Standardization and quantification of radionuclide solid gastric-emptying studies

被引:0
作者
Ziessman, HA
Fahey, FH
Atkins, FB
Tall, J
机构
[1] Johns Hopkins Med Inst, Dept Radiol, Div Nucl Med, Baltimore, MD USA
[2] Childrens Hosp, Boston, MA 02115 USA
[3] Washington Hosp Ctr, Washington, DC 20010 USA
关键词
gastric emptying; Tc-99m-sulfur colloid; stomach; gastroparesis;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purposes of this investigation were to standardize and validate a simple quantitative method for performing radionuclide solid gastric emptying that can be used for any dual-head gamma-camera and to establish reference values. Methods: After eating a solid meal (egg sandwich) labeled with a radionuclide, 20 healthy volunteers (9 male, 11 female) underwent a 90-min gastric-emptying study performed with a triple-head gamma-camera. Two sets of 3 simultaneous projections were acquired sequentially for 30 s each: anterior, right posterior oblique (RPO), left posterior oblique (LPO), posterior, left anterior oblique (LAO), and right anterior oblique (RAO), and this sequence was repeated continuously for 90 min. Time-activity curves were generated using a gastric region of interest for each of the views as well as the conjugate-view geometric mean (GM) data for the anterior/posterior, LAO/RPO, and RAO/LPO combinations. Quantitative parameters were determined: percentage gastric emptying (%GE) at 90 min, half-time (min) based on an exponential fit, and clearance rate (%/min) based on a linear fit. Reference values were determined on the basis of a 95% confidence interval of the t distribution. The results were statistically analyzed and compared. Results: The %GE reference values were greater for the anterior/posterior GM ( greater than or equal to 33%) than for the LAO ( greater than or equal to 31%) and anterior ( greater than or equal to 30%) GMs. The 3% GE GM methods, the 3 exponential-fit GM methods, and the 3 linear-fit GM methods had high correlation coefficients (r greater than or equal to 0.874), and with only a single exception, there was no statistical difference among them. The LAO method and LAO/RPO GM mean method correlated strongly (r = 0.900) and had similar mean values (52% vs. 51%) and reference values (29% vs. 30%). All 3 methods of GM quantification also correlated strongly, and there was no significant difference among them. Conclusion: We have described and validated a simple method for radionuclide solid gastric emptying that can be used with a dual-head gamma-camera. We recommend the anterior/posterior GM method and have established reference values ( 33%).
引用
收藏
页码:760 / 764
页数:5
相关论文
共 27 条
[1]   IMPAIRED GASTRIC-EMPTYING IN DIABETIC-PATIENTS WITH CARDIAC AUTONOMIC NEUROPATHY [J].
BUYSSCHAERT, M ;
MOULART, M ;
URBAIN, JL ;
PAUWELS, S ;
DEROY, L ;
KETELSLEGERS, JM ;
LAMBERT, AE .
DIABETES CARE, 1987, 10 (04) :448-452
[2]  
CAMERILLI M, 1985, AM J PHYSIOL, V249, pG580
[3]  
CHRISTIAN PE, 1991, J NUCL MED, V32, P1349
[4]  
CHRISTIAN PE, 1980, J NUCL MED, V21, P883
[5]   CORRECTION FOR TISSUE ATTENUATION IN RADIONUCLIDE GASTRIC-EMPTYING STUDIES - A COMPARISON OF A LATERAL IMAGE METHOD AND A GEOMETRIC MEAN METHOD [J].
COLLINS, PJ ;
HOROWITZ, M ;
SHEARMAN, DJC ;
CHATTERTON, BE .
BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (680) :689-695
[6]  
FAHEY FH, 1989, J NUCL MED, V30, P233
[7]  
FORD PV, 1992, J NUCL MED, V33, P127
[8]   Extending gastric emptying scintigraphy from two to four hours detects more patients with gastroparesis [J].
Guo, JP ;
Maurer, AH ;
Fisher, RS ;
Parkman, HP .
DIGESTIVE DISEASES AND SCIENCES, 2001, 46 (01) :24-29
[9]   ACUTE AND CHRONIC EFFECTS OF DOMPERIDONE ON GASTRIC-EMPTYING IN DIABETIC AUTONOMIC NEUROPATHY [J].
HOROWITZ, M ;
HARDING, PE ;
CHATTERTON, BE ;
COLLINS, PJ ;
SHEARMAN, DJC .
DIGESTIVE DISEASES AND SCIENCES, 1985, 30 (01) :1-9
[10]  
HOROWITZ M, 1983, INT J OBESITY, V7, P415