High-voltage monitoring with a solenoid retarding spectrometer at the KATRIN experiment

被引:16
|
作者
Erhard, M. [1 ]
Bauer, S. [2 ]
Beglarian, A. [1 ]
Bergmann, T. [1 ]
Bonn, J. [3 ]
Drexlin, G. [1 ]
Goullon, J. [1 ]
Groh, S. [1 ]
Glueck, F. [1 ,4 ]
Kleesiek, M. [1 ]
Haussmann, N. [1 ]
Hoehn, T. [1 ]
Johnston, K. [5 ]
Kraus, M. [1 ]
Reich, J. [1 ]
Rest, O. [2 ]
Schloesser, K. [1 ]
Schupp, M. [1 ]
Slezak, M. [6 ,7 ]
Thuemmler, T. [1 ]
Venos, D. [7 ]
Weinheimer, C. [2 ]
Wuestling, S. [1 ]
Zboril, M. [2 ]
机构
[1] Karlsruhe Inst Technol, KCETA, D-76131 Karlsruhe, Germany
[2] Univ Munster, Inst Nucl Phys, D-48149 Munster, Germany
[3] Johannes Gutenberg Univ Mainz, Inst Phys, D-55099 Mainz, Germany
[4] Wigner Res Inst Phys, H-1525 Budapest, Hungary
[5] CERN, Dept Phys, CH-1211 Geneva, Switzerland
[6] Charles Univ Prague, Fac Math & Phys, CZ-12116 Prague, Czech Republic
[7] Acad Sci Czech Republ, Inst Nucl Phys, CZ-25068 Rez, Czech Republic
来源
关键词
Real-time monitoring; Spectrometers; Control systems; NEUTRINO; RESOLUTION; SPECTRA;
D O I
10.1088/1748-0221/9/06/P06022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The KATRIN experiment will measure the absolute mass scale of neutrinos with a sensitivity of m(v) = 200 meV/c(2) by means of an electrostatic spectrometer set close to the tritium beta-decay endpoint at 18.6 keV. Fluctuations of the energy scale must be under control within +/- 60 mV (+/- 3 ppm). Since a precise voltage measurement in the range of tens of kV is on the edge of current technology, a nuclear standard will be deployed additionally. Parallel to the main spectrometer the same retarding potential will be applied to the monitor spectrometer to measure 17.8-keV K-conversion electrons of Kr-83m. This article describes the setup of the monitor spectrometer and presents its first measurement results.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Precision High Voltage Monitoring for the KATRIN Experiment
    Thuemmler, Thomas
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 293 - 295
  • [2] The Katrin experiment and the pre-spectrometer at reduced retarding potential
    Prall, M.
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 2011, 66 (02) : 418 - 423
  • [3] Wideband precision stabilization of the-18.6 kV retarding voltage for the KATRIN spectrometer
    Rodenbeck, C.
    Wuestling, S.
    Enomoto, S.
    Hartmann, J.
    Rest, O.
    Thuemmler, T.
    Weinheimer, C.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (06)
  • [4] Precision high voltage divider for the KATRIN experiment
    Thuemmler, Th
    Marx, R.
    Weinheimer, Ch
    NEW JOURNAL OF PHYSICS, 2009, 11
  • [5] A SOLENOID RETARDING SPECTROMETER WITH HIGH-RESOLUTION AND TRANSMISSION FOR KEV ELECTRONS
    PICARD, A
    BACKE, H
    BARTH, H
    BONN, J
    DEGEN, B
    EDLING, T
    HAID, R
    HERMANNI, A
    LEIDERER, P
    LOEKEN, T
    MOLZ, A
    MOORE, RB
    OSIPOWICZ, A
    OTTEN, EW
    PRZYREMBEL, M
    SCHRADER, M
    STEININGER, M
    WEINHEIMER, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 63 (03): : 345 - 358
  • [6] HIGH-VOLTAGE PULSED GENERATOR WITH PROTECTING SOLENOID
    VOLODIN, VD
    GLAGOLEVA, NS
    KAMINSKII, NI
    MATYUSHIN, AT
    MATYUSHIN, VT
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (05) : 1289 - 1291
  • [7] Electromagnetic design of the spectrometer section of the KATRIN experiment
    Mertens, S.
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 2010, 64 (02) : 294 - 296
  • [8] High speed solenoid actuator for high-voltage circuit breaker
    Yun, So-Nam
    Jeong, Hwang-Hoon
    Hwang, Soon-Chan
    Kim, Hyo-Bong
    Park, In-Seop
    2011 11TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2011, : 1006 - 1010
  • [9] Energy calibration and monitoring of the KATRIN experiment
    Thuemmler, T.
    Beck, M.
    Bonn, J.
    Hillen, B.
    Ortjohann, H. W.
    Ostrick, B.
    Otten, E. W.
    Prall, M.
    Titov, N.
    Weinheimer, C.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2012, 221 : 405 - 405
  • [10] MEASUREMENTS OF HIGH-VOLTAGE FLUCTUATIONS WITH THE MOLLENSTEDT ELECTRON SPECTROMETER
    WEIMER, E
    GAUKLER, KH
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (07): : 629 - 631