Utility of fusion volumetric images from computed tomography and magnetic resonance imaging for localizing the mandibular canal

被引:14
作者
Deepho, Chutamas [1 ]
Watanabe, Hiroshi [1 ]
Kotaki, Shinya [1 ]
Sakamoto, Junichiro [1 ]
Sumi, Yasunori [2 ]
Kurabayashi, Tohru [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Dept Oral & Maxillofacial Radiol, Tokyo, Japan
[2] Natl Ctr Geriatr & Gerontol, Natl Ctr Adv Med Dent & Oral Dis, Obu, Japan
基金
日本学术振兴会;
关键词
MRI; mandible; multislice CT; imaging; three-dimensional; BREATH-HOLD EXAMINATION; ACCURACY; VISIBILITY; POSITION;
D O I
10.1259/dmfr.20160383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to investigate whether CT/MRI fusion volumetric images can improve the detectability of the mandibular canal (MC) compared with CT alone. Methods: Images of 31 lesions within or close to the mandible using both multislice CT (MSCT) and MRI were gathered from our imaging archives. All lesions underwent MSCT and three-dimensional volumetric interpolated breath-hold examination (3D-VIBE) MRI. Of the 62 hemimandibles, 13 hemimandibles were excluded because theMC passed through a lesion. The remaining 49 hemimandibles were included in this study. Each hemimandible was divided into 3 areas (premolar, molar and retromolar), and 147 areas were evaluated. First, the visibility of theMC on CT or its neurovascular bundle (NVB) on 3D-VIBE was evaluated. Second, in areas in which both the MC and NVB were visible, the relative locations of the NVB on MRI and the position of the MC on CT were assessed using CT/MRI fusion volumetric images. Results: The MC and NVB were clearly visible in 100 (68%) and 144 (98%) of 147 areas on CT and MRI, respectively. All NVBs and MCs were in identical locations, and the NVB on MRI was the same size or smaller than the MC on CT in 79 and 21 areas, respectively. Conclusions: 3D-VIBE MRI can accurately depict the NVB. Compared with CT alone, CT/MRI fusion volumetric imaging improves MC detectability.
引用
收藏
页数:8
相关论文
共 14 条
[1]  
Anson C, 2012, CLIN ORAL IMPLAN RES, V23, P253
[2]   Geometric accuracy of magnetic resonance imaging of the mandibular nerve [J].
Eggers, G ;
Rieker, M ;
Fiebach, J ;
Kress, B ;
Dickhaus, H ;
Hassfeld, S .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (05) :285-291
[3]   Registration Accuracy of CT/MRI Fusion for Localisation of Deep Brain Stimulation Electrode Position: An Imaging Study and Systematic Review [J].
Geevarghese, Ruben ;
Tuura, Ruth O'Gorman ;
Lumsden, Daniel E. ;
Samuel, Michael ;
Ashkan, Keyoumars .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2016, 94 (03) :159-163
[4]   The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography [J].
Goto, Tazuko K. ;
Nishida, Satoko ;
Nakamura, Yuko ;
Tokumori, Kenji ;
Nakamura, Yasuhiko ;
Kobayashi, Koji ;
Yoshida, Yutaka ;
Yoshiura, Kazunori .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (04) :550-559
[5]  
Imamura Hideyuki, 2004, Clin Implant Dent Relat Res, V6, P75, DOI 10.1111/j.1708-8208.2004.tb00029.x
[6]   Radiographic evaluation of the course and visibility of the mandibular canal [J].
Jung, Yun-Hoa ;
Cho, Bong-Hae .
IMAGING SCIENCE IN DENTISTRY, 2014, 44 (04) :273-278
[7]   Location of the Mandibular Canal and the Topography of Its Neurovascular Structures [J].
Kim, Sung Tae ;
Hu, Kyung-Seok ;
Song, Wu-Chul ;
Kang, Min-Kyu ;
Park, Hyun-Do ;
Kim, Hee-Jin .
JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (03) :936-939
[8]   Comparative evaluation of mandibular canal visibility on cross-sectional cone-beam CT images: a retrospective study [J].
Miles, Mahogany S. ;
Parks, Edwin T. ;
Eckert, George J. ;
Blanchard, Steven B. .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (02)
[9]   Systematic review of preoperative mandibular canal position as it relates to postoperative neurosensory disturbance following the sagittal split ramus osteotomy [J].
Rich, J. ;
Golden, B. A. ;
Phillips, C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (09) :1076-1081
[10]   Abdominal MR imaging with a volumetric interpolated breath-hold examination [J].
Rofsky, NM ;
Lee, VS ;
Laub, G ;
Pollack, MA ;
Krinsky, GA ;
Thomasson, D ;
Ambrosino, MM ;
Weinreb, JC .
RADIOLOGY, 1999, 212 (03) :876-884