Influence of temperature on the dimensional stability of an addition silicone

被引:0
作者
Almeida, Carlos F. [1 ]
Dantas, Filipe [2 ]
Portela, Ana [2 ]
Vasconcelos, Mario [2 ]
Campos, J. C. Reis [2 ]
机构
[1] Portuguese Catholic Univ, Inst Hlth Sci, Viseu, Portugal
[2] Univ Porto, Fac Dent Med, Porto, Portugal
来源
BIODENTAL ENGINEERING V | 2019年
关键词
IMPRESSION MATERIALS; POLYETHER; ACCURACY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Dental Impression Materials are used in many stages of dental prosthesis construction and can be classified as: rigid, thermoplastic, or elastic. Elastic Materials are those that remain in an elastic state after removal of the oral cavity. Addition silicones are one of the most utilized in the elastic group. Thus being, the aim of this study is to assess the influence of temperature on the dimensional stability of an addition silicone. Six casts of specimen metal were done and pairs of samples were submitted to warm (60 degrees C), cold (10 degrees C) and environmental temperature (22 degrees C). They were then measured at intervals of 1, 5, 24 and 48 hours after the printing. We experimentally proved that silicone at 60 degrees C showed the highest volumetric contraction, comparing to a slight shrinkage registered at the temperature of 22 degrees C; at the lowest temperature (10 degrees C) there were practically no dimensional changes to the models used. As temperature interferes with the dimensional stability of silicone, you need to manipulate and store it under stable conditions to ensure reliability. The shift from cast to plaster must be made as soon as possible (1 hour). When such is not possible, the best method to ensure the preservation of the dimensional stability of an impression is to place it in a refrigerated environment (for no longer than five hours).
引用
收藏
页码:11 / 13
页数:3
相关论文
共 16 条
  • [1] Amin Wala M, 2009, J Clin Med Res, V1, P81, DOI 10.4021/jocmr2009.04.1235
  • [2] Temperature effects on the rheological properties of current polyether and polysiloxane impression materials during setting
    Berg, JC
    Johnson, GH
    Lepe, X
    Adán-Plaza, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (02) : 150 - 161
  • [3] Factors affecting the accuracy of elastometric impression materials
    Chen, SY
    Liang, WM
    Chen, FN
    [J]. JOURNAL OF DENTISTRY, 2004, 32 (08) : 603 - 609
  • [4] The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials
    Corso, M
    Abanomy, A
    Di Canzio, J
    Zurakowski, D
    Morgano, SM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (06) : 626 - 631
  • [5] Endo T, 2006, QUINTESSENCE INT, V37, P47
  • [6] DIMENSIONAL STABILITY OF SILICONE-BASED IMPRESSION MATERIALS
    FANO, V
    GENNARI, PU
    ORTALLI, I
    [J]. DENTAL MATERIALS, 1992, 8 (02) : 105 - 109
  • [7] Faria Adriana Cláudia Lapria, 2008, Braz. oral res., V22, P293
  • [8] Forrester-Baker L, 2005, Eur J Prosthodont Restor Dent, V13, P69
  • [9] Giordano R 2nd, 2000, Gen Dent, V48, P510
  • [10] Hassan A. K., 2006, Eastern Mediterranean Health Journal, V12, P632