Differences of Retinal Blood Flow Between Arteries and Veins Determined by Laser Speckle Flowgraphy in Healthy Subjects

被引:26
作者
Iwase, Takeshi [1 ]
Ra, Eimei [1 ]
Yamamoto, Kentaro [1 ]
Kaneko, Hiroki [1 ]
Ito, Yasuki [1 ]
Terasaki, Hiroko [1 ]
机构
[1] Nagoya Univ, Dept Ophthalmol, Grad Sch Med, Nagoya, Aichi 4668560, Japan
基金
日本学术振兴会;
关键词
OPTIC-NERVE HEAD; NORMAL-TENSION GLAUCOMA; 2-DIMENSIONAL MEASUREMENT; CIRCULATION; PRESSURE; VELOCITY; MICROCIRCULATION; ERYTHROCYTES; MICROVESSELS; HYPERTENSION;
D O I
10.1097/MD.0000000000001256
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To characterize the total retinal blood flow determined by laser speckle flowgraphy (LSFG) of healthy subjects.This prospective cross-sectional study was conducted at the Nagoya University Hospital. One hundred fifteen right eyes of 115 healthy subjects (mean age: 39.416.1 years) were studied. The total blood flow in the retinal arteries and veins around the optic nerve head was measured separately using the total retinal flow index (TRFI), which represents blood flow volume. The lumen diameters of the retinal vessels determined by LSFG and by adaptive optics (AO) camera were compared. The images obtained by LSFG and AO camera were merged, and the distribution of the mean blur rates (MBRs), which represent the velocities of the erythrocytes, was evaluated on the images.The mean TRFI in veins (1812 +/- 445, arbitral units) was significantly higher than that in arteries (1455 +/- 348, arbitral units; P<0.001). Linear regression analysis showed a significant correlation between the TRFI in the arteries and veins (P<0.001). Linear regression analysis also showed a highly significant correlation between the diameters of arteries and veins determined by LSFG and by the AO camera (arteries, r=0.94, P<0.001; veins, r=0.92, P<0.001). The ratios of the lumen diameters determined by LSFG to that by AO camera was significant lower in arteries (0.068 +/- 0.005, arbitral units) than in veins (0.074 +/- 0.007, arbitral units) (P<0.001). The MBRs of veins were homogeneous throughout the width of the lumen; however, the MBRs in the arteries were higher at the center and lower close to the walls of the lumen.The higher TRFIs in the veins than in the arteries indicate that there is a smaller volume of retinal blood flow in arteries than veins. However, the possibility remains that LSFG has inherent problem that the arterial lumen diameter determined by LSFG is smaller than actual one because of the characteristics of arteries. This would result in a smaller volume of retinal blood flow in the arteries than veins in LSFG.
引用
收藏
页数:8
相关论文
共 38 条
[1]   Effect of coffee consumption on Intraocular pressure [J].
Avisar, R ;
Avisar, E ;
Weinberger, D .
ANNALS OF PHARMACOTHERAPY, 2002, 36 (06) :992-995
[2]   Imaging of Vascular Wall Fine Structure in the Human Retina Using Adaptive Optics Scanning Laser Ophthalmoscopy [J].
Chui, Toco Y. P. ;
Gast, Thomas J. ;
Burns, Stephen A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) :7115-7124
[3]   Early Retinal Arteriolar Changes and Peripheral Neuropathy in Diabetes [J].
Ding, Jie ;
Cheung, Carol Y. ;
Ikram, M. Kamran ;
Zheng, Ying-Feng ;
Cheng, Ching-Yu ;
Lamoureux, Ecosse L. ;
Tai, E. Shyong ;
Subramaniam, Tavintharan ;
Wong, Tien Yin .
DIABETES CARE, 2012, 35 (05) :1098-1104
[4]   Subfoveal Choroidal Blood Flow and Central Retinal Function in Retinitis Pigmentosa [J].
Falsini, Benedetto ;
Anselmi, Gian Mario ;
Marangoni, Dario ;
D'Esposito, Fabiana ;
Fadda, Antonello ;
Di Renzo, Antonio ;
Campos, Emilio C. ;
Riva, Charles E. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (02) :1064-1069
[5]  
FEKE GT, 1989, INVEST OPHTH VIS SCI, V30, P58
[6]   Pulsatile ocular blood flow investigation in asymmetric normal tension glaucoma and normal subjects [J].
Fontana, L ;
Poinoosawmy, D ;
Bunce, CV ;
O'Brien, C ;
Hitchings, RA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (07) :731-736
[7]   EVALUATION OF BLOOD-FLOW BY LASER SPECKLE IMAGE SENSING .1. [J].
FUJII, H ;
NOHIRA, K ;
YAMAMOTO, Y ;
IKAWA, H ;
OHURA, T .
APPLIED OPTICS, 1987, 26 (24) :5321-5325
[8]   VISUALIZATION OF RETINAL BLOOD-FLOW BY LASER SPECKLE FLOWGRAPHY [J].
FUJII, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (03) :302-304
[9]  
Fujii H, 1996, ATARASHII GANKA, V13, P957
[10]   Retinal Blood Flow in Healthy Young Subjects [J].
Garhofer, Gerhard ;
Werkmeister, Rene ;
Dragostinoff, Nikolaus ;
Schmetterer, Leopold .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (02) :698-703