Realization of relative responsivity scale with the electrically calibrated pyroelectric radiometer

被引:3
作者
Bazkir, Ozcan [1 ]
Celikel, Oguz [1 ]
Samedov, Farhad [1 ]
机构
[1] TUBITAK UME, TR-41470 Kocaeli, Turkey
关键词
pyroelectric radiometer; cryogenic radiometer; optical power; responsivity;
D O I
10.1016/j.optlastec.2005.03.004
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In UME, the relative spectral responsivity scale extending from 250 to 2500nm was realized using electrically calibrated pyroelectric radiometer (ECPR). Its absolute spectral responsivity was determined against the electrical substitution cryogenic radiometer (ESCR) facility at 488.1, 514.6, 532.0, and 632.8 nm with an uncertainty of 1 part in 10(4) (k = 2). The relative spectral responsivity scale of ECPR was derived from the surface reflectance data and absolute spectral responsivity data for the mentioned spectral range. Optical characterization of its spatial non-uniformity (at 632.8 nm) and surface reflectance (over 250-2500 nm wavelength region) indicated that the gold-black absorber is spectrally flat within 0.1%. The total expanded uncertainty in the realization of the mentioned radiometric scale along with ECPR was estimated as 1.74%. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 11 条
[1]   High-accuracy optical power measurements by using electrical-substitution cryogenic radiometer -: art. no. 016401 [J].
Bazkir, Ö ;
Ugur, S ;
Samedov, F ;
Esendemir, A .
OPTICAL ENGINEERING, 2005, 44 (01) :1-6
[2]   Characterization of silicon photodiode-based trap detectors and establishment of spectral responsivity scale [J].
Bazkir, Ö ;
Samadov, F .
OPTICS AND LASERS IN ENGINEERING, 2005, 43 (02) :131-141
[3]   ELECTRICALLY CALIBRATED ABSOLUTE RADIOMETER SUITABLE FOR MEASUREMENT AUTOMATION [J].
BOIVIN, LP ;
MCNEELY, FT .
APPLIED OPTICS, 1986, 25 (04) :554-561
[4]   IMPLEMENTATION OF A SYSTEM OF OPTICAL CALIBRATION BASED ON PYROELECTRIC RADIOMETRY [J].
DOYLE, WM ;
MCINTOSH, BC ;
GEIST, J .
OPTICAL ENGINEERING, 1976, 15 (06) :541-548
[5]   A PHYSICAL BASIS FOR THE EXTRAPOLATION OF SILICON PHOTODIODE QUANTUM EFFICIENCY INTO THE ULTRAVIOLET [J].
DURANT, NM ;
FOX, NP .
METROLOGIA, 1993, 30 (04) :345-350
[6]   NUMERICAL MODELING OF SHORT-WAVELENGTH INTERNAL QUANTUM EFFICIENCY [J].
GEIST, J ;
CHANDLERHOROWITZ, D ;
KOHLER, R ;
ROBINSON, AM ;
JAMES, CR .
METROLOGIA, 1991, 28 (03) :193-196
[7]   Calibration of a pyroelectric detector at 10.6 mu m with the National Institute of Standards and Technology high-accuracy cryogenic radiometer [J].
Gentile, TR ;
Houston, JM ;
Eppeldauer, G ;
Migdall, AL ;
Cromer, CL .
APPLIED OPTICS, 1997, 36 (16) :3614-3621
[8]   Present status of radiometric quality silicon photodiodes [J].
Korde, R ;
Prince, C ;
Cunningham, D ;
Vest, RE ;
Gullikson, E .
METROLOGIA, 2003, 40 (01) :S145-S149
[9]  
LARASON TC, 1998, NIST SPECIAL PUBLICA, V250
[10]   Domain-engineered pyroelectric radiometer [J].
Lehman, J ;
Eppeldauer, G ;
Aust, JA ;
Racz, M .
APPLIED OPTICS, 1999, 38 (34) :7047-7055