Hyperpolarized noble gas magnetic resonance imaging of the animal lung: Approaches and applications

被引:23
|
作者
Santyr, Giles E. [1 ,2 ,3 ]
Lam, Wilfred W. [4 ]
Parra-Robles, Juan M. [5 ]
Taves, Timothy M. [1 ,2 ]
Ouriadov, Alexei V. [1 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
[3] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON N6A 5A5, Canada
[4] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[5] Univ Sheffield, Acad Unit Radiol, Sheffield S10 2JF, S Yorkshire, England
基金
加拿大自然科学与工程研究理事会;
关键词
biomagnetism; biomedical MRI; diffusion; diseases; lung; magnetisation; SPATIALLY-RESOLVED MEASUREMENTS; OXYGEN PARTIAL-PRESSURE; HE-3; DIFFUSION; RAT LUNG; IN-VIVO; AIRWAY HYPERRESPONSIVENESS; REGIONAL VENTILATION; TIME-COURSE; MRI; METHACHOLINE;
D O I
10.1063/1.3112143
中图分类号
O59 [应用物理学];
学科分类号
摘要
Hyperpolarized noble gas (HNG) magnetic resonance (MR) imaging is a very promising noninvasive tool for the investigation of animal models of lung disease, particularly to follow longitudinal changes in lung function and anatomy without the accumulated radiation dose associated with x rays. The two most common noble gases for this purpose are He-3 (helium 3) and Xe-129 (xenon 129), the latter providing a cost-effective approach for clinical applications. Hyperpolarization is typically achieved using spin-exchange optical pumping techniques resulting in similar to 10 000-fold improvement in available magnetization compared to conventional Boltzmann polarizations. This substantial increase in polarization allows high spatial resolution (< 1 mm) single-slice images of the lung to be obtained with excellent temporal resolution (< 1 s). Complete three-dimensional images of the lungs with 1 mm slice thickness can be obtained within reasonable breath-hold intervals (< 20 s). This article provides an overview of the current methods used in HNG MR imaging with an emphasis on ventilation studies in animals. Special MR hardware and software considerations are described in order to use the strong but nonrecoverable magnetization as efficiently as possible and avoid depolarization primarily by molecular oxygen. Several applications of HNG MR imaging are presented, including measurement of gross lung anatomy (e.g., airway diameters), microscopic anatomy (e.g., apparent diffusion coefficient), and a variety of functional parameters including dynamic ventilation, alveolar oxygen partial pressure, and xenon diffusing capacity.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129
    Mugler, John P., III
    Altes, Talissa A.
    Ruset, Iulian C.
    Dregely, Isabel M.
    Mata, Jaime F.
    Miller, G. Wilson
    Ketel, Stephen
    Ketel, Jeffrey
    Hersman, F. William
    Ruppert, Kai
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (50) : 21707 - 21712
  • [12] A Systematic Review of the Variability of Ventilation Defect Percent Generated From Hyperpolarized Noble Gas Pulmonary Magnetic Resonance Imaging
    Diamond, Vanessa M.
    Bell, Laura C.
    Bone, Jeffrey N.
    Driehuys, Bastiaan
    Menchaca, Martha
    Santyr, Giles
    Svenningsen, Sarah
    Thomen, Robert P.
    Marshall, Helen
    Smith, Laurie J.
    Collier, Guilhem J.
    Wild, Jim M.
    Woods, Jason C.
    Fain, Sean B.
    Eddy, Rachel L.
    Rayment, Jonathan H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025,
  • [13] New Developments in Imaging Idiopathic Pulmonary Fibrosis With Hyperpolarized Xenon Magnetic Resonance Imaging
    Mammarappallil, Joseph G.
    Rankine, Leith
    Wild, Jim M.
    Driehuys, Bastiaan
    JOURNAL OF THORACIC IMAGING, 2019, 34 (02) : 136 - 150
  • [14] Functional magnetic resonance imaging of the lung
    Mills, GH
    Wild, JM
    Eberle, B
    Van Beek, EJR
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (01) : 16 - 30
  • [15] Automated hyperpolarized 129 Xe gas generator for nuclear magnetic resonance spectroscopy and imaging applications
    Hattori, Mineyuki
    Hiraga, Takashi
    Homma, Kazuhiro
    Ohtake, Norio
    JOURNAL OF MAGNETIC RESONANCE OPEN, 2024, 20
  • [16] Regional ventilation mapping of the rat lung using hyperpolarized 129Xe magnetic resonance imaging
    Couch, Marcus J.
    Ouriadov, Alexei
    Santyr, Giles E.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1623 - 1631
  • [17] Assessment of in vitro vs. in vivo lung structure using hyperpolarized helium-3 diffusion magnetic resonance imaging
    Mata, Jaime F.
    Altes, Talissa A.
    Ruppert, Kai
    Hagspiel, Klaus D.
    Miller, Grady W.
    Brookeman, James R.
    Mugler, John P., III
    MAGNETIC RESONANCE IMAGING, 2009, 27 (06) : 845 - 851
  • [18] Assessment of Pulmonary Gas Transport in Rabbits Using Hyperpolarized Xenon-129 Magnetic Resonance Imaging
    Ruppert, Kai
    Hamedani, Hooman
    Amzajerdian, Faraz
    Xin, Yi
    Duncan, Ian F.
    Profka, Harrilla
    Siddiqui, Sarmad
    Pourfathi, Mehrdad
    Kadlecek, Stephen
    Rizi, Rahim R.
    SCIENTIFIC REPORTS, 2018, 8
  • [19] Hyperpolarized Gas MR Imaging Technique and Applications
    Roos, Justus E.
    McAdams, Holman P.
    Kaushik, S. Sivaram
    Driehuys, Bastiaan
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (02) : 217 - +
  • [20] Hyperpolarized Carbon-13 Magnetic Resonance Imaging: Technical Considerations and Clinical Applications
    Lai, Ying-Chieh
    Hsieh, Ching-Yi
    Juan, Yu -Hsiang
    Lu, Kuan-Ying
    Lee, Hsien-Ju
    Ng, Shu-Hang
    Wan, Yung-Liang
    Lin, Gigin
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (05) : 459 - 472