Patient-specific finite element modeling of respiratory lung motion using 4D CT image data

被引:115
作者
Werner, Rene [1 ]
Ehrhardt, Jan [1 ]
Schmidt, Rainer [2 ]
Handels, Heinz [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Med Informat, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Radiotherapy & Radiooncol, D-20246 Hamburg, Germany
关键词
biomechanics; computerised tomography; finite element analysis; lung; medical image processing; optimisation; pneumodynamics; radiation therapy; tumours; INSPIRATION BREATH-HOLD; ORGAN MOTION; DEFORMABLE REGISTRATION; RADIATION-THERAPY; TECHNICAL NOTE; TUMOR MOTION; CANCER; RECONSTRUCTION; RADIOTHERAPY; NONLINEARITY;
D O I
10.1118/1.3101820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Development and optimization of methods for adequately accounting for respiratory motion in radiation therapy of thoracic tumors require detailed knowledge of respiratory dynamics and its impact on corresponding dose distributions. Thus, computer aided modeling and simulation of respiratory motion have become increasingly important. In this article a biophysical approach for modeling respiratory lung motion is described: Major aspects of the process of lung ventilation are formulated as a contact problem of elasticity theory which is solved by finite element methods; lung tissue is assumed to be isotropic, homogeneous, and linearly elastic. A main focus of the article is to assess the impact of biomechanical parameters (values of elastic constants) on the modeling process and to evaluate modeling accuracy. Patient-specific models are generated based on 4D CT data of 12 lung tumor patients. Simulated motion patterns of inner lung landmarks are compared with corresponding motion patterns observed in the 4D CT data. Mean absolute differences between model-based predicted landmark motion and corresponding breathing-induced landmark displacements as observed in the CT data sets are in the order of 3 mm (end expiration to end inspiration) and 2 mm (end expiration to midrespiration). Modeling accuracy decreases with increasing tumor size both locally (landmarks close to tumor) and globally (landmarks in other parts of the lung). The impact of the values of the elastic constants appears to be small. Outcomes show that the modeling approach is an adequate strategy in predicting lung dynamics due to lung ventilation. Nevertheless, the decreased prediction quality in cases of large tumors demands further study of the influence of lung tumors on global and local lung elasticity properties.
引用
收藏
页码:1500 / 1511
页数:12
相关论文
共 50 条
  • [41] A patient-specific deep learning framework for 3D motion estimation and volumetric imaging during lung cancer radiotherapy
    Hindley, Nicholas
    Shieh, Chun-Chien
    Keall, Paul
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14)
  • [42] Patient-Specific Finite Element Modeling of the Whole Lumbar Spine Using Clinical Routine Multi-Detector Computed Tomography (MDCT) Data-A Pilot Study
    Rayudu, Nithin Manohar
    Subburaj, Karupppasamy
    Mohan, Rajesh Elara
    Sollmann, Nico
    Dieckmeyer, Michael
    Kirschke, Jan S.
    Baum, Thomas
    BIOMEDICINES, 2022, 10 (07)
  • [43] 4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT
    Nakagawa, Keiichi
    Haga, Akihiro
    Kida, Satoshi
    Masutani, Yoshitaka
    Yamashita, Hideomi
    Takahashi, Wataru
    Sakumi, Akira
    Saotome, Naoya
    Shiraki, Takashi
    Ohtomo, Kuni
    Iwai, Yoshio
    Yoda, Kiyoshi
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (01) : 152 - 156
  • [44] Generation of synthetic CT data using patient specific daily MR image data and image registration
    Kraus, Kim Melanie
    Jaekel, Oliver
    Niebuhr, Nina I.
    Pfaffenberger, Asja
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04) : 1358 - 1377
  • [45] 4D CT image artifacts affect local control in SBRT of lung and liver metastases
    Sentker, Thilo
    Schmidt, Vladimir
    Ozga, Ann-Kathrin
    Petersen, Cordula
    Madesta, Frederic
    Hofmann, Christian
    Werner, Rene
    Gauer, Tobias
    RADIOTHERAPY AND ONCOLOGY, 2020, 148 : 229 - 234
  • [46] Patient-specific quantification of respiratory motion-induced dose uncertainty for step-and-shoot IMRT of lung cancer
    Li, Heng
    Park, Peter
    Liu, Wei
    Matney, Jason
    Liao, Zhongxing
    Balter, Peter
    Li, Yupeng
    Zhang, Xiaodong
    Li, Xiaoqiang
    Zhu, X. Ronald
    MEDICAL PHYSICS, 2013, 40 (12)
  • [47] Respiratory motion-resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Park, Sung Eun
    Kim, Ho Cheol
    Menini, Anne
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 5130 - 5138
  • [48] Patient-specific finite element modeling of scoliotic curve progression using region-specific stress-modulated vertebral growth
    D'Andrea, Christian R.
    Samdani, Amer F.
    Balasubramanian, Sriram
    SPINE DEFORMITY, 2023, 11 (03) : 525 - 534
  • [49] Prediction of Collapse Using Patient-Specific Finite Element Analysis of Osteonecrosis of the Femoral Head
    Li, Tai-xian
    Huang, Ze-qing
    Li, Yan
    Xue, Zhi-peng
    Sun, Ji-gao
    Gao, Huan-huan
    He, Hai-jun
    Chen, Wei-heng
    ORTHOPAEDIC SURGERY, 2019, 11 (05) : 794 - 800
  • [50] Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo
    McGurk, Ross
    Seco, Joao
    Riboldi, Marco
    Wolfgang, John
    Segars, Paul
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) : 1475 - 1490