Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique

被引:12
|
作者
Kim, Jun-Hwee [1 ,2 ]
Kim, Myung-Joon [1 ,2 ]
Kim, Ha Yan [3 ]
Lee, Mi-Jung [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Severance Childrens Hosp, Dept Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Childrens Hosp, Res Inst Radiol Sci, Seoul 120752, South Korea
[3] Yonsei Univ, Severance Hosp, Biostat Collaborat Unit, Seoul 120752, South Korea
关键词
Pediatric; Computed tomography; Radiation dose; Iterative reconstruction; COMPUTED-TOMOGRAPHY; CARDIAC CT; CHEST CT; ANGIOGRAPHY; EXPOSURE; CHILDREN; SAFIRE; NOISE; ASIR;
D O I
10.1016/j.clinimag.2014.05.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to compare the radiation dose and image quality of pediatric abdominal computed tomography (CT) using a protocol reconstructed with filtered back projection (FBP) and a protocol with both kVp and mAs modulation and sinogram-affirmed iterative reconstruction (SAFIRE). Materials and methods: We retrospectively reviewed pediatric abdominal CT examinations performed with both kVp and mAs modulation. These raw data were reconstructed with SAFIRE at different strengths from 2 to 4 (SAFIRE groups 2-4). Another set of age/sex-matched pediatric abdominal CT examinations were also reviewed, which were performed during the same period with only mAs modulation and FBP (control group). The radiation dose and image quality were compared between groups. The image quality was objectively evaluated as the noise measured in the liver, aorta, and spleen at the level of the main portal vein and the image quality was subjectively reviewed by two radiologists for diagnostic acceptability using a four-point scale (0: unacceptable; 1: worse than the control group, but acceptable; 2: comparable with the control group; and 3: better than the control group). An independent t test was used in order to compare the radiation dose. An independent t test with Bonferroni correction and generalized estimating equations were used for the comparison of the objective and subjective image quality, respectively. Results: Twenty-nine patients (M:F=19:10; mean age, 10.0 years) were enrolled in each group. The SAFIRE group, using the size-specific dose estimates calculation method showed a 64.2% radiation dose reduction (from 8.1 to 2.9 mGy, P<.05), compared with the results of the control group. The objective image noise of the SAFIRE groups 2 and 3 was comparable to that of the control group. The subjective image quality was the best in SAFIRE group 3 [odds ratio (OR) 3.015, P<.001 when comparing to SAFIRE group 0; OR 1.513, P<.001 when comparing to SAFIRE group 2]. Conclusions: Image acquisition with both kVp and mAs modulation and iterative reconstruction using SAFIRE with strength 3 can preserve the objective and subjective image quality of pediatric abdominal CT scans with less than half the radiation dose. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:710 / 714
页数:5
相关论文
共 50 条
  • [21] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Tricarico, Francesco
    Hlavacek, Anthony M.
    Schoepf, U. Joseph
    Ebersberger, Ullrich
    Nance, John W., Jr.
    Vliegenthart, Rozemarijn
    Cho, Young Jun
    Spears, J. Reid
    Secchi, Francesco
    Savino, Giancarlo
    Marano, Riccardo
    Schoenberg, Stefan O.
    Bonomo, Lorenzo
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1306 - 1315
  • [22] Ultra-Low-Dose CT of the Thorax Using Iterative Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
    Kim, Yookyung
    Kim, Yoon Kyung
    Lee, Bo Eun
    Lee, Seok Jeong
    Ryu, Yon Ju
    Lee, Jin Hwa
    Chang, Jung Hyun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) : 1197 - 1202
  • [23] Reducing the radiation dose of pediatric paranasal sinus CT using an ultralow tube voltage (70 kVp) combined with iterative reconstruction Feasibility and image quality
    Chi, Jing
    Xu, Dongfeng
    Yin, Shengnan
    Li, Man
    Shen, Li
    Ding, Ning
    Chen, Xiaofang
    Ji, Yiding
    MEDICINE, 2020, 99 (34) : E21886
  • [24] Reducing CT radiation dose with iterative reconstruction algorithms: The influence of scan and reconstruction parameters on image quality and CTDIvol
    Klink, Thorsten
    Obmann, Verena
    Heverhagen, Johannes
    Stork, Alexander
    Adam, Gerhard
    Begemann, Philipp
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) : 1645 - 1654
  • [25] Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality
    Nagayama, Yasunori
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Yuki, Hideaki
    Hirarta, Kenichiro
    Oda, Seitaro
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Yamashita, Yasuyuki
    NEURORADIOLOGY, 2017, 59 (02) : 127 - 134
  • [26] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Bharti Kataria
    Jonas Nilsson Althén
    Örjan Smedby
    Anders Persson
    Hannibal Sökjer
    Michael Sandborg
    European Radiology, 2018, 28 : 2464 - 2473
  • [27] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Kataria, Bharti
    Althen, Jonas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokjer, Hannibal
    Sandborg, Michael
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2464 - 2473
  • [28] Objective assessment of image quality and dose reduction in CT iterative reconstruction
    Vaishnav, J. Y.
    Jung, W. C.
    Popescu, L. M.
    Zeng, R.
    Myers, K. J.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [29] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Yang, Lin
    Zhuang, Jian
    Huang, Meiping
    Liang, Changhong
    Liu, Hui
    PEDIATRIC RADIOLOGY, 2017, 47 (01) : 31 - 38
  • [30] Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom
    Ryu, Young Jin
    Choi, Young Hun
    Cheon, Jung-Eun
    Ha, Seongmin
    Kim, Woo Sun
    Kim, In-One
    PEDIATRIC RADIOLOGY, 2016, 46 (03) : 303 - 315