Optimization of anterior eye fluorescein viewing

被引:40
作者
Peterson, Rachael C. [1 ]
Wolffsohn, James S. [1 ]
Fowler, Colin W. [1 ]
机构
[1] Aston Univ, Sch Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
关键词
D O I
10.1016/j.ajo.2006.04.062
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To optimize anterior eye fluorescein viewing and image capture. center dot DESIGN: Prospective experimental investigation. center dot METHODS: The spectral radiance of ten different models of slit-lamp blue luminance and the spectral transmission of three barrier filters were measured. Optimal clinical instillation of fluorescein was evaluated by a comparison of four different instillation methods of fluorescein into 10 subjects. Two methods used a floret, and two used minims of different concentration. The resulting fluorescence was evaluated for quenching effects and efficiency over time. center dot RESULTS: Spectral radiance of the blue illumination typically had an average peak at 460 nm. Comparison between three slit-lamps of the same model showed a similar spectral radiance distribution. Of the slit,lamps examined, 8.3% to 50.6% of the illumination output was optimized for > 80% fluorescein excitation, and 1.2% to 23.5% of the illumination overlapped with that emitted by the fluorophore. The barrier filters had an average cut-off at 510 to 520 run. Quenching was observed for all methods of fluorescein instillation. The moistened floret and the 1% minim reached a useful level of fluorescence in on average similar to 20s (similar to 2.5x faster than the saturated floret and 2% minim) and this lasted for similar to 160 seconds. center dot CONCLUSIONS: Most slit-lamps' blue light and yellow barrier filters are not optimal for fluorescein viewing and capture. Instillation of fluorescein using a moistened floret or 1% minim seems most clinically appropriate as lower quantities and concentrations of fluorescein improve the efficiency of clinical examination. (Am J Ophthalmol 2006; 142:572-575. (c) 2006 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:572 / 575
页数:4
相关论文
共 8 条
[1]   POTENTIAL HAZARDS FROM SPECIFIC OPHTHALMIC DEVICES [J].
CALKINS, JL ;
HOCHHEIMER, BF ;
DANNA, SA .
VISION RESEARCH, 1980, 20 (12) :1039-1053
[3]   A standardized visual scale for evaluation of tear fluorescein clearance [J].
Macri, A ;
Rolando, M ;
Pflugfelder, S .
OPHTHALMOLOGY, 2000, 107 (07) :1338-1343
[4]   Do blue light filters confer protection against age-related macular degeneration? [J].
Margrain, TH ;
Boulton, M ;
Marshall, J ;
Sliney, DH .
PROGRESS IN RETINAL AND EYE RESEARCH, 2004, 23 (05) :523-531
[5]   LIGHT-SOURCES FOR FLUORESCEIN FLUOROPHOTOMETRY [J].
MCLAREN, JW ;
BRUBAKER, RF .
APPLIED OPTICS, 1983, 22 (18) :2897-2905
[6]  
NORN MS, 1988, ACTA OPHTHALMOL, V66, P485
[7]   FLUORESCEIN - PHYSICOCHEMICAL FACTORS AFFECTING ITS FLUORESCENCE [J].
ROMANCHUK, KG .
SURVEY OF OPHTHALMOLOGY, 1982, 26 (05) :269-283
[8]   Quantitating fluorescence intensity from fluorophores: Practical use of MESF values [J].
Wang, LL ;
Gaigalas, AK ;
Abbasi, F ;
Marti, GE ;
Vogt, RF ;
Schwartz, A .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2002, 107 (04) :339-353