Nonintrusive Load Monitoring of Variable Speed Drive Cooling Systems

被引:5
作者
Lindahl, Peter A. [1 ]
Ali, Muhammad Tauha [2 ]
Armstrong, Peter [2 ]
Aboulian, Andre [3 ]
Donnal, John [4 ]
Norford, Les [5 ]
Leeb, Steven B. [3 ]
机构
[1] Exponent Inc, Natick, MA 01760 USA
[2] Khalifa Univ Sci & Technol, Dept Mech Engn, Abu Dhabi, U Arab Emirates
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] US Naval Acad, Weapons & Syst Engn Dept, Annapolis, MD 21402 USA
[5] MIT, Dept Architecture, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
Cooling; Buildings; Monitoring; Refrigerants; Harmonic analysis; Heating systems; Power system harmonics; Air conditioning; condition monitoring; cooling; HVAC; nonintrusive load monitoring; smart meters; variable speed drives; ENERGY-CONSUMPTION; DISAGGREGATION; MODEL; TEMPERATURE;
D O I
10.1109/ACCESS.2020.3039408
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To improve the energy efficiencies of building cooling systems, manufacturers are increasingly utilizing variable speed drive (VSD) motors in system components, e.g. compressors and condensers. While these technologies can provide significant energy savings, these benefits are only realized if these components operate as intended and under proper control. Undetected faults can foil efficiency gains. As such, it's imperative to monitor cooling system performance to both identify faulty conditions and to properly inform building or multi-building models used for predictive control and energy management. This paper presents nonintrusive load monitoring (NILM) based "mapping" techniques for tracking the performance of a building's central air conditioning from smart electrical meter or energy monitor data. Using a multivariate linear model, a first mapping disaggregates the air conditioner's power draw from that of the total building by exploiting the correlations between the building's line-current harmonics and the power consumption of the air conditioner's VSD motors. A second mapping then estimates the air conditioner's heat rejection performance using as inputs the estimated power draw of the first mapping, the building's zonal temperature, and the outside environmental temperature. The usefulness of these mapping techniques are demonstrated using data collected from a research facility building on the Masdar City Campus of Khalifa University. The mapping techniques combine to provide accurate estimates of the building's air conditioning performance when operating under normal conditions. These estimates could thus be used as feedback in building energy management controllers and can provide a performance baseline for detection of air conditioner underperformance.
引用
收藏
页码:211451 / 211463
页数:13
相关论文
共 50 条
  • [21] Nonintrusive Appliance Load Monitoring Based on Integer Programming
    Inagaki, Shinkichi
    Egami, Tsukasa
    Suzuki, Tatsuya
    Nakamura, Hisahide
    Ito, Koichi
    ELECTRICAL ENGINEERING IN JAPAN, 2011, 174 (02) : 18 - 25
  • [22] Nonintrusive Load Monitoring Using an LSTM With Feedback Structure
    Hwang, Hyeontaek
    Kang, Sanggil
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [23] Testing and Performance Evaluation of Nonintrusive Load Monitoring Algorithms
    Luan W.
    Wei Z.
    Liu B.
    Liu Z.
    Yu Y.
    Dianwang Jishu/Power System Technology, 2022, 46 (11): : 4568 - 4579
  • [24] A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation
    Mayhorn, Ebony
    Butzbaugh, Joshua
    Meier, Alan
    SENSORS, 2023, 23 (19)
  • [25] Nonintrusive Appliance Load Monitoring Based on Integer Programming
    Suzuki, Kosuke
    Inagaki, Shinkichi
    Suzuki, Tatsuya
    Nakamura, Hisahide
    Ito, Koichi
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 2626 - +
  • [26] Enhancing Nonintrusive Load Monitoring With Targeted Adaptive Networks
    Zhao, Maojiang
    Chen, Song
    Xiong, Zuqiang
    Bai, Zhemin
    Yang, Yu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [27] Nonintrusive appliance load monitoring based on integer programming
    Inagaki, Shinkichi
    Egami, Tsukasa
    Suzuki, Tatsuya
    Nakamura, Hisahide
    Ito, Koichi
    IEEJ Transactions on Power and Energy, 2008, 128 (11) : 1386 - 1392+12
  • [28] Virtual Metering: An Efficient Water Disaggregation Algorithm via Nonintrusive Load Monitoring
    Wang, Bingsheng
    Chen, Zhiqian
    Boedihardjo, Arnold P.
    Lu, Chang-Tien
    ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2018, 9 (04)
  • [29] GI-Transformer: A Transformer Model With Feature Interaction for Nonintrusive Load Monitoring
    Liu, Xiaoyang
    Jiang, Tao
    Luo, Haiyue
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [30] DistribuNet: A Robust Neural Framework for Mitigating Distributional Shifts in Nonintrusive Load Monitoring
    Xu, Yang
    Xu, Qingshan
    Xia, Yuanxing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74