Drift correction in multivariate calibration models using on-line reference measurements

被引:9
作者
Gujral, Paman [1 ]
Amrhein, Michael [1 ]
Bonvin, Dominique [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Automat, CH-1015 Lausanne, Switzerland
关键词
Spectral measurements; Multivariate calibration; Drift invariance; Orthogonal projection; Space inclusion; DYNAMIC ORTHOGONAL PROJECTION; LEAST-SQUARES REGRESSION; NEAR-INFRARED SPECTRA; SPECTROSCOPIC DATA; ADAPTIVE-CONTROL; ENSEMBLE METHODS; PREDICTION; PLS; AUGMENTATION; ROBUSTNESS;
D O I
10.1016/j.aca.2008.12.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line measurements from first-order instruments such as spectrometers may be compromised by instrumental. process and operational drifts that are not seen during off-line calibration. This can render the calibration model unsuitable for prediction of key components such as analyte concentrations. In this work. infrequently available on-line reference measurements of the analytes of interest are used for drift correction. The drift-correction methods that include drift in the calibration set are referred to as implicit correction methods (ICM), while explicit correction methods (ECM) model the drift based on the reference measurements and make the calibration model orthogonal or invariant to the space spanned by the drift. Under some working assumptions such as linearity between the concentrations and the spectra, necessary and sufficient conditions for correct prediction using ICM and ECM are proposed. These so-called space-inclusion conditions can be checked on-line by monitoring the Q-statistic. Hence, violation of these conditions implies the violation of one or more of the working assumptions which can be used,, e.g. to infer the need for new reference measurements. These conditions are also valid for rank-deficient calibration data, i.e. when the concentrations of the various species are linearly dependent. A constraint on the kernel used in ECM follows from the space-inclusion condition. This kernel does not estimate the drift itself but leads to an unbiased estimate of the drift space. In a noise-free environment, it is shown that ICM and ECM are equivalent. However, in the presence of noise, a Monte Carlo simulation shows that ECM performs slightly better than ICM. A paired t-test indicates that this difference is statistically significant. When applied to experimental fermentation data, ICM and ECM lead to a significant reduction in prediction error for the concentrations of five metabolites predicted from infrared spectra. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 30 条
[1]   Calibration of spectral reaction data [J].
Amrhein, M ;
Srinivasan, B ;
Bonvin, D ;
Schumacher, MM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :249-264
[2]   On the rank deficiency and rank augmentation of the spectral measurement matrix [J].
Amrhein, M ;
Srinivasan, B ;
Bonvin, D ;
Schumacher, MM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 33 (01) :17-33
[3]   MEASUREMENT OF STRAY LIGHT IN ATOMIC-ABSORPTION SPECTROMETRY [J].
BLACK, SS ;
ROBARGE, WP ;
BOSS, CB .
APPLIED SPECTROSCOPY, 1990, 44 (02) :280-285
[4]   Multilevel multifactor designs for multivariate calibration [J].
Brereton, RG .
ANALYST, 1997, 122 (12) :1521-1529
[5]   On-line recalibration of spectral measurements using metabolite injections and dynamic orthogonal projection [J].
Dabros, Michal ;
Amrhein, Michael ;
Gujral, Paman ;
von Stockar, Urs .
APPLIED SPECTROSCOPY, 2007, 61 (05) :507-513
[6]   Recursive exponentially weighted PLS and its applications to adaptive control and prediction [J].
Dayal, BS ;
MacGregor, JF .
JOURNAL OF PROCESS CONTROL, 1997, 7 (03) :169-179
[7]   Optimization of partial-least-squares calibration models by simulation of instrumental perturbations [J].
Despagne, F ;
Massart, DL ;
deNoord, OE .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3391-3399
[8]   A comparison of multivariate calibration techniques applied to experimental NIR data sets - Part III: Robustness against instrumental perturbation conditions [J].
Estienne, F ;
Despagne, F ;
Walczak, B ;
de Noord, OE ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 73 (02) :207-218
[9]   Within-batch and batch-to-batch inferential-adaptive control of semibatch reactors: A partial least squares approach [J].
Flores-Cerrillo, J ;
MacGregor, JF .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2003, 42 (14) :3334-3345
[10]  
GALLAGHER NB, 1997, INT S ADV CONTR CHEM, P78