Utility of fusion volumetric images from computed tomography and magnetic resonance imaging for localizing the mandibular canal

被引:14
作者
Deepho, Chutamas [1 ]
Watanabe, Hiroshi [1 ]
Kotaki, Shinya [1 ]
Sakamoto, Junichiro [1 ]
Sumi, Yasunori [2 ]
Kurabayashi, Tohru [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Dept Oral & Maxillofacial Radiol, Tokyo, Japan
[2] Natl Ctr Geriatr & Gerontol, Natl Ctr Adv Med Dent & Oral Dis, Obu, Japan
基金
日本学术振兴会;
关键词
MRI; mandible; multislice CT; imaging; three-dimensional; BREATH-HOLD EXAMINATION; ACCURACY; VISIBILITY; POSITION;
D O I
10.1259/dmfr.20160383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to investigate whether CT/MRI fusion volumetric images can improve the detectability of the mandibular canal (MC) compared with CT alone. Methods: Images of 31 lesions within or close to the mandible using both multislice CT (MSCT) and MRI were gathered from our imaging archives. All lesions underwent MSCT and three-dimensional volumetric interpolated breath-hold examination (3D-VIBE) MRI. Of the 62 hemimandibles, 13 hemimandibles were excluded because theMC passed through a lesion. The remaining 49 hemimandibles were included in this study. Each hemimandible was divided into 3 areas (premolar, molar and retromolar), and 147 areas were evaluated. First, the visibility of theMC on CT or its neurovascular bundle (NVB) on 3D-VIBE was evaluated. Second, in areas in which both the MC and NVB were visible, the relative locations of the NVB on MRI and the position of the MC on CT were assessed using CT/MRI fusion volumetric images. Results: The MC and NVB were clearly visible in 100 (68%) and 144 (98%) of 147 areas on CT and MRI, respectively. All NVBs and MCs were in identical locations, and the NVB on MRI was the same size or smaller than the MC on CT in 79 and 21 areas, respectively. Conclusions: 3D-VIBE MRI can accurately depict the NVB. Compared with CT alone, CT/MRI fusion volumetric imaging improves MC detectability.
引用
收藏
页数:8
相关论文
共 14 条
[11]   Assessment of the Visibility and Characteristics of the Mandibular Incisive Canal: Cone Beam Computed Tomography Versus Panoramic Radiography [J].
Sahman, Halil ;
Sekerci, Ahmet Ercan ;
Sisman, Yildiray ;
Payveren, Mehtap .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) :71-78
[12]   Evaluation of the Mandibular Canal Visibility on Cone-Beam Computed Tomography Images of the Mandible [J].
Shokri, Abbas ;
Shakibaei, Zahra ;
Langaroodi, Adineh Javadian ;
Safaei, Mehran .
JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) :E273-E277
[13]   Evaluation of the Inferior Alveolar Canal for Cysts and Tumors of the Mandible-Comparison of Multidetector Computed Tomography and 3-Dimensional Volume Interpolated Breath-Hold Examination Magnetic Resonance Sequence With Curved Multiplanar Reformatted Reconstructions [J].
Srinivasan, K. ;
Seith, Ashu ;
Gadodia, Ankur ;
Sharma, Raju ;
Kumar, Atin ;
Roychoudhury, Ajoy ;
Bhutia, Ongkila .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (10) :2327-2332
[14]   Localizing the mandibular canal on dental CT reformatted images: usefulness of panoramic views [J].
Takahashi, Akira ;
Watanabe, Hiroshi ;
Kamiyama, Yosuke ;
Honda, Eiichi ;
Sumi, Yasunori ;
Kurabayashi, Tohru .
SURGICAL AND RADIOLOGIC ANATOMY, 2013, 35 (09) :803-809