Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing

被引:22
作者
Consolo, Ugo [1 ]
Travaglini, Domenico
Todisco, Marzio
Trisi, Paolo
Galli, Silvia
机构
[1] Univ Modena & Reggio Emilia, Fac Odontoiatria & Protesi Dent, I-41100 Modena, Italy
关键词
Dental implant; insertion torque; peri-implant bone; DENTAL IMPLANTS; DENSITY; MICROMOTION; INTERFACE; STABILITY;
D O I
10.1097/SCS.0b013e31827ca3cf
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this study was to evaluate histologically and biomechanically the peri-implant bone healing around implants placed with high torque after a follow-up of 8 and 12 weeks. A total of 12 implants were placed in the lower edge of the mandible of 2 sheep. In each sheep, 3 implants were placed with a low torque (<25 N center dot cm, LT group) as a control, and 3 implants were placed with a high insertion torque (maximum torque, HT group). The sheep were killed after 8 and 12 weeks of healing, and the implants were examined for removal torque, resonance frequency analysis, and histologic analysis. The mean insertion torque in the LT group was 24 N center dot cm, whereas it was 105.6 N center dot cm in HT. All the implants osseointegrated and histologic analysis showed similar aspects of the peri-implant bone tissue for both groups and both healing times. Mean removal torque values for LT implants were 159.5 and 131.5 N center dot cm after 8 and 12 weeks, respectively, whereas those for the HT were 140 and 120 N center dot cm at 8 and 12 weeks, respectively. Implant stability quotient values were 26.6 and 76 for the LT group and 74 and 76 for the HT group at 8 and 12 weeks, respectively. It could be concluded that high implant insertion torque does not induce adverse reaction in cortical bone and does not lead to implant failure.
引用
收藏
页码:860 / 865
页数:6
相关论文
共 24 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]   State of the art of oral implants [J].
Albrektsson, Tomas ;
sennerby, Lars ;
Wennerberg, Ann .
PERIODONTOLOGY 2000, 2008, 47 :15-26
[3]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[4]  
Cannizzaro G, 2003, INT J ORAL MAX IMPL, V18, P512
[5]  
Davies John E, 2003, J Dent Educ, V67, P932
[6]  
Johansson C, 1987, Int J Oral Maxillofac Implants, V2, P69
[7]   The biology of fracture healing [J].
Marsell, Richard ;
Einhorn, Thomas A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (06) :551-555
[8]   Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants [J].
Meyer, U ;
Joos, U ;
Mythili, J ;
Stamm, T ;
Hohoff, A ;
Fillies, T ;
Stratmann, U ;
Wiesmann, HP .
BIOMATERIALS, 2004, 25 (10) :1959-1967
[9]  
Misch Carl E, 2004, Implant Dent, V13, P310
[10]  
O'Sullivan D, 2000, Clin Implant Dent Relat Res, V2, P85, DOI 10.1111/j.1708-8208.2000.tb00110.x