Comparative Study of Ion Interaction Reagents for the Separation of Lanthanides by Reversed-Phase High Performance Liquid Chromatography (RP-HPLC)

被引:10
|
作者
Jaison, P. G. [1 ]
Kumar, Pranaw [1 ]
Telmore, Vijay M. [1 ]
Aggarwal, Suresh K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
HPLC; Ion interaction reagents; Lanthanides; Modification; Resolution; Reversed-phase; RARE-EARTH-ELEMENTS; URANIUM-DIOXIDE FUELS; METAL-IONS; EXCHANGE CHROMATOGRAPHY; GEOLOGICAL SAMPLES; COATED COLUMNS; HIGH-PURITY; THORIUM; GABON; MASS;
D O I
10.1080/10826070903163230
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A study of two ion interaction reagents (IIRs) viz. n-octadecane sulphonate (C-18-sulphonate) and eicosyl sulphate (C-20-sulphate) was carried out for the separation of lanthanides by reversed-phase high performance liquid chromatography (RP-HPLC). The objective of the study was to identify a suitable IIR offering long term adsorption onto the RP column, thereby obviating the need to introduce the IIR in the mobile phase during the separation of lanthanides. This avoids the rigorous treatment of purified fractions before their mass spectrometric analysis. Resolution was used for comparing different IIRs for separation of lanthanides under identical chromatographic conditions, employing alpha-hydroxy isobutyric acid (alpha-HIBA) as an eluent. The volume and composition of IIR solution required for the modification of the column, as well as their long term adsorption, were studied. Columns coated with C-18-sulphonate and C-20-sulphate allowed the separation of lanthanides without introducing the IIR in the mobile phase. Between these two IIRs, C-18-sulphonate offered higher resolution and provided good long term adsorption stability. A RP column modified with C-18-sulphonate, as per the optimised procedure, was used for the separation of lanthanides from a geological reference sample without the need to include IIR into the mobile phase.
引用
收藏
页码:2146 / 2163
页数:18
相关论文
共 50 条
  • [1] Analysis of R-Limonene separation in RP-HPLC (reversed-phase high-performance liquid chromatography) by Moment method and Van Deemter equation
    Kwan-Young Ko
    In Su Lee
    In-Ho Kim
    Biotechnology and Bioprocess Engineering, 2015, 20 : 585 - 592
  • [2] Analysis of R-limonene Separation in RP-HPLC (Reversed-Phase High-Performance Liquid Chromatography) by Moment Method and Van Deemter Equation
    Ko, Kwan-Young
    Lee, In Su
    Kim, In-Ho
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2015, 20 (03) : 585 - 592
  • [3] Comparative evaluation of three α-hydroxycarboxylic acids for the separation of lanthanides by dynamically modified reversed-phase high-performance liquid chromatography
    Raut, NM
    Jaison, PG
    Aggarwal, SK
    JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) : 163 - 172
  • [4] Development of a reversed-phase high performance liquid chromatography (RP-HPLC) procedure for the simultaneous determination of phenolic compounds in peanut skin extracts
    Francisco, Maria Leonora dL.
    Resurreccion, A. V. A.
    FOOD CHEMISTRY, 2009, 117 (02) : 356 - 363
  • [5] Analysis of Cyclic Adenosine Monophosphate (cAMP) Separation via RP-HPLC (reversed-phase high-performance liquid chromatography) by the Moment Method and the van Deemter Equation
    Lee, Il Song
    Ko, Kwan Young
    Kim, In Ho
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2015, 53 (06): : 723 - 729
  • [6] Rapid and Simple Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Simultaneous Quantifications of Triazole Antifungals in Human Serum
    Hansraj Choudhary
    Shreya Singh
    Rachna Singh
    Ritesh Agarwal
    Harsimran Kaur
    Anup Ghosh
    Arunaloke Chakrabarti
    Shivaprakash M. Rudramurthy
    Mycopathologia, 2021, 186 : 27 - 39
  • [7] Stationary phases for reversed phase high performance liquid chromatography (RP-HPLC) based on functionalized inorganic oxide surfaces.
    Tonhi, E
    Collins, KE
    Jardim, ICSF
    Collins, CH
    QUIMICA NOVA, 2002, 25 (04): : 616 - 623
  • [8] QUANTITATIVE DETERMINATION OF ETORICOXIB AND PARACETAMOL IN PHARMACEUTICAL DOSAGE FORM AND IN-VITRO COMPARISON BY REVERSED-PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (RP-HPLC)
    Zaveri, Maitreyi
    Khandhar, Amit
    ASIAN JOURNAL OF PHARMACEUTICAL RESEARCH AND HEALTH CARE, 2010, 2 (04) : 307 - 313
  • [9] Rapid and Simple Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method for Simultaneous Quantifications of Triazole Antifungals in Human Serum
    Choudhary, Hansraj
    Singh, Shreya
    Singh, Rachna
    Agarwal, Ritesh
    Kaur, Harsimran
    Ghosh, Anup
    Chakrabarti, Arunaloke
    Rudramurthy, Shivaprakash M.
    MYCOPATHOLOGIA, 2021, 186 (01) : 27 - 39
  • [10] Separation and determination of lanthanides, thorium and uranium using a dual gradient in reversed-phase liquid chromatography
    Raut, NM
    Jaison, PG
    Aggarwal, SK
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) : 131 - 136