Near-Infrared Diffuse Reflectance Measurement Method Based on Temperature-Insensitive Radial Distance

被引:3
作者
Wu, Minglei [1 ]
Liu, Rong [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
Near-infrared diffuse reflectance; temperature; absorption coefficient; scattering coefficient; temperature-insensitive radial distance; WAVELENGTH RANGE; GLUCOSE; SPECTROSCOPY; WATER; NM;
D O I
10.1177/0003702818766555
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The variation of temperature is one of the main interference factors that affect the detection accuracy of near-infrared (NIR) diffuse reflectance. In this paper, a measurement method based on temperature-insensitive radial distance was proposed, and its feasibility and effectiveness were verified in Intralipid solutions. First, the possibility of temperature-insensitive radial distance was deduced based on the analytic solution of the steady-state diffusion equation in an infinite media, and the temperature-insensitive radial distances of 3% Intralipid solution in the wavelength range of 1000-1600nm was calculated. Second, a detection system was designed to measure the diffuse reflectance of 3% Intralipid solutions at multiple radial distances with different glucose concentration (0-100mM) and different temperatures (35-40?). Both theoretical calculations and experimental results demonstrated the existence of temperature-insensitive radial distances in the range of 1000-1340nm and 1440-1600nm, and the distances were hardly affected by glucose variations. Finally, the glucose information extracted from the diffuse reflectance of Intralipid solutions at different radial distances under random temperature variations and constant temperature were compared. The result showed that the correlation between the glucose concentration and the diffuse reflectance obtained at the temperature-insensitive radial distance was significantly better than that of other radial distances, which was almost close to the situation of constant temperature. Therefore, the measurement method based on temperature-insensitive radial distance can effectively reduce the influence of temperature variations on NIR diffuse reflectance, and it is expected to improve the accuracy of diffuse reflectance in human body components detection and industrial field analysis.
引用
收藏
页码:1021 / 1028
页数:8
相关论文
共 19 条
  • [11] Measuring optical temperature coefficients of Intralipid®
    McGlone, V. Andrew
    Martinsen, Paul
    Kunnemeyer, Rainer
    Jordan, Bob
    Cletus, Biju
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09) : 2367 - 2378
  • [12] Qu J Y, 1997, J Biomed Opt, V2, P319, DOI 10.1117/12.275453
  • [13] LIGHT DOSIMETRY IN OPTICAL PHANTOMS AND IN TISSUES .1. MULTIPLE FLUX AND TRANSPORT-THEORY
    STAR, WM
    MARIJNISSEN, JPA
    VANGEMERT, MJC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (04) : 437 - 454
  • [14] Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
    Troy, TL
    Thennadil, SN
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) : 167 - 176
  • [15] LIGHT-SCATTERING IN INTRALIPID-10-PERCENT IN THE WAVELENGTH RANGE OF 400-1100 NM
    VANSTAVEREN, HJ
    MOES, CJM
    VANMARLE, J
    PRAHL, SA
    VANGEMERT, MJC
    [J]. APPLIED OPTICS, 1991, 30 (31): : 4507 - 4514
  • [16] Correction of temperature-induced spectral variation by continuous piecewise direct standardization
    Wulfert, F
    Kok, WT
    de Noord, OE
    Smilde, AK
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1639 - 1644
  • [17] Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 214 - 227
  • [18] Reference point of floating-reference method for blood glucose sensing
    Yang, Yue
    Chen, Wenliang
    Shi, Zhenzhi
    Xu, Kexin
    [J]. CHINESE OPTICS LETTERS, 2010, 8 (04) : 421 - 424
  • [19] Zhang X., 2009, Proceedings of SPIE, p74711R