Highly sensitive and selective acute myocardial infarction detection using aptamer-tethered MoS2 nanoflower and screen-printed electrodes

被引:29
作者
Vasudevan, Mugashini [1 ,2 ]
Tai, Melvin J. Y. [1 ,2 ]
Perumal, Veeradasan [1 ,2 ]
Gopinath, Subash C. B. [3 ,4 ]
Murthe, Satisvar Sundera [1 ,5 ]
Ovinis, Mark [2 ]
Mohamed, Norani Muti [1 ,5 ]
Joshi, Nirav [6 ,7 ]
机构
[1] Univ Teknol PETRONAS, Ctr Innovat Nanostruct & Nanodevices COINN, Seri Iskandar 32610, Perak Darul Rid, Malaysia
[2] Univ Teknol PETRONAS, Dept Mech Engn, Seri Iskandar, Perak Darul Rid, Malaysia
[3] Univ Malaysia Perlis, Inst Nano Elect Engn, Kangar, Perlis, Malaysia
[4] Univ Malaysia Perlis, Sch Bioproc Engn, Arau, Perlis, Malaysia
[5] Univ Teknol PETRONAS, Dept Fundamental & Appl Sci, Seri Iskandar, Perak Darul Rid, Malaysia
[6] Univ Sao Paulo, Sao Carlos Inst Phys, Sao Carlos, SP, Brazil
[7] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
基金
巴西圣保罗研究基金会;
关键词
acute myocardial infarction; aptasensor; biomarker; molybdenum disulfide; troponin I; CARDIAC TROPONIN-I; SELF-ASSEMBLED NANOSHEETS; PERFORMANCE; FABRICATION; BIOSENSOR; HYBRID;
D O I
10.1002/bab.2060
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Acute myocardial infarction (AMI) is one of the leading causes of death worldwide. Cardiac troponin I (cTn1) is a commonly used biomarker for the diagnosis of AMI. Although there are various detection methods for the rapid detection of cTn1 such as optical, electrochemical, and acoustic techniques, electrochemical aptasensing techniques are commonly used because of their ease of handling, portability, and compactness. In this study, an electrochemical cTn1 biosensor, MoS2 nanoflowers on screen-printed electrodes assisted by aptamer, was synthesized using hydrothermal technique. Field emission scanning electron microscopy revealed distinct 2D nanosheets and jagged flower-like 3D MoS2 nanoflower structure, with X-ray diffraction analysis revealing well-stacked MoS(2 )layers. Voltammetry aptasensing of cTn1 ranges from 10 fM to 1 nM, with a detection limit at 10 fM and a sensitivity of 0.10 nA mu M-1 cm(-2). This is a similar to fivefold improvement in selectivity compared with the other proteins and human serum. This novel aptasensor retained 90% of its biosensing activity after 6 weeks with a 4.3% RSD and is a promising high-performance biosensor for detecting cTn1.
引用
收藏
页码:1386 / 1395
页数:10
相关论文
共 33 条
[1]  
[Anonymous], 2015, SCI REP
[2]   Electrochemical Impedance Biosensor for the Determination of Lipopolysaccharide Using Peptide as the Recognition Molecule [J].
Fan, Xuemei ;
Li, Zhejian ;
Wang, Shumin ;
Liu, Lei ;
Liu, Ping ;
Chen, Fengying ;
Zheng, Xingwang .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2019, 30 (08) :1762-1768
[3]   Aptamer-based determination of ATP by using a functionalized impedimetric nanosensor and mediation by a triangular junction transducer [J].
Gopinath, Subash C. B. ;
Perumal, Veeradasan ;
Balakrishnan, S. R. ;
Arshad, M. K. Md ;
Lakshmipriya, Thangavel ;
Haarindraprasad, R. ;
Hashim, Uda .
MICROCHIMICA ACTA, 2017, 184 (11) :4425-4431
[4]   Fabrication of interdigitated high-performance zinc oxide nanowire modified electrodes for glucose sensing [J].
Haarindraprasad, R. ;
Hashim, Uda ;
Gopinath, Subash C. B. ;
Perumal, Veeradasan ;
Liu, Wei-Wen ;
Balakrishnan, S. R. .
ANALYTICA CHIMICA ACTA, 2016, 925 :70-81
[5]  
Hospital S., 2018, J MED INVESTIG, V53, P34, DOI DOI 10.1021/acs.analchem.5b02312
[6]   Fabrication of 3D Hierarchical MoS2/Polyaniline and MoS2/C Architectures for Lithium-Ion Battery Applications [J].
Hu, Lianren ;
Ren, Yumei ;
Yang, Hongxia ;
Xu, Qun .
ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (16) :14644-14652
[7]   Preparation of carbon coated MoS2 flower-like nanostructure with self-assembled nanosheets as high-performance lithium-ion battery anodes [J].
Hu, Shan ;
Chen, Wen ;
Zhou, Jing ;
Yin, Fei ;
Uchaker, Evan ;
Zhang, Qifeng ;
Cao, Guozhong .
JOURNAL OF MATERIALS CHEMISTRY A, 2014, 2 (21) :7862-7872
[8]   Highly sensitive amperometric detection of cardiac troponin I using sandwich aptamers and screen-printed carbon electrodes [J].
Jo, Hunho ;
Her, Jin ;
Lee, Heehyun ;
Shim, Yoon-Bo ;
Ban, Changill .
TALANTA, 2017, 165 :442-448
[9]   Electrochemical Aptasensor of Cardiac Troponin I for the Early Diagnosis of Acute Myocardial Infarction [J].
Jo, Hunho ;
Gu, Hyunwoo ;
Jeon, Weejeong ;
Youn, Hyungjun ;
Her, Jin ;
Kim, Seong-Kyeong ;
Lee, Jeongbong ;
Shin, Jae Ho ;
Ban, Changill .
ANALYTICAL CHEMISTRY, 2015, 87 (19) :9869-9875
[10]   Aptamer-Functionalized Hybrid Carbon Nanofiber FET-Type Electrode for a Highly Sensitive and Selective Platelet-Derived Growth Factor Biosensor [J].
Jun, Jaemoon ;
Lee, Jun Seop ;
Shin, Dong Hoon ;
Jang, Jyongsik .
ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (16) :13859-13865