Condition-based maintenance (also called predictive maintenance) requires diagnostic tools to determine when significant insulation aging has occurred, and thus when maintenance is necessary to avoid an in-service failure. Over the years many off-line diagnostic tests and on-line monitoring systems have been proposed and implemented, especially on critical motors and generators. In the past decade, most of the research has concentrated on improving existing off-line diagnostic tests and on-line monitoring such as magnetic flux, partial discharge, temperature, endwinding vibration, etc. However, some newer tests such as polarization/depolarization current, dielectric spectroscopy and on-line leakage current monitoring have been introduced. These tests and monitoring systems are reviewed. Tests and monitoring systems for rotor winding insulation and stator winding insulation are addressed separately.
引用
收藏
页码:2073 / 2080
页数:8
相关论文
共 36 条
[1]   INTERTURN SHORT-CIRCUIT DETECTOR FOR TURBINE-GENERATOR ROTOR WINDINGS [J].
ALBRIGHT, DR .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (02) :478-&
[2]  
Albright DR, 1999, POWER ENG, V103, P28
[3]   Investigation and diagnosis of a 184-MVA air-cooled generator heavily affected by slot partial discharge activity [J].
Belec, M. ;
Li, S. ;
Nguyen, D. N. ;
Lepine, L. ;
Guddemi, C. ;
Lessard-Deziel, D. ;
Schwartz, T. ;
Lamarre, L. ;
Belec, Mario .
2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, :85-90
[4]   On-site Non-destructive Dielectric Response Diagnosis of Rotating Machines [J].
Bhumiwat, Supatra A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) :1453-1460
[5]   FUNDAMENTAL LIMITATIONS IN THE MEASUREMENT OF CORONA AND PARTIAL DISCHARGE [J].
BOGGS, SA ;
STONE, GC .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (02) :143-150
[6]   OPERATIONAL PERFORMANCE OF GENERATOR CONDITION MONITORS - COMPARISON OF HEATED AND UNHEATED ION CHAMBERS [J].
BRAUN, JM ;
BROWN, G .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (02) :344-349
[7]   USE OF A MIXED-WEIBULL DISTRIBUTION FOR THE IDENTIFICATION OF PD PHENOMENA [J].
CACCIARI, M ;
CONTIN, A ;
MONTANARI, GC .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (04) :614-627
[8]   PRACTICAL ONLINE PARTIAL DISCHARGE TESTS FOR TURBINE GENERATORS AND MOTORS [J].
CAMPBELL, SR ;
STONE, GC ;
SEDDING, HG ;
KLEMPNER, GS ;
MCDERMID, W ;
BUSSEY, RG .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (02) :281-287
[9]   Characterization of patch antennae for PD detection in power cables [J].
Cavallini, A. ;
Montanari, G. C. ;
Salsi, A. .
2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, :179-+
[10]   A new algorithm for the identification of defects generating partial discharges in rotating machines [J].
Cavallini, A ;
Conti, M ;
Contin, A ;
Montanari, GC ;
Puletti, F .
CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, :204-207