Correlation and regression between the breakdown voltage and pre-breakdown parameters of vacuum switching elements

被引:7
作者
Todorovic, Radomir [1 ,2 ]
Skataric, Dobrila [2 ]
Bajramovic, Zijad [3 ]
Stankovic, Koviljka [4 ]
机构
[1] Elect Power Ind Serbia, Belgrade, Serbia
[2] Univ Belgrade, Fac Mech Engn, Belgrade 11000, Serbia
[3] Univ Sarajevo, Fac Elect Engn, Sarajevo 71000, Bosnia & Herceg
[4] Univ Belgrade, Fac Elect Engn, Belgrade 11000, Serbia
关键词
Vacuum switching element; Switching operation; Pre-breakdown parameter; Breakdown voltage; Correlation; Regression; TIME ENLARGEMENT LAW; GAS;
D O I
10.1016/j.vacuum.2015.10.024
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper considers the influence of switching operations on the characteristics of vacuum switching elements. The following operations, all with circuit-making without current, have been taken into account: circuit-breaking without current, circuit-breaking with nominal current and circuit-breaking with short-circuit current. The influence of switching operations is examined for the random variables breakdown voltage (ac and pulse) and the pre-breakdown parameters V-4, V-5, and V-6. Parameters V-4, V-5, and V-6 represent the dc voltage at which the pre-breakdown current takes values of 10(-4), 10(-5), and 10(-6) A, respectively. Switching element characteristics after the switching operations are compared with the corresponding results obtained for switching element with conditioned contacts. The main result is an examination of the correlation and regression between the experimentally obtained breakdown voltage (ac and pulse) random variable and its corresponding pre-breakdown parameters V-4, V-5, and V-6, respectively. Statistical samples created by using this method do not require the repetition of switching operations and therefore the dielectric strength of the vacuum insulation is kept in its initial state. The examination is carried out on commercial vacuum switching elements with CuCr and CuBi contacts. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 50 条
[21]   Relation between breakdown voltage and current collapse in GaNFP-HEMTs [J].
Guo Liang-Liang ;
Qian, Feng ;
Ma Xiang-Bai ;
Yue, Hao ;
Jie, Liu .
ACTA PHYSICA SINICA, 2007, 56 (05) :2900-2904
[22]   BREAKDOWN VOLTAGES BETWEEN COAXIAL ELECTRODES WITH AXIAL MAGNETIC-FIELDS IN A VACUUM [J].
TAKEDA, S ;
HARA, M .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1992, 61 (03) :1119-1120
[23]   Pre-breakdown Phenomena and Influence of Aging Byproducts in Thermally Aged Low Pour Point Ester Fluids Under AC Stress [J].
Jayasree, T. ;
Rao, U. Mohan ;
Fofana, I ;
Brettschneider, S. ;
Celis, E. M. Rodriguez ;
Picher, P. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (05) :1563-1570
[24]   Adjustment Method of Optimum Breakdown Charge During Impulse Voltage Conditioning Process for Vacuum Interrupter [J].
Ma, Hui ;
Shen, Jingyu ;
Chi, Dianyu ;
Gao, Yulong ;
Li, Yuanzhao ;
Liu, Zhiyuan ;
Geng, Yingsan ;
Wang, Jianhua .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) :1463-1470
[25]   A Turnkey Solution for Computing the Static Breakdown Voltage in HVDC Applications Utilising Atmospheric Parameters [J].
Huber, Philipp ;
Jenau, Frank .
2024 59TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, UPEC, 2024,
[26]   Prediction of Breakdown Voltage of Long Air Gaps Under Switching Impulse Voltage Based on the ISSA-XGBoost Model [J].
Zeng, Zisheng ;
Song, Bin ;
Wu, Shaocheng ;
Li, Yongwen ;
Nie, Deyu ;
Wang, Linong .
ENERGIES, 2025, 18 (07)
[27]   Influence of Gap Between Electrode and Ceramic on Breakdown Voltage Under Atmospheric Conditions [J].
Xu, Ao ;
Yang, Lin ;
Shi, Yuanjie .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (02) :975-982
[28]   Influence of Grading Capacitances on the Lightning Impulse Breakdown Voltage of a Double-Break Vacuum Circuit Breaker [J].
Liu, Pei ;
Liu, Shaowei ;
Hong, Lixin ;
Yao, Xiaofei ;
Liu, Zhiyuan ;
Geng, Yingsan ;
Wang, Jianhua .
PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 1, 2018, :73-76
[29]   Experimental study on breakdown voltage between parallel plates in high-pressure helium [J].
Yue Shan ;
Liu Xing-Nan ;
Shi Zhen-Gang .
ACTA PHYSICA SINICA, 2015, 64 (10)
[30]   Vacuum Annealed β-Ga2O3 Recess Channel MOSFETs With 8.56 kV Breakdown Voltage [J].
Sharma, Shivam ;
Meng, Lingyu ;
Bhuiyan, A. F. M. Anhar Uddin ;
Feng, Zixuan ;
Eason, David ;
Zhao, Hongping ;
Singisetti, Uttam .
IEEE ELECTRON DEVICE LETTERS, 2022, 43 (12) :2029-2032