Determination of four antiepileptic drugs with solvent assisted dispersive solid phase microextraction - Gas chromatography-mass spectrometry in human urine samples

被引:18
作者
Mohammadi, Parisa [1 ]
Masrournia, Mahboubeh [1 ]
Es'haghi, Zarrin [2 ]
Pordel, Mehdi [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Mashhad Branch, Mashhad, Razavi Khorasan, Iran
[2] Payam Noor Univ, Dept Chem, Tehran, Iran
关键词
Antiepileptic drugs; Urine samples; Dispersive solid phase microextraction; GC-MS; LIQUID-LIQUID MICROEXTRACTION; VALPROIC ACID; NANOMATERIALS; EXTRACTION; PREGABALIN; SORBENTS; PRECONCENTRATION; WATER;
D O I
10.1016/j.microc.2020.105542
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper solvent assisted dispersive solid-phase microextraction (SA-DSPME) as a rapid and comprehensive sample preparation method was developed to extract and cleanup four antiepileptic drugs (AEDs); valproic acid, phenobarbital, levetiracetam, and pregabalin from human urine samples. In the procedure, the dispersion of the sorbent was attained by rapid injection of a mixture of the adsorbent and disperser solvent into the aqueous sample to increase the contact surface and reduce the extraction time and amount of sorbent consumption. Several sorbents such as magnetic Fe3O4, Fe3O4@graphene, Fe3O4@graphene oxide, Fe3O4@MWCNTs, Fe3O4@SiO2, Fe3O4@SiO2@TiO2, Fe3O4@Chitosan, and NiO NPs were tested to extract the target drugs and the results compared. Among them, Fe3O4@SiO2 was chosen as the best sorbent, and its structure characterized using FESEM, FTIR, and EDX. Besides, effective factors in the SA-DSPME, including the type of disperser solvent and desorption solvent, extraction time, desorption time, pH, and disperser solvent and desorption solvent volume, were optimized using one factor at a time and design experiment strategy. Under the optimum conditions, the calibration curves were linear in the range of 0.2-100 ng mL(-1) for valproic acid and phenobarbital, and 0.4-120 ng mL(-1) for levetiracetam and pregabalin. Limit of detections and limit of quantifications were lower than 0.11 and 0.4 ng mL(-1) for the analytes. Besides, the procedure showed suitable relative standard deviations (<= 3.8%) and preconcentration factors (>= 133.9) for the determination of the antiepilepsy drugs. Analysis of human urine samples confirmed that the SA-DSPME-GC procedure is an appropriate method for measuring the target drugs in biological samples with recoveries between 92.9 and 103.2 % and RSD less than 4.7%.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Simultaneous and rapid determination of three organophosphorus pesticides from vegetable and cereal samples with a magnetic dispersive solid-phase microextraction method by gas chromatography-mass spectrometry
    Sefati, Bahareh
    Masrournia, Mahboubeh
    Beheshti, Hamed Reza
    Feizy, Javad
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (19) : 7457 - 7473
  • [22] Solid-phase microextraction and gas chromatography-mass spectrometry for quantitative determination of chlordecone in water, plant and soil samples
    Soler, Alain
    Lebrun, Marc
    Labrousse, Yoan
    Wignier, Thierry
    [J]. FRUITS, 2014, 69 (04) : 325 - 339
  • [23] Rapid determination of alkylphenols in aqueous samples by in situ acetylation and microwave-assisted headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry
    Wu, Yu-Pei
    Wang, Yu-Chen
    Ding, Wang-Hsien
    [J]. JOURNAL OF SEPARATION SCIENCE, 2012, 35 (16) : 2122 - 2130
  • [24] PRELIMINARY RESULTS ON THE ANALYSIS OF STEROIDS IN POULTRY SAMPLES BY DIRECT IMMERSION SOLID-PHASE MICROEXTRACTION AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    Senila, Lacrimioara
    Miclean, Mirela
    Levei, Erika Andrea
    Roman, Cecilia
    Majdik, Cornelia
    [J]. STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2011, 56 (02): : 107 - 114
  • [25] Direct determination of methyl parathion insecticide in rice samples by headspace solid-phase microextraction-gas chromatography-mass spectrometry
    da Silva, Darlan Ferreira
    Paiva Silva, Francisco Eduardo
    Silva, Fernanda Gabrielle S.
    Nunes, Gilvanda Silva
    Badea, Mihaela
    [J]. PEST MANAGEMENT SCIENCE, 2015, 71 (11) : 1497 - 1502
  • [26] Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water
    Lina Gao
    Guojie Liu
    Juan Zhu
    Chunyuan Wang
    Junting Liu
    [J]. Journal of Analytical Chemistry, 2015, 70 : 552 - 557
  • [27] Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water
    Gao, Lina
    Liu, Guojie
    Zhu, Juan
    Wang, Chunyuan
    Liu, Junting
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 552 - 557
  • [28] Miniaturized hollow fiber assisted liquid-phase microextraction and gas chromatography-mass spectrometry for determination of benzophenone and derivates in human urine sample
    Kawaguchi, Migaku
    Ito, Rie
    Honda, Hidehiro
    Koganei, Youji
    Okanouchi, Noriya
    Saito, Koichi
    Seto, Yasuo
    Nakazawa, Hiroyuki
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 298 - 302
  • [29] Sensitive determination of toxaphene in textiles by Gas Chromatography-Mass Spectrometry with Solid-phase Microextraction
    Wu, Shuhuan
    Liu, Liqin
    Feng, Wen
    [J]. PROCEEDINGS OF THE FIBER SOCIETY 2009 SPRING CONFERENCE, VOLS I AND II, 2009, : 518 - 520
  • [30] Determination of organotin compounds in water by headspace solid phase microextraction with gas chromatography-mass spectrometry
    Chou, CC
    Lee, MR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1064 (01) : 1 - 8