Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)

被引:23
|
作者
Zhou, Ruixi [1 ]
Yang, Yang [2 ,3 ,4 ]
Mathew, Roshin C. [2 ,5 ]
Mugler, John P., III [1 ,2 ,5 ]
Weller, Daniel S. [6 ]
Kramer, Christopher M. [2 ,5 ]
Ahmed, Abdul Haseeb [7 ]
Jacob, Mathews [7 ]
Salerno, Michael [2 ,5 ]
机构
[1] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia Hlth Syst, Cardiovasc Div, Dept Med, Charlottesville, VA USA
[3] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY 10029 USA
[4] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[5] Univ Virginia Hlth Syst, Radiol & Med Imaging, Charlottesville, VA USA
[6] Univ Virginia, Dept Elect & Comp Engn, Charlottesville, VA USA
[7] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
cardiac MRI; golden angle; low-rank and sparse; motion correction; self-gating; spiral trajectory; STATE FREE PRECESSION; ACCELERATED DYNAMIC MRI; HEART CORONARY MRA; WHOLE-HEART; MAGNETIC-RESONANCE; RADIAL SSFP; INTERFERENCE; COMPENSATION; SUPPRESSION; SPARSITY;
D O I
10.1002/mrm.27763
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging. MethodsCine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 x 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence. ResultsThe self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique. ConclusionSPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
引用
收藏
页码:706 / 720
页数:15
相关论文
共 32 条
  • [1] Dual-excitation flip-angle simultaneous cine and T1 mapping using spiral acquisition with respiratory and cardiac self-gating
    Zhou, Ruixi
    Weller, Daniel S.
    Yang, Yang
    Wang, Junyu
    Jeelani, Haris
    Mugler, John P.
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 82 - 96
  • [2] Motion Correction Using Coil Arrays (MOCCA) for Free-Breathing Cardiac Cine MRI
    Hu, Peng
    Hong, Susie
    Moghari, Mehdi H.
    Goddu, Beth
    Goepfert, Lois
    Kissinger, Kraig V.
    Hauser, Thomas H.
    Manning, Warren J.
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 467 - 475
  • [3] Free-Breathing Variable Flip Angle Balanced SSFP Cardiac Cine Imaging with Reduced SAR at 3T
    Srinivasan, Subashini
    Kroeker, Randall M.
    Gabriel, Simon
    Plotnik, Adam
    Godinez, Sergio R.
    Hu, Peng
    Halnon, Nancy
    Finn, J. Paul
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1210 - 1216
  • [4] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    李硕
    王磊
    朱艳春
    杨洁
    谢耀钦
    付楠
    王乙
    高嵩
    Chinese Physics B, 2016, (12) : 547 - 552
  • [5] Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging
    Li, Shuo
    Wang, Lei
    Zhu, Yan-Chun
    Yang, Jie
    Xie, Yao-Qin
    Fu, Nan
    Wang, Yi
    Gao, Song
    CHINESE PHYSICS B, 2016, 25 (12)
  • [6] High efficiency free-breathing 3D thoracic aorta vessel wall imaging using self-gating image reconstruction
    Shi, Caiyun
    Liang, Dong
    Wang, Haifeng
    Zhu, Yanjie
    MAGNETIC RESONANCE IMAGING, 2024, 107 : 80 - 87
  • [7] Validation of cardiac magnetic-resonance-derived left ventricular strain measurements from free-breathing motion-corrected cine imaging
    Merlocco, Anthony
    Cross, Russell R.
    Kellman, Peter
    Xue, Hui
    Olivieri, Laura
    PEDIATRIC RADIOLOGY, 2019, 49 (01) : 68 - 75
  • [8] Validation of cardiac magnetic-resonance-derived left ventricular strain measurements from free-breathing motion-corrected cine imaging
    Anthony Merlocco
    Russell R. Cross
    Peter Kellman
    Hui Xue
    Laura Olivieri
    Pediatric Radiology, 2019, 49 : 68 - 75
  • [9] Respiratory and Cardiac Self-Gated Free-Breathing Cardiac CINE Imaging With Multiecho 3D Hybrid Radial SSFP Acquisition
    Liu, Jing
    Spincemaille, Pascal
    Codella, Noel C. F.
    Nguyen, Thanh D.
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1230 - 1237
  • [10] Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging
    spincemaille, Pascal
    Liu, Jing
    Thanh Nguyen
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 861 - 868