Quantifying resolution limiting factors in subtomogram averaged cryo-electron tomography using simulations

被引:13
作者
Voortman, Lenard M. [1 ]
Vulovic, Milos [1 ,2 ]
Maletta, Massimiliano [3 ]
Voigt, Andreas [4 ]
Franken, Erik M. [4 ]
Simonetti, Angelita [5 ]
Peters, Peter J. [2 ,3 ]
van Vliet, Lucas J. [1 ]
Rieger, Bernd [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Quantitat Imaging Grp, NL-2628 CJ Delft, Netherlands
[2] Maastricht Univ, Fac Hlth Med & Life Sci, Inst Nanoscopy, NL-6200 MD Maastricht, Netherlands
[3] Antoni van Leeuwenhoek Hosp, NKI Netherlands Canc Inst, NL-1066 CX Amsterdam, Netherlands
[4] FEI Co, NL-5651 GG Eindhoven, Netherlands
[5] Univ Strasbourg, CNRS, IBMC, Architecture & Reactivite ARN, F-67084 Strasbourg, France
关键词
Cryo-EM; Tomography; Subtomogram averaging; TEM image simulation; Tilted CTF correction; Acquisition protocol; Ribosome; TRANSMISSION ELECTRON-MICROSCOPY; BEAM-INDUCED MOTION; CRYO-EM; CRYOMICROSCOPY; VISUALIZATION; PROJECTION; ALIGNMENT; DEFOCUS;
D O I
10.1016/j.jsb.2014.06.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-electron tomography (CET) is the only available technique capable of characterizing the structure of biological macromolecules in conditions close to the native state. With the advent of subtomogram averaging, as a post-processing step to CET, resolutions in the (sub-) nanometer range have become within reach. In addition to advances in instrumentation and experiments, the reconstruction scheme has improved by inclusion of more accurate contrast transfer function (CTF) correction methods, better defocus estimation, and better alignments of the tilt-series and subtomograms. To quantify the importance of each contribution, we have split the full process from data collection to reconstruction into different steps. For the purpose of evaluation we have acquired tilt-series of ribosomes in such a way that we could precisely determine the defocus of each macromolecule. Then, we simulated tilt-series using the InSilicoTEM package and applied tomogram reconstruction and subtomogram averaging. Through large scale simulations under different conditions and parameter settings we find that tilt-series alignment is the resolution limiting factor for our experimental data. Using simulations, we find that when this alignment inaccuracy is alleviated, tilted CTF correction improves the final resolution, or equivalently, the same resolution can be achieved using less particles. Furthermore, we predict from which resolution onwards better CIF correction and defocus estimation methods are required. We obtain a final average using 3198 ribosomes with a resolution of 2.2 nm on the experimental data. Our simulations suggest that with the same number of particles a resolution of 1.2 nm could be achieved by improving the tilt-series alignment. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 35 条
  • [1] Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles
    Bai, Xiao-chen
    Fernandez, Israel S.
    McMullan, Greg
    Scheres, Sjors H. W.
    [J]. ELIFE, 2013, 2
  • [2] Protein Secondary Structure Determination by Constrained Single-Particle Cryo-Electron Tomography
    Bartesaghi, Alberto
    Lecumberry, Federico
    Sapiro, Guillermo
    Subramaniam, Sriram
    [J]. STRUCTURE, 2012, 20 (12) : 2003 - 2013
  • [3] Structure and assembly of immature HIV
    Briggs, J. A. G.
    Riches, J. D.
    Glass, B.
    Bartonova, V.
    Zanetti, G.
    Kraeusslich, H.-G.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (27) : 11090 - 11095
  • [4] Beam-induced motion of vitrified specimen on holey carbon film
    Brilot, Axel F.
    Chen, James Z.
    Cheng, Anchi
    Pan, Junhua
    Harrison, Stephen C.
    Potter, Clinton S.
    Carragher, Bridget
    Henderson, Richard
    Grigorieff, Nikolaus
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) : 630 - 637
  • [5] Movies of Ice-Embedded Particles Enhance Resolution in Electron Cryo-Microscopy
    Campbell, Melody G.
    Cheng, Anchi
    Brilot, Axel F.
    Moeller, Arne
    Lyumkis, Dmitry
    Veesler, David
    Pan, Junhua
    Harrison, Stephen C.
    Potter, Clinton S.
    Carragher, Bridget
    Grigorieff, Nikolaus
    [J]. STRUCTURE, 2012, 20 (11) : 1823 - 1828
  • [6] Fast and accurate reference-free alignment of subtomograms
    Chen, Yuxiang
    Pfeffer, Stefan
    Hrabe, Thomas
    Schuller, Jan Michael
    Foerster, Friedrich
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2013, 182 (03) : 235 - 245
  • [7] Simplified screening for the detection of soluble fusion constructs expressed in E-coli using a modular set of vectors -: art. no. 34
    Dümmler, A
    Lawrence, AM
    de Marco, A
    [J]. MICROBIAL CELL FACTORIES, 2005, 4 (1)
  • [8] Unraveling the structure of membrane proteins in situ by transfer function corrected cryo-electron tomography
    Eibauer, Matthias
    Hoffmann, Christian
    Plitzko, Juergen M.
    Baumeister, Wolfgang
    Nickell, Stephan
    Engelhardt, Harald
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2012, 180 (03) : 488 - 496
  • [9] PRIME: Probabilistic Initial 3D Model Generation for Single-Particle Cryo-Electron Microscopy
    Elmlund, Hans
    Elmlund, Dominika
    Bengio, Samy
    [J]. STRUCTURE, 2013, 21 (08) : 1299 - 1306
  • [10] Fechter Pierre, 2009, V540, P247, DOI 10.1007/978-1-59745-558-9_18