Automated Artifact Removal From the Electroencephalogram: A Comparative Study

被引:36
|
作者
Daly, Ian [1 ]
Nicolaou, Nicoletta [2 ]
Nasuto, Slawomir Jaroslaw [3 ]
Warwick, Kevin [3 ]
机构
[1] Graz Univ Technol, Inst Knowledge Discovery, Lab Brain Comp Interfaces, A-8010 Graz, Austria
[2] Univ Cyprus, Holist Elect Res Lab, Dept Elect & Comp Engn, Nicosia, Cyprus
[3] Univ Reading, Dept Cybernet, Brain Embodiment Lab, Reading RG6 2AH, Berks, England
基金
英国工程与自然科学研究理事会;
关键词
Automated artifact removal; Independent component analysis (ICA); Temporal de-correlation source separation (TDSEP); Blind source separation (BSS); Multivariate singular spectrum analysis (MSSA); Wavelets; EEG; EMG;
D O I
10.1177/1550059413476485
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Contamination of the electroencephalogram (EEG) by artifacts greatly reduces the quality of the recorded signals. There is a need for automated artifact removal methods. However, such methods are rarely evaluated against one another via rigorous criteria, with results often presented based upon visual inspection alone. This work presents a comparative study of automatic methods for removing blink, electrocardiographic, and electromyographic artifacts from the EEG. Three methods are considered; wavelet, blind source separation (BSS), and multivariate singular spectrum analysis (MSSA)-based correction. These are applied to data sets containing mixtures of artifacts. Metrics are devised to measure the performance of each method. The BSS method is seen to be the best approach for artifacts of high signal to noise ratio (SNR). By contrast, MSSA performs well at low SNRs but at the expense of a large number of false positive corrections.
引用
收藏
页码:291 / 306
页数:16
相关论文
共 50 条
  • [31] Online removal of ocular artefacts from the electroencephalogram
    Jervis, BW
    Garcia, MIB
    Thomlinson, M
    Lopez, JML
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2004, 151 (01) : 47 - 51
  • [32] A comparative study of accuracy in major adaptive filters for motion artifact removal in sleep apnea tests
    Chen, Yongrui
    Zheng, Yurui
    Johnson, Sam
    Wiffen, Richard
    Yang, Bin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (03) : 829 - 842
  • [33] A comparative study of accuracy in major adaptive filters for motion artifact removal in sleep apnea tests
    Yongrui Chen
    Yurui Zheng
    Sam Johnson
    Richard Wiffen
    Bin Yang
    Medical & Biological Engineering & Computing, 2024, 62 : 829 - 842
  • [34] Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
    Bae, Jihye
    Clay, Jordan L.
    Thapa, Bhoj Raj
    Powell, David
    Turpin, Heidi
    Partovi, Saghi Tasori
    Ward-Mitchell, Rachel
    Krishnan, Balu
    Koupparis, Andreas
    Owen, Meriem Bensalem
    Raslau, Flavius D.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (196):
  • [35] Seizure or Shiver? Artifact in the Electroconvulsive Therapy Electroencephalogram
    Schwartz, Elizabeth K. C.
    Kellner, Charles H.
    JOURNAL OF ECT, 2015, 31 (02) : 79 - 79
  • [36] Unsupervised Eye Blink Artifact Identification in Electroencephalogram
    Egambaram, Ashvaany
    Badruddin, Nasreen
    Asirvadam, Vijanth S.
    Fauvet, Eric
    Stolz, Christophe
    Begum, Tahamina
    PROCEEDINGS OF TENCON 2018 - 2018 IEEE REGION 10 CONFERENCE, 2018, : 2148 - 2152
  • [37] Localized component filtering for electroencephalogram artifact rejection
    Delpozo-Banos, Marcos
    Weidemann, Christoph T.
    PSYCHOPHYSIOLOGY, 2017, 54 (04) : 608 - 619
  • [38] Vagal Nerve Stimulator Induced Artifact on Electroencephalogram
    Pervin, Saniya
    Youssefi, Julie
    Mathias, Sally
    ANNALS OF NEUROLOGY, 2023, 94 : S134 - S134
  • [39] Automatic artifact removal from GFR measurements
    Shmarlouski, A. (Anatoli.Shmarlouski@medma.uni-heidelberg.de), 1600, Elsevier Ltd (14):
  • [40] Removal of ocular artifact from the EEG: a review
    Croft, RJ
    Barry, RJ