Intraoperative Conebeam CT for Assessment of Intracochlear Positioning of Electrode Arrays in Adult Recipients of Cochlear Implants

被引:24
作者
Jia, H. [1 ,2 ,3 ,4 ]
Torres, R. [1 ]
Nguyen, Y. [1 ,2 ]
De Seta, D. [1 ,2 ]
Ferrary, E. [1 ,2 ]
Wu, H. [3 ]
Sterkers, O. [1 ,2 ]
Bernardeschi, D. [1 ,2 ]
Mosnier, I. [1 ,2 ]
机构
[1] Univ Pierre & Marie Curie Paris 6, Sorbonne Univ, INSERM, Unite Rehabil Chirurg Mini Invas Robotisee Audit, Paris, France
[2] GHU Pitie Salpetriere, Serv ORL, Paris Assistance Publ, Otol,Implants Auditifs & Chirurg Base Crane, Paris, France
[3] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Otolaryngol Head & Neck Surg, Shanghai, Peoples R China
[4] Jiaotong Univ, Sch Med, Shanghai Key Lab Translat Med Ear & Nose Dis, Shanghai, Peoples R China
关键词
BEAM COMPUTED-TOMOGRAPHY; SCALAR LOCALIZATION; TEMPORAL BONES; STRAIGHT; COMPLICATIONS; MISPLACEMENT; MANAGEMENT; CARRIERS; QUALITY; HEAD;
D O I
10.3174/ajnr.A5567
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Intraoperative conebeam CT has been introduced into the operating room and provides quick radiologic feedback. This study aimed to investigate its utility in the assessment of the positioning of the electrode array after cochlear implantation. MATERIALS AND METHODS: This was a retrospective study of 51 patients (65 ears) with intraoperative imaging by conebeam CT (O-arm) after cochlear implantation between 2013 and 2017. Correct placement into the cochlea was immediately identified. Positioning assessments were later analyzed with OsiriX software. RESULTS: Intraoperative imaging was quickly performed in all cases. No misplacement into the vestibule or semicircular canals was found. A foldover of the implanted array was identified in 1 patient. Secondary analysis by 2 raters showed excellent agreement on insertion depth angle (intraclass correlation = 0.96, P < .001) and length of insertion of the electrode array (intraclass correlation coefficient = 0.93, P = .04) measurements. The evaluation of the number of extracochlear electrodes was identical between the 2 raters in 78% of cases (Cohen kappa = 0.55, P < .001). The scalar position was inconsistent between raters. When we compared O-arm and high-resolution CT images in 14 cases, the agreement was excellent for insertion depth angle (intraclass correlation coefficient = 0.97, P < .001) and insertion length (intraclass correlation coefficient = 0.98, P < .001), good for the number of extracochlear electrodes (Cohen kappa = 0.63, P = .01), but moderate for the scalar position (Cohen kappa = 0.59, P = .02). CONCLUSIONS: Intraoperative conebeam CT using the O-arm is a safe, rapid, easy, and reliable procedure to immediately identify a misplacement or foldover of an electrode array. The insertion depth angle, insertion length, and number of electrodes inserted can be accurately assessed.
引用
收藏
页码:768 / 774
页数:7
相关论文
共 33 条
[1]  
[Anonymous], 2012, ISRN OTOLARYNGOLOGY
[2]   Quality control after cochlear implant surgery by means of rotational tomography [J].
Aschendorff, A ;
Kubalek, T ;
Turowski, B ;
Zanella, T ;
Hochmuth, T ;
Schumacher, T ;
Klenzner, T ;
Laszig, R .
OTOLOGY & NEUROTOLOGY, 2005, 26 (01) :34-37
[3]   Spiral ganglion cells and macrophages initiate neuro-inflammation and scarring following cochlear implantation [J].
Bas, Esperanza ;
Goncalves, Stefania ;
Adams, Michelle ;
Dinh, Christine T. ;
Bas, Jose M. ;
Van De Water, Thomas R. ;
Eshraghi, Adrien A. .
FRONTIERS IN CELLULAR NEUROSCIENCE, 2015, 9
[4]   Scalar Localization by Cone-Beam Computed Tomography of Cochlear Implant Carriers: A Comparative Study Between Straight and Periomodiolar Precurved Electrode Arrays [J].
Boyer, Eric ;
Karkas, Alexandre ;
Attye, Arnaud ;
Lefournier, Virginie ;
Escude, Bernard ;
Schmerber, Sebastien .
OTOLOGY & NEUROTOLOGY, 2015, 36 (03) :422-429
[5]   Intraoperative Neural Response Telemetry as a Predictor of Performance [J].
Cosetti, Maura K. ;
Shapiro, William H. ;
Green, Janet E. ;
Roman, Benjamin R. ;
Lalwani, Anil K. ;
Gunn, Stacey H. ;
Roland, John Thomas, Jr. ;
Waltzman, Susan B. .
OTOLOGY & NEUROTOLOGY, 2010, 31 (07) :1095-1099
[6]   Morphologic examination of the temporal bone by cone beam computed tomography: Comparison with multislice helical computed tomography [J].
Dahmani-Causse, M. ;
Marx, M. ;
Deguine, O. ;
Fraysse, B. ;
Lepage, B. ;
Escude, B. .
EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2011, 128 (05) :230-235
[7]   3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study [J].
De Seta, D. ;
Mancini, P. ;
Russo, F. Y. ;
Torres, R. ;
Mosnier, I. ;
Bensimon, J. L. ;
De Seta, E. ;
Heymann, D. ;
Sterkers, O. ;
Bernardeschi, D. ;
Nguyen, Y. .
ACTA OTORHINOLARYNGOLOGICA ITALICA, 2016, 36 (06) :499-505
[8]   Analysis of Intraoperative Radiographic Electrode Placement During Cochlear Implantation [J].
Gnagi, Sharon H. ;
Baker, Trenton R. ;
Pollei, Taylor R. ;
Barrs, David M. .
OTOLOGY & NEUROTOLOGY, 2015, 36 (06) :1045-1047
[9]   Intra-operative skull X-ray for misdirection of the cochlear implant array into the vestibular labyrinth [J].
Hassan, A. M. ;
Patel, R. ;
Redleaf, M. .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2015, 129 (09) :923-927
[10]   Scalar Localization by Computed Tomography of Cochlear Implant Electrode Carriers Designed for Deep Insertion [J].
Helbig, Silke ;
Mack, Martin ;
Schell, Boris ;
Bratzke, Hansjuergen ;
Stoever, Timo ;
Helbig, Matthias .
OTOLOGY & NEUROTOLOGY, 2012, 33 (05) :745-750