Add-On Sulcus-Based Versus Primary In-the-Bag Multifocal Intraocular Lens: Intraindividual Study

被引:7
作者
Munoz, Gonzalo [1 ,2 ,3 ,4 ]
Albarran-Diego, Cesar [1 ,2 ,3 ,4 ]
Belda, Lurdes [1 ,2 ,3 ]
Rohrweck, Stephanie [4 ]
机构
[1] Ctr Oftalmol Marques de Sotelo, Dept Refract Surg, Valencia 46002, Spain
[2] Hosp NISA Valencia Mar, Valencia 46002, Spain
[3] Univ Valencia, Dept Opt, Optometry Res Grp, Valencia, Spain
[4] Clin Baviera Castellon, Castellon de La Plana, Spain
关键词
PSEUDOPHAKIC REFRACTIVE ERRORS; PIGGYBACK IMPLANTATION; HIGH ASTIGMATISM; CASE SERIES; QUALITY; RESTOR;
D O I
10.3928/1081597X-20140422-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the clinical outcomes of add-on sulcus-based multifocal and standard in-the-bag multifocal intraocular lens (IOL) implantation. METHODS: Twenty-one patients with unilateral monofocal pseudophakia underwent add-on sulcus-based Acri. LISA 536D multifocal IOL (Carl Zeiss Meditec, Jena, Germany) implantation (add-on multifocal IOL group) and contralateral phacoemulsification with in-the-bag Acri. LISA 376D multifocal IOL (Carl Zeiss Meditec) implantation (primary multifocal IOL group). Uncorrected distance visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected near visual acuity, photopic (90 cd/m(2)) distance, near contrast sensitivity, mesopic (5 cd/m(2)) distance contrast sensitivity with and without glare, wavefront aberrations, and complications were measured 6 months postoperatively. RESULTS: Primary in-the-bag multifocal IOLs provided slightly but significantly better uncorrected distance visual acuity (0.08 +/- 0.10 vs 0.17 +/- 0.15 logMAR, P = .028), uncorrected near visual acuity (0.09 +/- 0.17 vs 0.18 +/- 0.11 logMAR, P = .005), and corrected distance visual acuity (0.01 +/- 0.04 vs 0.04 +/- 0.05 logMAR, P = .038). There were no significant differences in distance-corrected near visual acuity, photopic or mesopic contrast sensitivity under different conditions, and wavefront aberrations. Complications included pigment dispersion in one eye (4.8%) and pupillary capture in 2 eyes (9.5%) of the add-on multifocal IOL group. CONCLUSIONS: The secondary add-on sulcus-based multifocal IOL provided useful pseudoaccommodation with vision quality similar to the primary in-the-bag multifocal IOL. The technique should be considered in patients diagnosed as having unilateral or bilateral monofocal pseudophakia seeking near spectacle independence.
引用
收藏
页码:320 / +
页数:9
相关论文
empty
未找到相关数据