Selenium species in aqueous extracts of alfalfa sprouts by two-dimensional liquid chromatography coupled to inductively coupled plasma mass spectrometry and electrospray mass Spectrometry detection

被引:24
|
作者
Gergely, Valeria
Montes-Bayon, Maria
Fodor, Peter
Sanz-Medel, Alfredo
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Corvinus Univ Budapest, Fac Food Sci, Dept Appl Chem, H-1118 Budapest, Hungary
关键词
selenium; alfalfa sprouts; HPLC-ICP-MS; ESI-Q-TOF;
D O I
10.1021/jf060320n
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The complementary use of two different liquid chromatographic mechanisms coupled to inductively coupled plasma mass spectrometry (ICP-MS) for selenium ( Se) specific detection has permitted the screening of the most abundant Se-containing fractions in selenized alfalfa sprouts ( Medicago sativa). Aqueous extracts of the sprouts were fractionated first by size exclusion chromatography ( SEC) using a Superdex Peptide column and a mobile phase containing an ammonium acetate buffer (pH 7). Further purification of the individual SEC Se-containing fractions was carried out using two different chromatographic systems: a Shodex Ashaipack column, with a mixed mechanism of size exclusion and ion exchange, and a conventional reversed phase C-8 using ion-pairing reagents. In both cases, the columns were coupled to an inductively coupled plasma mass spectrometer equipped with an octapole reaction system for Se specific detection. This system allowed the on-line monitoring of the most abundant Se isotopes (Se-78, Se-80) by reducing the possible polytomic interferences affecting these ions by adding hydrogen (2 mL min(-1)) to the octapole reaction cell. The results obtained by both separation mechanisms were highly comparable, revealing the presence of Se-methionine and Se-methyl selenocysteine. Both compounds were then confirmed by analyzing the corresponding fractions by electrospray quadrupole-time-of-flight (ESI-Q-TOF) mass spectrometry. Finally, an additional Se-containing species showing Se isotope distribution was detected at a molecular ion m/z 239 in the ESI-Q-TOF. The collision-induced dissociation of the m/z 239 and 237 ions ( corresponding to Se-80 and Se-78 isotopes, respectively) revealed the possible presence as well of a derivative of the Se-2-propenyl selenocysteine.
引用
收藏
页码:4524 / 4530
页数:7
相关论文
共 50 条
  • [41] Sequential hydride generation/pneumatic nebulisation inductively coupled plasma mass spectrometry for the fractionation of arsenic and selenium species
    Anderson, SL
    Pergantis, SA
    TALANTA, 2003, 60 (04) : 821 - 830
  • [42] Determination of selenium compounds in food supplements using reversed-phase liquid chromatography-inductively coupled plasma mass spectrometry
    Hsieh, Yu-Jhe
    Jiang, Shiuh-Jen
    MICROCHEMICAL JOURNAL, 2013, 110 : 1 - 7
  • [43] Capabilities of mixed-mode liquid chromatography coupled to inductively coupled plasma mass spectrometry for the simultaneous speciation analysis of inorganic and organically-bound selenium
    Peachey, Emma
    Cook, Ken
    Castles, Adrian
    Hopley, Christopher
    Goenaga-Infante, Heidi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (42) : 7001 - 7006
  • [44] Speciation of Selenium in Selenium-Enriched Foods by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Tandem Mass Spectrometry
    Luo, Yue
    Chen, Gang
    Deng, Xiuqing
    Cai, Hanqing
    Fu, Xueheng
    Xu, Fujian
    Xiao, Xiaonian
    Huo, Yumeng
    Luo, Jin
    SEPARATIONS, 2022, 9 (09)
  • [45] The Application of Inductively Coupled Plasma Mass Spectrometry in Cancer Research
    Zang, Zhikun
    Liu, Xiaolan
    Wang, Meng
    Wang, Zhibin
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2025,
  • [46] Studies of metal species in water extracts from metallophytes employing solid phase extraction and size exclusion chromatography coupled to inductively coupled plasma mass spectrometry
    Nkoane, Bonang B. M.
    Lund, Walter
    Wibetoe, Grethe
    Torto, Nelson
    GEOCHEMISTRY-EXPLORATION ENVIRONMENT ANALYSIS, 2011, 11 (03) : 225 - 231
  • [47] Characterization of phosphonate-based antiscalants used in drinking water treatment plants by anion-exchange chromatography coupled to electrospray ionization time-of-flight mass spectrometry and inductively coupled plasma mass spectrometry
    Armbruster, Dominic
    Mueller, Uwe
    Happel, Oliver
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 : 189 - 204
  • [48] Analysis of Mass Bias in Measurement of Selenium Isotope with Multi-collectors Inductively Coupled Plasma Mass Spectrometry
    Ren Tong-Xiang
    Lu Hai
    Wang Jun
    He Xin-Yu
    Zhou Tao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (11) : 1620 - 1624
  • [49] Determination of arsenic species in mainstream cigarette smoke based on inductively coupled plasma mass spectrometry
    Huang, Jia-Ruo
    Li, Peng
    Wen, Jian-Hui
    Hu, Xin
    Chen, Yi-Jun
    Yin, Dong-Hong
    Lian, Hong-Zhen
    SPECTROSCOPY LETTERS, 2018, 51 (06) : 252 - 256
  • [50] Determination of selenomethionine, selenocysteine, and inorganic selenium in eggs by HPLC–inductively coupled plasma mass spectrometry
    Elżbieta Lipiec
    Grzegorz Siara
    Katarzyna Bierla
    Laurent Ouerdane
    Joanna Szpunar
    Analytical and Bioanalytical Chemistry, 2010, 397 : 731 - 741