Trajectories of Perceived Emotional and Physical Distress in Patients with an Implantable Cardioverter Defibrillator

被引:15
|
作者
van den Broek, Krista C. [1 ]
Kupper, Nina [1 ]
van der Voort, Pepijn H. [2 ]
Alings, Marco [3 ]
Denollet, Johan [1 ]
Nyklicek, Ivan [1 ]
机构
[1] Tilburg Univ, CoRPS Ctr Res Psychol Somat Dis, Dept Med Psychol, NL-5000 LE Tilburg, Netherlands
[2] Catharina Hosp, Dept Cardiol, Eindhoven, Netherlands
[3] Amphia Hosp, Dept Cardiol, Breda, Netherlands
关键词
Implantable cardioverter defibrillator; Anxiety; Depression; Health Status; Personality; QUALITY-OF-LIFE; RANDOMIZED CONTROLLED-TRIAL; CORONARY-HEART-DISEASE; D PERSONALITY; SECONDARY PREVENTION; ANXIETY SENSITIVITY; NEGATIVE AFFECTIVITY; CENTERED OUTCOMES; HEALTH COMPLAINTS; SOCIAL INHIBITION;
D O I
10.1007/s12529-012-9275-9
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
Background Little is known about the course of emotional and physical distress in patients with an implantable cardioverter defibrillator (ICD). Purpose We examined (1) trajectories of emotional and physical distress in the first 18 months postimplantation and (2) predictors of these trajectories, including demographical, clinical, and personality factors. Methods Dutch patients with an ICD (N = 645) completed measures on anxiety, depression, somatic symptoms, and perceived disability at the time of implantation, and 2, 12, and 18 months postimplantation. Measures on Type D personality (tendency to inhibit the expression of negative emotions) and anxiety sensitivity (tendency to fear anxiety-related sensations) were also completed at baseline. Results Latent class analysis (LatentGOLD) identified six to seven distinct trajectories, varying largely in overall levels of distress, and remaining relatively stable after a small initial decline. Multinomial regression showed that Type D personality and anxiety sensitivity were the most prominent predictors, particularly of trajectories that reflected higher distress levels. Cardiac resynchronization therapy and coronary artery disease also increased the risk for distress, whereas ICD indication and shocks did not. Conclusions The course of emotional and physical distress may be relatively stable after ICD implantation. In clinical practice, identification of patients with high risk of higher levels of emotional and physical distress may be warranted; as such, patients with high levels of anxiety sensitivity or a Type D personality should be identified and offered behavioral support.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [21] Pre implantation psychological functioning preserved in majority of implantable cardioverter defibrillator patients 12 months post implantation
    Pedersen, Susanne S.
    Hoogwegt, Madelein T.
    Jordaens, Luc
    Theuns, Dominic A. M. J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 215 - 220
  • [22] Anxiety and Risk of Ventricular Arrhythmias or Mortality in Patients With an Implantable Cardioverter Defibrillator
    Habibovic, Mirela
    Pedersen, Susanne S.
    van den Broek, Krista C.
    Theuns, Dominic A. M. J.
    Jordaens, Luc
    van der Voort, Pepijn H.
    Alings, Marco
    Denollet, Johan
    PSYCHOSOMATIC MEDICINE, 2013, 75 (01): : 36 - 41
  • [23] Monitoring Device Acceptance in Implantable Cardioverter Defibrillator Patients Using the Florida Patient Acceptance Survey
    Versteeg, Henneke
    Starrenburg, Annemieke
    Denollet, Johan
    Van der Palen, Job
    Sears, Samuel F.
    Pedersen, Susanne S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (03): : 283 - 293
  • [24] Uncovering Phantom Shocks in Cardiac Patients with an Implantable Cardioverter Defibrillator
    Bilanovic, Ana
    Irvine, Jane
    Kovacs, Adrienne H.
    Hill, Ann
    Cameron, Doug
    Katz, Joel
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (06): : 673 - 683
  • [25] Quality of Life and Psychological Factors in Patients with Implantable Cardioverter Defibrillator
    Suyama-Chishaki, Akiko
    Miyazono, Mami
    Tsuchihashi-Makaya, Miyuki
    Chishaki, Hiroaki
    Inoue, Syujiro
    Mukai, Yasushi
    Takemoto, Masao
    Kaji, Ryoichi
    Koike, George
    Maruyama, Toru
    Sunagawa, Kenji
    Arimura, Tatsuyuki
    Kubo, Chiharu
    JOURNAL OF ARRHYTHMIA, 2007, 23 (04) : 269 - 276
  • [26] Aerobic Exercise Effects on Quality of Life and Psychological Distress After an Implantable Cardioverter Defibrillator
    Dougherty, Cynthia M.
    Burr, Robert L.
    Kudenchuk, Peter J.
    Glenny, Robb W.
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2020, 40 (02) : 94 - 101
  • [27] Posttraumatic stress in implantable cardioverter defibrillator patients: The role of pre-implantation distress and shocks
    Versteeg, Henneke
    Theuns, Dominic A. M. J.
    Erdman, Ruud A. M.
    Jordaens, Luc
    Pedersen, Susanne S.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (03) : 438 - 439
  • [28] Sleep disturbance in patients with an implantable cardioverter defibrillator: Prevalence, predictors and impact on health status
    Habibovic, M.
    Mudde, L.
    Pedersen, S. S.
    Schoormans, D.
    Widdershoven, J.
    Denollet, J.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2018, 17 (05) : 390 - 398
  • [29] Living with an implantable cardioverter defibrillator: patients' preferences and needs for information provision and care options
    Pedersen, Susanne S.
    Knudsen, Charlotte
    Dilling, Karen
    Sandgaard, Niels C. F.
    Johansen, Jens Brock
    EUROPACE, 2017, 19 (06): : 983 - 990
  • [30] Cross-sectional study on the impact of adverse childhood experiences on psychological distress in patients with an implantable cardioverter-defibrillator
    Dorner, Marc
    von Kanel, Roland
    Pazhenkottil, Aju P.
    Altwegg, Rahel
    Konig, Noelle
    Nager, Ladina
    Attanasio, Veronica
    Guth, Lisa
    Zirngast, Sina
    Menzi, Anna
    Princip, Mary
    Zuccarella-Hackl, Claudia
    JOURNAL OF PSYCHOSOMATIC RESEARCH, 2025, 189