The first technique for non-invasive measurements of volumetric ophthalmic artery blood flow in humans

被引:23
作者
Orge, F
Harris, A [1 ]
Kagemann, L
Kopecky, K
Sheets, CW
Rechtman, E
Zalish, M
机构
[1] Indiana Univ, Sch Med, Dept Ophthalmol, Indianapolis, IN 46202 USA
[2] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN USA
[3] Indiana Univ, Sch Med, Dept Physiol, Indianapolis, IN USA
[4] Hebrew Univ Jerusalem, Kaplan Med Ctr, Dept Ophthalmol, Sch Med, Jerusalem, Israel
关键词
D O I
10.1136/bjo.86.11.1216
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To validate the first non-invasive measurements of volumetric ophthalmic artery blood flow in humans. Methods: The ophthalmic arteries of healthy normal adults were examined by Advanced Technology Laboratories (ATL, a subsidiary of Phillips Medical Systems Inc) high definition imaging (HDI) 5000 colour Doppler imaging ultrasound with a 5-12 MHZ probe. A group of 14 subjects for experiment 1 and a group of 10 subjects for experiments 2 and 3 were selected, with the examined eye chosen randomly. Peak systolic velocities (PSV) and end diastolic velocities (EDV) of the ophthalmic artery and central retinal artery were measured and recorded. Cineloops (cinegraphic videos) of the ophthalmic arteries were then recorded with the ATL HDI 5000 and values for ophthalmic artery blood flow were produced offline using experimental analysis software. Multiple regression analysis was used to compare blood flow measurements with PSV and EDV measurements in the ophthalmic artery. In two follow up experiments, intraobserver variation in obtaining cineloops and the interanalyser variability in cineloop analysis were studied. Results: Volumetric flow correlated with ophthalmic artery PSV and EDV (p = 0.02, r(2) = 0.5). There was no correlation with the cental retinal artery. The intraobserver coefficient of variation in obtaining cineloops was 29.89% for blood flow, 19.07% for diameter, and 22.27% for velocity. The coefficients of variation of the measurements of the two cineloop analysers were 40.21% for blood flow, 22.71% for diameter, and 26.34% for velocity. Conclusion: Cineloop analysis produces ophthalmic artery flow measurements which correlate with PSV and EDV, suggesting validity. The intraobserver variation and cineloop analyser variation were found to be in the acceptable range.
引用
收藏
页码:1216 / 1219
页数:4
相关论文
共 16 条
[1]   PULSED ULTRASONIC DOPPLER BLOOD-FLOW SENSING [J].
BAKER, DW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1970, SU17 (03) :170-&
[2]  
BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
[3]  
Field JP., 1989, J VASC TECH, V13, P13
[4]   UMBILICAL VENOUS FLOW IN NORMAL AND COMPLICATED PREGNANCY [J].
GILL, RW ;
KOSSOFF, G ;
WARREN, PS ;
GARRETT, WJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (03) :349-363
[5]  
HOKANSON DE, 1971, BIOMED ENG, V6, P420
[6]   Lower extremity volumetric arterial blood flow in normal subjects [J].
Holland, CK ;
Brown, JM ;
Scoutt, LM ;
Taylor, KJW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (08) :1079-1086
[7]  
HOLLAND CK, 1993, ADV ULTRASOUND TECHN, P125
[8]  
JOGER KA, 1985, NONINVASIVE DIAGNOST, P619
[9]   MEASUREMENT OF VOLUME FLOW IN THE HUMAN COMMON FEMORAL-ARTERY USING A DUPLEX ULTRASOUND SYSTEM [J].
LEWIS, P ;
PSAILA, JV ;
DAVIES, WT ;
MCCARTY, K ;
WOODCOCK, JP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (10) :777-784
[10]  
Michelson G, 1991, Fortschr Ophthalmol, V88, P687