Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)

被引:23
作者
Zhou, Ruixi [1 ]
Yang, Yang [2 ,3 ,4 ]
Mathew, Roshin C. [2 ,5 ]
Mugler, John P., III [1 ,2 ,5 ]
Weller, Daniel S. [6 ]
Kramer, Christopher M. [2 ,5 ]
Ahmed, Abdul Haseeb [7 ]
Jacob, Mathews [7 ]
Salerno, Michael [2 ,5 ]
机构
[1] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia Hlth Syst, Cardiovasc Div, Dept Med, Charlottesville, VA USA
[3] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY 10029 USA
[4] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[5] Univ Virginia Hlth Syst, Radiol & Med Imaging, Charlottesville, VA USA
[6] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA USA
[7] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
cardiac MRI; golden angle; low-rank and sparse; motion correction; self-gating; spiral trajectory; STATE FREE PRECESSION; ACCELERATED DYNAMIC MRI; HEART CORONARY MRA; WHOLE-HEART; MAGNETIC-RESONANCE; RADIAL SSFP; INTERFERENCE; COMPENSATION; SUPPRESSION; SPARSITY;
D O I
10.1002/mrm.27763
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging. MethodsCine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 x 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence. ResultsThe self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique. ConclusionSPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
引用
收藏
页码:706 / 720
页数:15
相关论文
共 32 条
[31]   Free-running 3D whole-heart T1 and T2 mapping and cine MRI using low-rank reconstruction with non-rigid cardiac motion correction [J].
Phair, Andrew ;
Cruz, Gastao ;
Qi, Haikun ;
Botnar, Rene M. ;
Prieto, Claudia .
MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) :217-232
[32]   How low can we go? The effect of acquisition duration on cardiac volume and function measurements in free-running cardiac and respiratory motion-resolved five-dimensional whole-heart cine magnetic resonance imaging at 1.5T [J].
Holtackers, Robert J. ;
Ogier, Augustin C. ;
Romanin, Ludovica ;
Tenisch, Estelle ;
Quesada, Isabel Monton ;
van Heeswijk, Ruud B. ;
Roy, Christopher W. ;
Yerly, Jerome ;
Prsa, Milan ;
Stuber, Matthias .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2025, 27 (01)