RECONSTRUCTION TECHNIQUE OF FLUORESCENT X-RAY COMPUTED TOMOGRAPHY USING SHEET BEAM

被引:0
|
作者
Nakamura, Shunsuke [1 ]
Huo, Qingkai [1 ]
Yuasa, Tetsuya [1 ]
机构
[1] Yamagata Univ, 4-3-16 Jonan, Yonezawa, Yamagata 9928510, Japan
来源
2014 PROCEEDINGS OF THE 22ND EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO) | 2014年
关键词
Fluorescent x-ray; computed tomography; quantitativeness; reconstruction; attenuated Radon transform; SYNCHROTRON-RADIATION; PHASE-CONTRAST; CT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We clarify the measurement process of fluorescent x-ray computed tomography (FXCT) using sheet-beam as incident beam, and show that the process leads to the attenuated Radon transform. In order to improve quantitativeness, we apply Natterer's scheme to the FXCT reconstruction. We show its efficacy by computer simulation.
引用
收藏
页码:1975 / 1979
页数:5
相关论文
共 50 条
  • [21] A new scanning technique for X-ray computed tomography
    Nukaga, Jun
    Kitazawa, So
    Kamimura, Hiroshi
    NDT & E INTERNATIONAL, 2008, 41 (07) : 564 - 569
  • [22] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [23] Sparsity Prior Computed Tomography Reconstruction Using a Nonstandard Simultaneous X-ray Acquisition Model
    Saha, Sajib Kumar
    Tahtali, Murat
    Lambert, Andrew
    Pickering, Mark
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (03) : 251 - +
  • [24] Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation
    Hayakawa, Y.
    Hayakawa, K.
    Inagaki, M.
    Kaneda, T.
    Nakao, K.
    Nogami, K.
    Sakae, T.
    Sakai, T.
    Sato, I.
    Takahashi, Y.
    Tanaka, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 230 - 236
  • [25] Helical differential X-ray phase-contrast computed tomography
    Fu, Jian
    Willner, Marian
    Chen, Liyuan
    Tan, Renbo
    Achterhold, Klaus
    Bech, Martin
    Herzen, Julia
    Kunka, Danays
    Mohr, Juergen
    Pfeiffer, Franz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 374 - 379
  • [26] Combined X-ray fluorescence and absorption computed tomography using a synchrotron beam
    Hall, C.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [27] Metal Artifact Reduction Based on Beam Hardening Correction and Statistical Iterative Reconstruction for X-ray Computed Tomography
    Zhang, Yanbo
    Mou, Xuanqin
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [28] Imaging of patients having metal implant using X-ray Computed Tomography
    Liu, Julian J.
    Lutkin, John E.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2009, 17 (04) : 355 - 365
  • [29] Evaluation of Computed Tomography X-Ray Beam Dose Profiles
    Civa, Lejla M.
    Beganovic, Adnan
    Redzic, Mahira
    Lasic, Ivan
    Gazdic-Santic, Maja
    Skopljak-Beganovic, Amra
    Jasic, Rahima
    Vegar-Zubovic, Sandra
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, CMBEBIH 2019, 2020, 73 : 137 - 141
  • [30] Beam hardening correction for X-ray computed tomography of heterogeneous natural materials
    Ketcham, Richard A.
    Hanna, Romy D.
    COMPUTERS & GEOSCIENCES, 2014, 67 : 49 - 61