Fabrication of ascorbic sensor acid with Co3O4•Fe2O3 nanosphere materials by electrochemical technique

被引:20
作者
Alam, M. M. [1 ]
Balkhoyor, Hasan B. [2 ]
Asiri, Abdullah M. [2 ,3 ]
Karim, Mohammad Razaul [2 ,3 ]
Chani, Muhammad Tariq Saeed [2 ,3 ]
Rahman, Mohammed M. [2 ,3 ]
机构
[1] Shahjalal Univ Sci & Technol, Dept Chem Engn & Polymer Sci, Sylhet 3100, Bangladesh
[2] King Abdulaziz Univ, Fac Sci, Chem Dept, POB 80203, Jeddah 21589, Saudi Arabia
[3] King Abdulaziz Univ, Ctr Excellence Adv Mat Res CEAMR, POB 80203, Jeddah 21589, Saudi Arabia
关键词
Co3O4 center dot Fe2O3 nanospheres; Ascorbic acid sensor; Electrochemical method; Hydrothermal process; Sensitivity; Healthcare safety; GLASSY-CARBON ELECTRODE; REDUCED GRAPHENE OXIDE; VITAMIN-C; NANOPARTICLES; DOPAMINE; NANOSHEETS; HETEROSTRUCTURE; NANOCOMPOSITE; BIOSENSOR;
D O I
10.1016/j.surfin.2020.100607
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, the Co3O4 center dot Fe2O3 nanospheres (NSs) was prepared by hydrothermal process in high alkaline environment of pH 10.5. X-ray photoelectron spectroscopy (XPS), field Emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDS) and X-ray diffraction analysis were performed to characterize the prepared Co3O4 center dot Fe2O3 NSs. The Co3O4 center dot Fe2O3 NSs was subjected to deposit onto a glassy carbon electrode (GCE) of 0.0316 cm(2) surface area with nafion (5% suspension in ethanol) adhesive as thin film to obtain the desire ascorbic acid (AA) sensor. The calibration curve of AA sensor was plotted as current versus concentration of AA, which is a linear from 0.1 nM to 0.01 mM on calibration curve defined as linear dynamic range (LDR). The slope of LDR is used to calculate the sensitivity of sensor by considering the active surface area of electrode and is equal to 15.4367 mu A mu M-1 cm(-2). The limit of detection (LOD; 96.02 +/- 4.80 pM) and the limit of quantification (LOQ; 320.07 +/- 10.0 pM) of AA sensor are calculated. The reproducibility, response time and long-time stability of sensor are exhibited as outstanding. The electrochemical analyzing of real samples, the AA sensor is shown its reliability.
引用
收藏
页数:10
相关论文
共 68 条
  • [1] Abidov Amir, 2013, International Journal of Materials, Mechanics and Manufacturing, V1, P294, DOI 10.7763/IJMMM.2013.V1.63
  • [2] Efficient hydroquinone sensor development based on Co3O4 nanoparticle
    Abu-Zied, Bahaa M.
    Alam, M. M.
    Asiri, Abdullah M.
    Ahmed, Jahir
    Rahman, Mohammed M.
    [J]. MICROCHEMICAL JOURNAL, 2020, 157
  • [3] Capability of a carbon-polyvinylchloride composite electrode for the detection of dopamine, ascorbic acid and uric acid
    Aguilar, R
    Dávila, MM
    Elizalde, MP
    Mattusch, J
    Wennrich, R
    [J]. ELECTROCHIMICA ACTA, 2004, 49 (06) : 851 - 859
  • [4] Crystal structure of N′-[(E)-(2-hydroxynaphthalen-1-yl) methylidene] benzenesulfonohydrazide (HNMBSH) and its application as Pb2+ ion sensor by its fabrication onto glassy carbon electrode
    Ahmad, Ikram
    Arshad, Muhammad Nadeem
    Rahman, Mohammed M.
    Asiri, Abdullah M.
    Sheikh, Tahir Ali
    Aqlan, Faisal M.
    [J]. INORGANICA CHIMICA ACTA, 2017, 467 : 297 - 306
  • [5] Fabrication of hydrazine sensor based on silica-coated Fe2O3 magnetic nanoparticles prepared by a rapid microwave irradiation method
    Akhter, Hashi
    Murshed, Jannatul
    Rashed, Md. A.
    Oshima, Yoshifumi
    Nagao, Yuki
    Rahman, Mohammed M.
    Asiri, Abdullah M.
    Hasnat, M. A.
    Uddin, Md. Nizam
    Siddiquey, Iqbal Ahmed
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2017, 698 : 921 - 929
  • [6] Fabrication of phenylhydrazine sensor with V2O5 doped ZnO nanocomposites
    Alam, M. M.
    Asiri, Abdullah M.
    Rahman, Mohammed M.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2020, 243
  • [7] Detection of uric acid based on doped ZnO/ Ag2O/ Co3O4 nanoparticle loaded glassy carbon electrode
    Alam, M. M.
    Asiri, Abdullah M.
    Uddin, M. T.
    Islam, M. A.
    Awual, Md. Rabiul
    Rahman, Mohammed M.
    [J]. NEW JOURNAL OF CHEMISTRY, 2019, 43 (22) : 8651 - 8659
  • [8] In-situ Glycine Sensor Development Based ZnO/Al2O3/Cr2O3 Nanoparticles
    Alam, M. M.
    Asiri, Abdullah M.
    Uddin, M. T.
    Islam, M. A.
    Rahman, Mohammed M.
    [J]. CHEMISTRYSELECT, 2018, 3 (41): : 11460 - 11468
  • [9] In-situ synthesis of gold nanocrystals anchored graphene oxide and its application in biosensor and chemical sensor
    Alam, Mohammad K.
    Rahman, Md Mahbubur
    Rahman, Mohammed M.
    Kim, Dojin
    Asiri, Abdullah M.
    Khan, Feroz A.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 835 : 329 - 337
  • [10] Novel function of ascorbic acid as an angiostatic factor
    Hiromi Ashino
    Mariko Shimamura
    Hiroshi Nakajima
    Munehiko Dombou
    Satoshi Kawanaka
    Tsutomu Oikawa
    Takao Iwaguchi
    Seiichi Kawashima
    [J]. Angiogenesis, 2003, 6 (4) : 259 - 269