This paper presents a nuclear case study, in which a fuzzy inference system (FIS) is used as alternative approach in risk analysis. The main objective of this study is to obtain an understanding of the aging process of an important nuclear power system and how it affects the overall plant safety. This approach uses the concept of a pure fuzzy logic system where the fuzzy rule base consists of a collection of fuzzy IF - THEN rules. The fuzzy inference engine uses these fuzzy IF - THEN rules to determine a mapping from fuzzy sets in the input universe of discourse to fuzzy sets in the output universe of discourse based on fuzzy logic principles. The risk priority number (RPN), a traditional analysis parameter, was calculated and compared to fuzzy risk priority number (FRPN) using scores from expert opinion to probabilities of occurrence, severity and not detection. A standard four-loop pressurized water reactor (PWR) containment cooling system (CCS) was used as example case. The results demonstrated the potential of the inference system for subsiding the failure modes and effects analysis (FMEA) in aging studies. (C) 2005 Elsevier B.V. All rights reserved.
机构:
Liverpool John Moores Univ, Sch Engn Technol & Maritime Operat, Liverpool L3 3AF, Merseyside, EnglandLiverpool John Moores Univ, Sch Engn Technol & Maritime Operat, Liverpool L3 3AF, Merseyside, England
Yang, Zaili
Wang, Jin
论文数: 0引用数: 0
h-index: 0
机构:
Liverpool John Moores Univ, Sch Engn Technol & Maritime Operat, Liverpool L3 3AF, Merseyside, EnglandLiverpool John Moores Univ, Sch Engn Technol & Maritime Operat, Liverpool L3 3AF, Merseyside, England