capable of measuring dissipation and other turbulence parameters in the upper mixed layer or surface-wave zone.
引用
收藏
页码:1580 / 1597
页数:18
相关论文
共 50 条
  • [21] Control of pulse-to-pulse fluctuations in visible supercontinuum
    Kudlinski, A.
    Barviau, B.
    Leray, A.
    Spriet, C.
    Heliot, L.
    Mussot, A.
    OPTICS EXPRESS, 2010, 18 (26): : 27445 - 27454
  • [22] A search for pulse-to-pulse variability of the Crab pulsar
    Patt, BL
    Ulmer, MP
    Zhang, W
    Cordes, JM
    Arzoumanian, Z
    ASTROPHYSICAL JOURNAL, 1999, 522 (01) : 440 - 443
  • [23] SIMPLE LINEAR PULSE-TO-PULSE CARDIAC TACHOMETER
    ROY, OZ
    WEHNERT, RW
    MEDICAL & BIOLOGICAL ENGINEERING, 1974, 12 (03): : 370 - 373
  • [24] PULSE-TO-PULSE CORRELATION IN SATELLITE RADAR ALTIMETERS
    WALSH, EJ
    RADIO SCIENCE, 1982, 17 (04) : 786 - 800
  • [25] Time-Domain Envelope Measurements and Simulations of Pulse-to-Pulse Stability in Microwave Power Amplifiers
    Delprato, Julien
    Barataud, Denis
    Campovecchio, Michel
    Neveux, Guillaume
    Tolant, Clement
    Eudeline, Philippe
    2014 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2014,
  • [26] A high resolution constant beam width pulse-to-pulse coherent 3-D acoustic Doppler profiling current meter for use in laboratory and environmental studies
    Lemmin, U
    Hurther, D
    Shen, C
    PROCEEDINGS OF THE IEEE SIXTH WORKING CONFERENCE ON CURRENT MEASUREMENT, 1999, : 216 - 220
  • [27] COMPENSATING PULSE-TO-PULSE FLUCTUATIONS AND INCREASING SPECTRAL REPRODUCIBILITY OF PHASE-MATCHED CARS MEASUREMENTS
    SCHOLTEN, TAHM
    LUCASSEN, GW
    DEMUL, FFM
    GREVE, J
    APPLIED OPTICS, 1988, 27 (15): : 3225 - 3332
  • [28] Pulse-to-Pulse Circuit Reconfiguration in Spectrum Sensing Radar
    Van Hoosier, Trevor
    Alexander, Jordan
    Egbert, Austin
    Roessler, Justin
    Baylis, Charles
    Marks, Robert J.
    2023 IEEE RADAR CONFERENCE, RADARCONF23, 2023,
  • [29] PULSE-TO-PULSE MODULATION OF CERN-PS COMPLEX
    POTIER, JP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (02): : 156 - 156
  • [30] Pulse-coherent acoustic Doppler profiler
    Polonichko, V
    Mullison, J
    Cabrera, R
    SEA TECHNOLOGY, 2000, 41 (02) : 76 - 78