Trajectories of Perceived Emotional and Physical Distress in Patients with an Implantable Cardioverter Defibrillator

被引:15
|
作者
van den Broek, Krista C. [1 ]
Kupper, Nina [1 ]
van der Voort, Pepijn H. [2 ]
Alings, Marco [3 ]
Denollet, Johan [1 ]
Nyklicek, Ivan [1 ]
机构
[1] Tilburg Univ, CoRPS Ctr Res Psychol Somat Dis, Dept Med Psychol, NL-5000 LE Tilburg, Netherlands
[2] Catharina Hosp, Dept Cardiol, Eindhoven, Netherlands
[3] Amphia Hosp, Dept Cardiol, Breda, Netherlands
关键词
Implantable cardioverter defibrillator; Anxiety; Depression; Health Status; Personality; QUALITY-OF-LIFE; RANDOMIZED CONTROLLED-TRIAL; CORONARY-HEART-DISEASE; D PERSONALITY; SECONDARY PREVENTION; ANXIETY SENSITIVITY; NEGATIVE AFFECTIVITY; CENTERED OUTCOMES; HEALTH COMPLAINTS; SOCIAL INHIBITION;
D O I
10.1007/s12529-012-9275-9
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
Background Little is known about the course of emotional and physical distress in patients with an implantable cardioverter defibrillator (ICD). Purpose We examined (1) trajectories of emotional and physical distress in the first 18 months postimplantation and (2) predictors of these trajectories, including demographical, clinical, and personality factors. Methods Dutch patients with an ICD (N = 645) completed measures on anxiety, depression, somatic symptoms, and perceived disability at the time of implantation, and 2, 12, and 18 months postimplantation. Measures on Type D personality (tendency to inhibit the expression of negative emotions) and anxiety sensitivity (tendency to fear anxiety-related sensations) were also completed at baseline. Results Latent class analysis (LatentGOLD) identified six to seven distinct trajectories, varying largely in overall levels of distress, and remaining relatively stable after a small initial decline. Multinomial regression showed that Type D personality and anxiety sensitivity were the most prominent predictors, particularly of trajectories that reflected higher distress levels. Cardiac resynchronization therapy and coronary artery disease also increased the risk for distress, whereas ICD indication and shocks did not. Conclusions The course of emotional and physical distress may be relatively stable after ICD implantation. In clinical practice, identification of patients with high risk of higher levels of emotional and physical distress may be warranted; as such, patients with high levels of anxiety sensitivity or a Type D personality should be identified and offered behavioral support.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [41] A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator: A preliminary study
    Brouwers, Corline
    Caliskan, Kadir
    de Jonge, Nicolaas
    Theuns, Dominic A. J. M.
    Constantinescu, A.
    Young, Quincy-Robyn
    Cannon, Colleen
    Denollet, Johan
    Pedersen, Susanne S.
    HEART & LUNG, 2014, 44 (01): : 27 - 32
  • [42] Web-Based Distress Management for Implantable Cardioverter Defibrillator Patients: A Randomized Controlled Trial
    Habibovic, Mirela
    Denollet, Johan
    Cuijpers, Pim
    van der Voort, Pepijn H.
    Herrman, Jean-Paul
    Bouwels, Leon
    Valk, Suzanne D. A.
    Alings, Marco
    Theuns, Dominic A. M. J.
    Pedersen, Susanne S.
    HEALTH PSYCHOLOGY, 2017, 36 (04) : 392 - 401
  • [43] INFECTIONS IN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR PATIENTS
    WUNDERLY, D
    MALONEY, J
    EDEL, T
    MCHENRY, M
    MCCARTHY, PM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (11): : 1360 - 1364
  • [44] Concerns about implantable cardioverter-defibrillator shocks mediate the relationship between actual shocks and psychological distress
    Thylen, Ingela
    Moser, Debra K.
    Stroemberg, Anna
    Dekker, Rebecca A.
    Chung, Misook L.
    EUROPACE, 2016, 18 (06): : 828 - 835
  • [45] Perceived control and quality of life among recipients of implantable cardioverter defibrillator
    Hammash, Muna
    McEvedy, Samantha M.
    Wright, Jesse
    Cameron, Jan
    Miller, Jennifer
    Ski, Chantal F.
    Thompson, David R.
    Biddle, Martha J.
    Wimsatt, Amy
    Schrader, Melanie
    Smith, Rachel Vickers
    Chung, Misook L.
    Moser, Debra K.
    AUSTRALIAN CRITICAL CARE, 2019, 32 (05) : 383 - 390
  • [46] Undertreatment of Anxiety and Depression in Patients With an Implantable Cardioverter-Defibrillator: Impact on Health Status
    Hoogwegt, Madelein T.
    Kupper, Nina
    Theuns, Dominic A. M. J.
    Zijlstra, Wobbe P.
    Jordaens, Luc
    Pedersen, Susanne S.
    HEALTH PSYCHOLOGY, 2012, 31 (06) : 745 - 753
  • [47] Psychological correlates, allostatic overload and clinical course in patients with implantable cardioverter defibrillator (ICD)
    Gostoli, Sara
    Bonomo, Matteo
    Roncuzzi, Renzo
    Biffi, Mauro
    Boriani, Giuseppe
    Rafanelli, Chiara
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 220 : 360 - 364
  • [48] Indications for an implantable cardioverter/defibrillator
    Schwab, J. O.
    INTERNIST, 2007, 48 (07): : 715 - 723
  • [49] Effect of physical and psychocognitive function and perceived health status on 12-month adverse cardiac events among implantable cardioverter-defibrillator recipients
    Kim, JinShil
    Choi, Jiin
    Shin, Mi-Seung
    Park, Jin-Kyu
    An, Minjeong
    Kim, Sun Hwa
    Choi, Nayeon
    Lee, Mee Ok
    Heo, Seongkum
    HEART & LUNG, 2020, 49 (05): : 530 - 536
  • [50] Depression and anxiety status of patients with implantable cardioverter defibrillator and precipitating factors
    Bilge, Ahmet Kaya
    Ozben, Beste
    Demircan, Sabri
    Cinar, Mutlu
    Yilmaz, Ercument
    Adalet, Kamil
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (06): : 619 - 626