Comparative Study of Ion Interaction Reagents for the Separation of Lanthanides by Reversed-Phase High Performance Liquid Chromatography (RP-HPLC)

被引:10
|
作者
Jaison, P. G. [1 ]
Kumar, Pranaw [1 ]
Telmore, Vijay M. [1 ]
Aggarwal, Suresh K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
HPLC; Ion interaction reagents; Lanthanides; Modification; Resolution; Reversed-phase; RARE-EARTH-ELEMENTS; URANIUM-DIOXIDE FUELS; METAL-IONS; EXCHANGE CHROMATOGRAPHY; GEOLOGICAL SAMPLES; COATED COLUMNS; HIGH-PURITY; THORIUM; GABON; MASS;
D O I
10.1080/10826070903163230
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A study of two ion interaction reagents (IIRs) viz. n-octadecane sulphonate (C-18-sulphonate) and eicosyl sulphate (C-20-sulphate) was carried out for the separation of lanthanides by reversed-phase high performance liquid chromatography (RP-HPLC). The objective of the study was to identify a suitable IIR offering long term adsorption onto the RP column, thereby obviating the need to introduce the IIR in the mobile phase during the separation of lanthanides. This avoids the rigorous treatment of purified fractions before their mass spectrometric analysis. Resolution was used for comparing different IIRs for separation of lanthanides under identical chromatographic conditions, employing alpha-hydroxy isobutyric acid (alpha-HIBA) as an eluent. The volume and composition of IIR solution required for the modification of the column, as well as their long term adsorption, were studied. Columns coated with C-18-sulphonate and C-20-sulphate allowed the separation of lanthanides without introducing the IIR in the mobile phase. Between these two IIRs, C-18-sulphonate offered higher resolution and provided good long term adsorption stability. A RP column modified with C-18-sulphonate, as per the optimised procedure, was used for the separation of lanthanides from a geological reference sample without the need to include IIR into the mobile phase.
引用
收藏
页码:2146 / 2163
页数:18
相关论文
共 50 条
  • [41] Phosphorothioate oligonucleotides separation in ion-pairing reversed-phase liquid chromatography: Effect of ion-pairing system
    Kadlecova, Zuzana
    Kalikova, Kveta
    Tesarova, Eva
    Gilar, Martin
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1676
  • [42] Ion-pair Reversed-phase Liquid Chromatographic Separation of Oligonucleotides
    Takano, Takumi
    Aoyama, Chiaki
    Terasaki, Yoshiro
    Suzuki, Kenichi
    Ando, Aki
    Song, Yanting
    Tsunoda, Makoto
    ANALYTICAL SCIENCES, 2021, 37 (12) : 1811 - 1814
  • [43] Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography
    Wang, Jiafei
    Bai, Ligai
    Wei, Zhen
    Qin, Junxiao
    Ma, Yamin
    Liu, Haiyan
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2101 - 2108
  • [44] A comparison of selected methods for optimization of separation selectivity in reversed-phase liquid - Liquid chromatography
    Prus, W
    Kowalska, T
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 1995, 8 (04) : 288 - 291
  • [45] Urine iodide determination by ion-pair reversed-phase high performance liquid chromatography and pulsed amperometric detection
    Nguyen, Vo Thanh Phuong
    Piersoel, Virginie
    El Mahi, Tank
    TALANTA, 2012, 99 : 532 - 537
  • [46] INFLUENCE OF THE ELUENT COMPOSITION ON RETENTION IN REVERSED PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)
    王俊德
    李景芝
    姚荣余
    卢佩章
    Science in China,SerB, 1985, Ser.B1985 (07) : 680 - 687
  • [47] A study of the scale-up of reversed-phase liquid chromatography
    Gu, T
    Zheng, Y
    SEPARATION AND PURIFICATION TECHNOLOGY, 1999, 15 (01) : 41 - 58
  • [48] Reversed-Phase-Reversed-Phase Liquid Chromatography Approach with High Orthogonality for Multidimensional Separation of Phosphopeptides
    Song, Chunxia
    Ye, Mingliang
    Han, Guanghui
    Jiang, Xinning
    Wang, Fangjun
    Yu, Zhiyuan
    Chen, Rui
    Zou, Hanfa
    ANALYTICAL CHEMISTRY, 2010, 82 (01) : 53 - 56
  • [49] Simultaneous Determination of Cysteamine and Cystamine in Cosmetics by Ion-Pairing Reversed-Phase High-Performance Liquid Chromatography
    Kim, Yejin
    Na, Dong Hee
    TOXICOLOGICAL RESEARCH, 2019, 35 (02) : 161 - 165
  • [50] High performance liquid chromatographic studies on lanthanides, uranium and thorium on amide modified reversed phase supports
    Maheswari, M. Akhila
    Prabhakaran, D.
    Subramanian, M. S.
    Sivaraman, N.
    Srinivasan, T. G.
    Rao, P. R. Vasudeva
    TALANTA, 2007, 72 (02) : 730 - 740