Spatial analysis of CO poisoning in high temperature polymer electrolyte membrane fuel cells

被引:16
作者
Babu, Venkatesh K. P. [1 ]
Varghese, Geethu [1 ]
Joseph, Thadathil Varghese [1 ]
Chippar, Purushothama [2 ]
机构
[1] Deemed Univ, Dept Math, CHRIST, Bengaluru 560029, Karnataka, India
[2] Visvesvaraya Technol Univ, St Joseph Engn Coll, Dept Mech Engn, Vamanjoor 575028, Mangaluru, India
关键词
High temperature-proton exchange membrane fuel cell; CO poisoning; Segmented cell; Current distribution; Numerical modeling;
D O I
10.1016/j.ijhydene.2020.12.001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The improved tolerance of the High Temperature-Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) to CO allows the use of reformate as an anode feed. However, the presence of several per cent of CO in the reformate, which is inevitable particularly in on-board reformation in automobiles, which otherwise demands complex systems to keep the CO level very low, will significantly lower the cell performance, especially when the HT-PEMFC is operated at 160 degrees C or below. In this study, a three-dimensional, non-isothermal numerical model is developed and applied to a single straight-channel HT-PEMFC geometry. The model is validated against the experimental data for a broad range of current densities at different CO concentration and operating temperatures. A significant spatial variation in current density distribution is observed in the membrane because the CO sorption is a spatially non-homogeneous process depending on local operating conditions and dilution of the H-2 stream. To investigate the local spatial effects on HT-PEMFC operation, the model is applied to a real cell of size 49.4 cm(2) with an 8-pass serpentine flow-field at the anode and the cathode. The membrane and anode catalyst layer are segmented into 5 x 5 array to investigate the spatial resolution of the polarization curves, H-2 concentration, current density, and anode polarization loss. The simulation results show that the presence of CO in the anode feed reduces cell performance, however, the results reveal that uniformity in current density distribution in the membrane improves when the cell is operated in potentiostatic mode. The results are discussed in detail with the help of several line plots and multi-dimensional contours. The study also emphasizes on the importance of optimizing the reformate anode feed rate to improve cell performance. (c) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:8179 / 8196
页数:18
相关论文
共 47 条
[11]   Three-dimensional non-isothermal modeling of a phosphoric acid-doped polybenzimidazole (PBI) membrane fuel cell [J].
Chippar, Purushothama ;
Ju, Hyunchul .
SOLID STATE IONICS, 2012, 225 :30-39
[12]   Experimental evaluation of CO poisoning on the performance of a high temperature proton exchange membrane fuel cell [J].
Das, Susanta K. ;
Reis, Antonio ;
Berry, K. J. .
JOURNAL OF POWER SOURCES, 2009, 193 (02) :691-698
[13]   Experimental investigation of CO tolerance in high temperature PEM fuel cells [J].
Devrim, Yilser ;
Albostan, Ayhan ;
Devrim, Huseyin .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (40) :18672-18681
[14]   PERFORMANCE STUDY OF A FUEL-CELL PT-ON-C ANODE IN PRESENCE OF CO AND CO2, AND CALCULATION OF ADSORPTION PARAMETERS FOR CO POISONING [J].
DHAR, HP ;
CHRISTNER, LG ;
KUSH, AK ;
MARU, HC .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (08) :1574-1582
[15]   Components for PEM fuel cell systems using hydrogen and CO containing fuels [J].
Divisek, J ;
Oetjen, HF ;
Peinecke, V ;
Schmidt, VM ;
Stimming, U .
ELECTROCHIMICA ACTA, 1998, 43 (24) :3811-3815
[16]   H-2 AND CO ELECTROOXIDATION ON WELL-CHARACTERIZED PT, RU, AND PT-RU .2. ROTATING DISK ELECTRODE STUDIES OF CO/H-2 MIXTURES AT 62-DEGREES-C [J].
GASTEIGER, HA ;
MARKOVIC, NM ;
ROSS, PN .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (45) :16757-16767
[17]   A NEW APPROACH TO THE PROBLEM OF CARBON-MONOXIDE POISONING IN FUEL-CELLS OPERATING AT LOW-TEMPERATURES [J].
GOTTESFELD, S ;
PAFFORD, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (10) :2651-2652
[18]   Novel techniques of oxygen bleeding for polymer electrolyte fuel cells under impure anode feeding and poisoning condition: A computational study using OpenFOAM® [J].
Hafttananian, M. ;
Ramiar, A. ;
Ranjbar, A. A. .
ENERGY CONVERSION AND MANAGEMENT, 2016, 122 :564-579
[19]   Poison mitigation strategies for the use of impure hydrogen in electrochemical hydrogen pumps and fuel cells [J].
Jackson, C. ;
Raymakers, L. F. J. M. ;
Mulder, M. J. J. ;
Kucernak, A. R. J. .
JOURNAL OF POWER SOURCES, 2020, 472
[20]   Assessment of the performance of a PEMFC in the presence of CO [J].
Jiménez, S ;
Soler, J ;
Valenzuela, RX ;
Daza, L .
JOURNAL OF POWER SOURCES, 2005, 151 :69-73