Safety and efficacy of high power shorter duration ablation for atrial fibrillation: A systematic review and meta-analysis

被引:7
作者
Li, Miao-Fu [1 ]
Wu, Jing [2 ]
Jin, Chao-Lun [1 ]
Chen, Chao-Feng [2 ]
Xu, Yi-Zhou [1 ,2 ]
机构
[1] Nanjing Med Univ, Affiliated Hangzhou Peoples Hosp 1, Nanjing, Jiangshu, Peoples R China
[2] Hangzhou First Peoples Hosp, Dept Cardiol, Hangzhou, Zhejiang, Peoples R China
关键词
PULMONARY VEIN ISOLATION; CATHETER ABLATION; RADIOFREQUENCY; TARGETS; QUALITY; LESIONS; WALL;
D O I
10.1111/ijcp.13732
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Radiofrequency ablation in patients with atrial fibrillation (AF) is effective but hampered by pulmonary veins reconnection because of insufficient lesions. High power shorter duration ablation (HPSD) was seen to increase efficacy and safety. This analysis aimed to evaluate the clinical benefits of HPSD in patients with AF. Methods The Medline, PubMed, Embase, and the Cochrane Library databases were searched for studies comparing HPSD and Low power longer duration (LPLD) ablation. Results A total of seven trials with 2023 patients were included in the analysis. Pooled analyses demonstrated that HPSD showed a benefit of first-pass pulmonary vein isolation (PVI) [risk ratio (RR): 1.27; 95% confidence interval (CI): 1.18-1.37, P < .001]. HPSD could reduce recurrence of atrial arrhythmias (RR: 0.70; 95% CI: 0.50-0.98, P = .04). Additionally, HPSD was more beneficial in terms of procedural time [Weighted Mean Difference, (WMD): -44.62; 95% CI, -63.00 to -26.23, P < .001], ablation time (WMD: -21.25; 95% CI: -25.36 to -17.13, P < .001), and fluoroscopy time (WMD: -4.13; 95% CI: -7.52 to -0.74, P < .001). Moreover, major complications and esophageal thermal injury (ETI) were similar between two groups (RR: 0.75; 95% CI: 0.44-1.30, P = .31) and (RR: 0.64; 95% CI: 0.17-2.39, P = .51). Conclusion HPSD was safe and efficient for treating AF with clear advantages of procedural features, it also showed benefits of higher first-pass PVI and reducing recurrence of atrial arrhythmias compared with the LPLD. Moreover, major complications and ETI were similar between two groups.
引用
收藏
页数:9
相关论文
共 39 条
[31]   Meta-analysis of observational studies in epidemiology - A proposal for reporting [J].
Stroup, DF ;
Berlin, JA ;
Morton, SC ;
Olkin, I ;
Williamson, GD ;
Rennie, D ;
Moher, D ;
Becker, BJ ;
Sipe, TA ;
Thacker, SB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (15) :2008-2012
[32]   Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial Fibrillation A Pilot Study [J].
Taghji, Philippe ;
El Haddad, Milad ;
Phlips, Thomas ;
Wolf, Michael ;
Knecht, Sebastien ;
Vandekerckhove, Yves ;
Tavernier, Rene ;
Nakagawa, Hiroshi ;
Duytschaever, Mattias .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (01) :99-108
[33]   Feasibility, Safety, and Efficacy of Posterior Wall Isolation During Atrial Fibrillation Ablation A Systematic Review and Meta-Analysis [J].
Thiyagarajah, Anand ;
Kadhim, Kadhim ;
Lau, Dennis H. ;
Emami, Mehrdad ;
Linz, Dominik ;
Khokhar, Kashif ;
Munawar, Dian A. ;
Mishima, Ricardo ;
Malik, Varun ;
O'Shea, Catherine ;
Mahajan, Rajiv ;
Sanders, Prashanthan .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (08)
[34]   Comparison of high-power short-duration (HPSD) ablation of atrial fibrillation using a contact force-sensing catheter and conventional technique: Initial results [J].
Vassallo, Fabricio ;
Cunha, Christiano ;
Serpa, Eduardo ;
Meigre, Lucas Luis ;
Carloni, Hermes ;
Simoes, Aloyr, Jr. ;
Hespanhol, Dalton ;
Lovatto, Carlos Volponi ;
Batista, Walter, Jr. ;
Serpa, Renato .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (10) :1877-1883
[35]   Low complication rates using high power (45-50 W) for short duration for atrial fibrillation ablations [J].
Winkle, Roger A. ;
Mohanty, Sanghamitra ;
Patrawala, Rob A. ;
Mead, R. Hardwin ;
Kong, Melissa H. ;
Engel, Gregory ;
Salcedo, Jonathan ;
Trivedi, Chintan G. ;
Gianni, Carola ;
Jais, Pierre ;
Natale, Andrea ;
Day, John D. .
HEART RHYTHM, 2019, 16 (02) :165-169
[36]   Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters [J].
Winkle, Roger A. ;
Moskovitz, Ryan ;
Mead, R. Hardwin ;
Engel, Gregory ;
Kong, Melissa H. ;
Fleming, William ;
Salcedo, Jonathan ;
Patrawala, Rob A. ;
Tranter, John H. ;
Shai, Isaac .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 52 (01) :1-8
[37]   Atrial Fibrillation Ablation: "Perpetual Motion" of Open Irrigated Tip Catheters at 50 W Is Safe and Improves Outcomes [J].
Winkle, Roger A. ;
Mead, R. Hardwin ;
Engel, Gregory ;
Patrawala, Rob A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (05) :531-539
[38]   Endoscopic evaluation of the esophagus after catheter ablation of atrial fibrillation using contiguous and optimized radiofrequency applications [J].
Wolf, Michael ;
El Haddad, Milad ;
De Wilde, Vincent ;
Phlips, Thomas ;
De Pooter, Jan ;
Almorad, Alexandre ;
Strisciuglio, Teresa ;
Vandekerckhove, Yves ;
Tavernier, Rene ;
Crijns, Harry J. ;
Knecht, Sebastien ;
Duytschaever, Mattias .
HEART RHYTHM, 2019, 16 (07) :1013-1020
[39]   Impedance drop predicts acute electrical reconnection of the pulmonary vein-left atrium after pulmonary vein isolation using short-duration high-power exposure [J].
Yazaki, Kyoichiro ;
Ejima, Koichiro ;
Kanai, Miwa ;
Kataoka, Shohei ;
Higuchi, Satoshi ;
Yagishita, Daigo ;
Shoda, Morio ;
Hagiwara, Nobuhisa .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 59 (03) :575-584