Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD

被引:23
|
作者
Gao, Jie [1 ]
Zhang, Min [2 ]
Zhou, Liqin [1 ]
Yang, Xing [1 ]
Wu, Haigui [1 ]
Zhang, Jianfang [1 ]
Wu, Feng [1 ]
机构
[1] Guangzhou Med Univ, Dept Resp Med, Peoples Hosp 3, 1 Xuebei Ave, Huizhou 516002, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Internal Med Cardiovasc Dept, Peoples Hosp 3, Huizhou, Peoples R China
来源
INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE | 2017年 / 12卷
关键词
fractional exhaled nitric oxide; eosinophils in induced sputum; blood eosinophil percentage; chronic obstructive pulmonary disease; AIRWAY EOSINOPHILIA; ASTHMA;
D O I
10.2147/COPD.S134998
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. Methods: A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (>= 2.5%)/FeNO levels (>= 32 parts per billion [ppb]). Results: FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (rho=0.221, P=0.005) and blood eosinophilic percentage (rho=0.399, P < 0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65-0.81, P. 0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity = 61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53-3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). Conclusion: The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [1] Predicting Sputum Eosinophilia in Exacerbations of COPD Using Exhaled Nitric Oxide
    Soter, Szabolcs
    Barta, Imre
    Antus, Balazs
    INFLAMMATION, 2013, 36 (05) : 1178 - 1185
  • [2] Predicting Sputum Eosinophilia in Exacerbations of COPD Using Exhaled Nitric Oxide
    Szabolcs Soter
    Imre Barta
    Balazs Antus
    Inflammation, 2013, 36 : 1178 - 1185
  • [3] Variability of fractional exhaled nitric oxide is associated with the risk and aetiology of COPD exacerbations
    Schumann, Desiree M. M.
    Papakonstantinou, Eleni
    Kostikas, Konstantinos
    Grize, Leticia
    Tamm, Michael
    Stolz, Daiana
    RESPIROLOGY, 2023, 28 (05) : 445 - 454
  • [4] Fractional exhaled nitric oxide and induced sputum
    Zacharasiewicz, Angela
    PAEDIATRIC RESPIRATORY REVIEWS, 2007, 8 (01) : 94 - 96
  • [5] Fractional Exhaled Nitric Oxide: Comparison Between Portable Devices and Correlation With Sputum Eosinophils
    Yune, Sehyo
    Lee, Jin-Young
    Choi, Dong-Chull
    Lee, Byung-Jae
    ALLERGY ASTHMA & IMMUNOLOGY RESEARCH, 2015, 7 (04) : 404 - 408
  • [6] Relationship between exhaled nitric oxide and treatment response in COPD patients with exacerbations
    Antus, Balazs
    Barta, Imre
    Horvath, Ildiko
    Csiszer, Eszter
    RESPIROLOGY, 2010, 15 (03) : 472 - 477
  • [7] Correlation between Blood Eosinophilia and Fractional Exhaled Nitric Oxide in the diagnosis of Asthma within Primary Care
    Ghosh, Sudip
    Farrell, Lesley
    Panray, Gailash
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [8] Annual Fractional Exhaled Nitric Oxide Measurements and Exacerbations in Severe Asthma
    Abe, Yuki
    Suzuki, Masaru
    Kimura, Hirokazu
    Shimizu, Kaoruko
    Makita, Hironi
    Nishimura, Masaharu
    Konno, Satoshi
    JOURNAL OF ASTHMA AND ALLERGY, 2020, 13 : 731 - 741
  • [9] Importance of fractional exhaled nitric oxide in the differentiation of asthma-COPD overlap syndrome, asthma, and COPD
    Chen, Feng-jia
    Huang, Xin-yan
    Liu, Yang-li
    Lin, Geng-peng
    Xie, Can-mao
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 2385 - 2390
  • [10] Association between fractional exhaled nitric oxide, sputum induction and peripheral blood eosinophil in uncontrolled asthma
    Gao, Jie
    Wu, Feng
    ALLERGY ASTHMA AND CLINICAL IMMUNOLOGY, 2018, 14