Efficient hydrazine electrochemical sensor based on PANI doped mesoporous SrTiO3 nanocomposite modified glassy carbon electrode

被引:44
作者
Faisal, M. [1 ,2 ]
Rashed, Md. A. [1 ,4 ]
Abdullah, M. M. [1 ,5 ]
Harraz, Farid A. [1 ,3 ]
Jalalah, Mohammed [1 ,6 ]
Al-Assiri, M. S. [1 ,5 ]
机构
[1] Najran Univ, Adv Mat & Nanores Ctr, Promising Ctr Sensors & Elect Devices PCSED, POB 1988, Najran 11001, Saudi Arabia
[2] Najran Univ, Fac Sci & Arts, Dept Chem, Najran, Saudi Arabia
[3] Cent Met Res & Dev Inst CMRDI, Nanomat & Nanotechnol Dept, PO 87, Cairo 11421, Egypt
[4] Mawlana Bhashani Sci & Technol Univ, Dept Chem, Fac Sci, Santosh 1902, Tangail, Bangladesh
[5] Najran Univ, Dept Phys, Fac Sci & Arts, Najran, Saudi Arabia
[6] Najran Univ, Dept Elect Engn, Fac Engn, Najran, Saudi Arabia
关键词
Conducting polymer; SrTiO3; nanocomposite; Sol-gel; Hydrazine electrochemical sensor; Amperometry; SELECTIVE AMPEROMETRIC SENSOR; LOW-TEMPERATURE; ELECTROCATALYTIC OXIDATION; METAL-OXIDE; CONDUCTING POLYANILINE; STRONTIUM-TITANATE; NANOPARTICLES; FILM; PHTHALOCYANINE; FABRICATION;
D O I
10.1016/j.jelechem.2020.114805
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, an electrochemical approach was developed for the rapid and selective determination of hydrazine using 5% polyaniline (PANI)-doped mesoporous SrTiO3 nanocomposite modified glassy carbon electrode (GCE). The nanocomposite was synthesized by a modified sol-gel procedure using F127 structure mediator agent to obtain mesoporous SrTiO3 followed by an ultra-sonication technique to produce the final PANI doped SrTiO3. Various characterization tools, namely, XRD, XPS, FE-SEM and HR-TEM confirmed the successful formation of the nanocomposite and revealed cubic perovskite structure with d-spacing value 2.70 angstrom for mesoporous SrTiO3. Cyclic voltammetry and electrochemical impedance spectroscopy measurements exhibited higher electrocatalytic performance of the PANI/SrTiO3 nanocomposite compared to either pure SrTiO3 or unmodified GCE. The hydrazine oxidation reaction follows the first-order diffusion-controlled kinetics with a transfer coefficient value 0.65 obtained from Tafel plot analysis. Linear sweep voltammetry (LSV) and amperometric (i-t) techniques revealed that the PANI/SrTiO3 nanocomposite modified GCE exhibited remarkable sensitivity; 0.2128 mu A mu M-1 cm(-2) over the concentration range 0.2-3.56 mM (LSV) and 0.2438 mu A mu M-1 cm(-2) over the concentration range 16-58 mu M (amperometry) with a rapid response time < 10s. The limit of detection (LOD) was estimated to be 1.09 mu M and 0.95 mu M at (S/N = 3) for LSV and amperometric technique, respectively. Additionally, the modified electrode demonstrated excellent anti-interfering ability in the presence of various common active species as well as exhibited good operational stability and sutability for the real sample analysis. Such developed PANI/SrTiO3 nanocomposite represents an excellent electro-catalyst for efficient detection and quantification of hydrazine by the electrochemical approach.
引用
收藏
页数:13
相关论文
共 50 条
[31]   Electrochemical sensor for amino acids based on gold nanoparticles/macroporous carbon composites modified glassy carbon electrode [J].
Zeng, Lijun ;
Wang, Huan ;
Bo, Xiangjie ;
Guo, Liping .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 687 :117-122
[32]   A novel hydrazine electrochemical sensor based on a zirconium hexacyanoferrate film-bimetallic Au-Pt inorganic-organic hybrid nanocomposite onto glassy carbon-modified electrode [J].
Gholivand, Mohammad Bagher ;
Azadbakht, Azadeh .
ELECTROCHIMICA ACTA, 2011, 56 (27) :10044-10054
[33]   An electrochemical sensor for the determination of tartrazine based on CHIT/GO/MWCNTs/AuNPs composite film modified glassy carbon electrode [J].
Rovina, Kobun ;
Siddiquee, Shafiquzzaman ;
Md Shaarani, Sharifudin .
DRUG AND CHEMICAL TOXICOLOGY, 2021, 44 (05) :447-457
[34]   CuX/Sulfur-Doped C3N4 Nanocomposite-Modified Glassy Carbon Electrode for Electrochemical Detection of Dopamine [J].
Batish, Shikha ;
Rajput, Jaspreet Kaur .
ACS APPLIED NANO MATERIALS, 2024, 7 (13) :15104-15115
[35]   Hydrazine sensors development based on a glassy carbon electrode modified with a nanostructured TiO2 films by electrochemical approach [J].
Rahman, Mohammed M. ;
Alfonso, Valero G. ;
Fabregat-Santiago, Francisco ;
Bisquert, Juan ;
Asiri, Abdullah M. ;
Alshehri, Abdelmohsen A. ;
Albar, Hassan A. .
MICROCHIMICA ACTA, 2017, 184 (07) :2123-2129
[36]   Electrochemical Sensor for Caffeine Based on a Glassy Carbon Electrode Modified with an Attapulgite/Nafion Film [J].
Tajeu, Kevin Yemele ;
Ymele, Ervice ;
Jiokeng, Sherman Lesly Zambou ;
Tonle, Ignas Kenfack .
ELECTROANALYSIS, 2019, 31 (02) :350-356
[37]   Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites [J].
Cui, Fei ;
Zhang, Xiaoli .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 :35-41
[38]   Electrochemical sensor for formaldehyde based on Pt–Pd nanoparticles and a Nafion-modified glassy carbon electrode [J].
Zhong-Liang Zhou ;
Tian-Fang Kang ;
Yan Zhang ;
Shui-Yuan Cheng .
Microchimica Acta, 2009, 164 :133-138
[39]   A hydroxylamine electrochemical sensor based on electrodeposition of platinum nanoclusters on choline film modified glassy carbon electrode [J].
Li, Jing ;
Xie, Huaqing .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (04) :271-277
[40]   A Facile Hydrazine Amperometric Sensor Based on a Glassy Carbon Electrode Modified with Au Nanoparticles-MnO2 Composites [J].
Wang, Mei-Fang ;
Li, Wei ;
Hu, Ping-Jing ;
He, Shuang-Shuang ;
Yang, Hong-Mei ;
Li, Xiang-Zi .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (03) :1928-1937