Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)

被引:23
作者
Zhou, Ruixi [1 ]
Yang, Yang [2 ,3 ,4 ]
Mathew, Roshin C. [2 ,5 ]
Mugler, John P., III [1 ,2 ,5 ]
Weller, Daniel S. [6 ]
Kramer, Christopher M. [2 ,5 ]
Ahmed, Abdul Haseeb [7 ]
Jacob, Mathews [7 ]
Salerno, Michael [2 ,5 ]
机构
[1] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia Hlth Syst, Cardiovasc Div, Dept Med, Charlottesville, VA USA
[3] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY 10029 USA
[4] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[5] Univ Virginia Hlth Syst, Radiol & Med Imaging, Charlottesville, VA USA
[6] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA USA
[7] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
cardiac MRI; golden angle; low-rank and sparse; motion correction; self-gating; spiral trajectory; STATE FREE PRECESSION; ACCELERATED DYNAMIC MRI; HEART CORONARY MRA; WHOLE-HEART; MAGNETIC-RESONANCE; RADIAL SSFP; INTERFERENCE; COMPENSATION; SUPPRESSION; SPARSITY;
D O I
10.1002/mrm.27763
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging. MethodsCine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 x 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence. ResultsThe self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique. ConclusionSPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
引用
收藏
页码:706 / 720
页数:15
相关论文
共 32 条
[11]   Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T [J].
Takakado, Masahiro ;
Kido, Tomoyuki ;
Ogawa, Ryo ;
Takimoto, Yoshihiro ;
Tokuda, Tsuyoshi ;
Tanabe, Yuki ;
Kawaguchi, Naoto ;
Pang, Jianing ;
Komori, Yoshiaki ;
Kido, Teruhito .
JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (02) :142-152
[12]   Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T [J].
Masahiro Takakado ;
Tomoyuki Kido ;
Ryo Ogawa ;
Yoshihiro Takimoto ;
Tsuyoshi Tokuda ;
Yuki Tanabe ;
Naoto Kawaguchi ;
Jianing Pang ;
Yoshiaki Komori ;
Teruhito Kido .
Japanese Journal of Radiology, 2023, 41 :142-152
[13]   Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging [J].
Merlocco, Anthony ;
Olivieri, Laura ;
Kellman, Peter ;
Xue, Hui ;
Cross, Russell .
PEDIATRIC CARDIOLOGY, 2019, 40 (01) :79-88
[14]   Free-breathing T2*mapping using respiratory motion corrected averaging [J].
Kellman, Peter ;
Xue, Hui ;
Spottiswoode, Bruce S. ;
Sandino, Christopher M. ;
Hansen, Michael S. ;
Abdel-Gadir, Amna ;
Treibel, Thomas A. ;
Rosmini, Stefania ;
Mancini, Christine ;
Bandettini, W. Patricia ;
McGill, Laura-Ann ;
Gatehouse, Peter ;
Moon, James C. ;
Pennell, Dudley J. ;
Arai, Andrew E. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[15]   Free-breathing T2* mapping using respiratory motion corrected averaging [J].
Peter Kellman ;
Hui Xue ;
Bruce S Spottiswoode ;
Christopher M Sandino ;
Michael S Hansen ;
Amna Abdel-Gadir ;
Thomas A Treibel ;
Stefania Rosmini ;
Christine Mancini ;
W Patricia Bandettini ;
Laura-Ann McGill ;
Peter Gatehouse ;
James C Moon ;
Dudley J Pennell ;
Andrew E Arai .
Journal of Cardiovascular Magnetic Resonance, 17
[16]   Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging [J].
Anthony Merlocco ;
Laura Olivieri ;
Peter Kellman ;
Hui Xue ;
Russell Cross .
Pediatric Cardiology, 2019, 40 :79-88
[17]   Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging [J].
Cross, Russell ;
Olivieri, Laura ;
O'Brien, Kendall ;
Kellman, Peter ;
Xue, Hui ;
Hansen, Michael .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
[18]   Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging [J].
Russell Cross ;
Laura Olivieri ;
Kendall O’Brien ;
Peter Kellman ;
Hui Xue ;
Michael Hansen .
Journal of Cardiovascular Magnetic Resonance, 18
[19]   Non-rigid motion-corrected free-breathing 3D myocardial Dixon LGE imaging in a clinical setting [J].
Zeilinger, Martin Georg ;
Kunze, Karl-Philipp ;
Munoz, Camila ;
Neji, Radhouene ;
Schmidt, Michaela ;
Croisille, Pierre ;
Heiss, Rafael ;
Wuest, Wolfgang ;
Uder, Michael ;
Botnar, Rene Michael ;
Treutlein, Christoph ;
Prieto, Claudia .
EUROPEAN RADIOLOGY, 2022, 32 (07) :4340-4351
[20]   Effect of respiratory motion on free-breathing 3D stack-of-radial liver R2*relaxometry and improved quantification accuracy using self-gating [J].
Zhong, Xiaodong ;
Armstrong, Tess ;
Nickel, Marcel D. ;
Kannengiesser, Stephan Ar ;
Pan, Li ;
Dale, Brian M. ;
Deshpande, Vibhas ;
Kiefer, Berthold ;
Wu, Holden H. .
MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) :1964-1978