Real-time trace gas sensing of fluorocarbons using a swept-wavelength external cavity quantum cascade laser

被引:50
作者
Phillips, Mark C. [1 ]
Taubman, Matthew S. [1 ]
Bernacki, Bruce E. [1 ]
Cannon, Bret D. [1 ]
Stahl, Robert D. [1 ]
Schiffern, John T. [1 ]
Myers, Tanya L. [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
LEAST-SQUARES METHODS; PHOTOACOUSTIC-SPECTROSCOPY; SINGLE-MODE; MU-M;
D O I
10.1039/c3an01642k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present results demonstrating real-time sensing of four different fluorocarbons at low part-per billion (ppb) concentrations using an external cavity quantum cascade laser (ECQCL) designed for infrared vibrational spectroscopy of molecules with broad absorption features. The ECQCL was repeatedly swept at 20 Hz over its full tuning range of 1145-1265 cm(-1) providing a scan rate of 3535 cm(-1) s(-1), and a detailed characterization of the ECQCL scan stability and repeatability is presented. The ECQCL was combined with a 100 meter path length multi-pass cell for direct absorption spectroscopy. A portable sensor system is described, which was deployed on a mobile automotive platform to provide spatially-resolved detection of fluorocarbons in outdoor experiments. Noise-equivalent detection limits of 8001000 parts-per-trillion (ppt) are demonstrated for 1 s integration times.
引用
收藏
页码:2047 / 2056
页数:10
相关论文
共 44 条
[1]   An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[2]   Direct determination of glucose, lactate and triglycerides in blood serum by a tunable quantum cascade laser-based mid-IR sensor [J].
Brandstetter, M. ;
Volgger, L. ;
Genner, A. ;
Jungbauer, C. ;
Lendl, B. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2013, 110 (02) :233-239
[3]   Tunable external cavity quantum cascade laser for the simultaneous determination of glucose and lactate in aqueous phase [J].
Brandstetter, Markus ;
Genner, Andreas ;
Anic, Kresimir ;
Lendl, Bernhard .
ANALYST, 2010, 135 (12) :3260-3265
[4]   Single-mode, narrow-linewidth external cavity quantum cascade laser through optical feedback from a partial-reflector [J].
Cendejas, Richard A. ;
Phillips, Mark C. ;
Myers, Tanya L. ;
Taubman, Matthew S. .
OPTICS EXPRESS, 2010, 18 (25) :26037-26045
[5]   Quantum cascade lasers in chemical physics [J].
Curl, Robert F. ;
Capasso, Federico ;
Gmachl, Claire ;
Kosterev, Anatoliy A. ;
McManus, Barry ;
Lewicki, Rafal ;
Pusharsky, Michael ;
Wysocki, Gerard ;
Tittel, Frank K. .
CHEMICAL PHYSICS LETTERS, 2010, 487 (1-3) :1-18
[6]   Ultra-sensitive carbon monoxide detection by using EC-QCL based quartz-enhanced photoacoustic spectroscopy [J].
Dong, L. ;
Lewicki, R. ;
Liu, K. ;
Buerki, P. R. ;
Weida, M. J. ;
Tittel, F. K. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 107 (02) :275-283
[7]   QUANTUM CASCADE LASER [J].
FAIST, J ;
CAPASSO, F ;
SIVCO, DL ;
SIRTORI, C ;
HUTCHINSON, AL ;
CHO, AY .
SCIENCE, 1994, 264 (5158) :553-556
[8]   Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide [J].
Foltynowicz, A. ;
Maslowski, P. ;
Fleisher, A. J. ;
Bjork, B. J. ;
Ye, J. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2013, 110 (02) :163-175
[9]   Imaging standoff detection of explosives using widely tunable midinfrared quantum cascade lasers [J].
Fuchs, Frank ;
Hugger, Stefan ;
Kinzer, Michel ;
Aidam, Rolf ;
Bronner, Wolfgang ;
Loesch, Rainer ;
Yang, Quankui ;
Degreif, Kai ;
Schnuerer, Frank .
OPTICAL ENGINEERING, 2010, 49 (11)
[10]   Stand-off detection of trace explosives via resonant infrared photothermal imaging [J].
Furstenberg, R. ;
Kendziora, C. A. ;
Stepnowski, J. ;
Stepnowski, S. V. ;
Rake, M. ;
Papantonakis, M. R. ;
Nguyen, V. ;
Hubler, G. K. ;
McGill, R. A. .
APPLIED PHYSICS LETTERS, 2008, 93 (22)