Evaluation of radiotherapy setup accuracy for head and neck cancer using a 3-D surface imaging system

被引:9
作者
Cho, H. -L. [1 ]
Park, E. -T. [1 ]
Kim, J. -Y. [2 ]
Kwak, K. -S. [1 ]
Kim, C. -J. [1 ]
Ahn, K. -J. [1 ]
Suh, T. -S. [3 ]
Lee, Y. -K. [4 ]
Kim, S. -W. [5 ]
Kim, J. -K. [6 ]
Lim, S. [8 ]
Choi, Y. -M. [7 ]
Park, S. -K. [1 ]
机构
[1] Inje Univ, Busan Paik Hosp, Pusan, South Korea
[2] Inje Univ, Haeundae Paik Hosp, Pusan, South Korea
[3] Catholic Univ, Seoul, South Korea
[4] Inje Univ, Gimhae, Gyeongnam, South Korea
[5] Catholic Univ, Incheon St Marys Hosp, Inchon, South Korea
[6] Dongnam Inst Radiolo Med Sci, Pusan, South Korea
[7] Dong A Univ, Dong A Univ Hosp, Pusan, South Korea
[8] Kosin Univ, Kosin Univ Hosp, Pusan, South Korea
关键词
Radiotherapy concepts; Portal imaging; X-ray radiography and digital radiography (DR); PATIENT SETUP; PHANTOM EVALUATION; TUMORS; IRRADIATION; BRAIN;
D O I
10.1088/1748-0221/8/11/T11002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of this study was to measure the accuracy of a three-dimensional surface imaging system (3-D SIS) in comparison to a 3-laser system by analyzing the setup errors obtained from a RANDO Phantom and head and neck cancer patients. The 3-D SIS used for the evaluation of the setup errors was a C-RAD Sentinel. In the phantom study, the OBI setup errors without the thermoplastic mask of the 3-laser system vs. the 3-D SIS were measured. Furthermore, the setup errors with the thermoplastic mask of the 3-laser system vs. the 3-D SIS were measured. After comparison of the CBCT, setup correction about 1mm was performed in a few cases. The probability of the error without the thermoplastic mask exceeding 1mm in the 3-laser system vs. the 3-D SIS was 75.00% vs. 35.00% on the X-axis, 80.00% vs. 40.00% on the Y-axis, and 80.00% vs. 65.00% on the Z-axis. Moreover, the probability of the error with the thermoplastic mask exceeding 1mm in the 3-laser system vs. the 3-D SIS was 70.00% vs. 15.00% on the X-axis, 75.00% vs. 25.00% on the Y-axis, and 70.00% vs. 35.00% on the Z-axis. These results showed that the 3-D SIS has a lower probability of setup error than the 3-laser system for the phantom. For the patients, the setup errors of the 3-laser system vs. the 3-D SIS were measured. The probability of the error exceeding more than 1mm in the 3-laser system vs. the 3-D SIS was shown to be 81.82% vs. 36.36% on the X-axis, 81.82% vs. 45.45% on the Y-axis, and 86.36% vs. 72.73% on the Z-axis. As a result, the 3-D SIS also exhibited a lower probability of setup error for the cancer patients. Therefore, this study confirmed that the 3-D SIS is a promising method for setup verification.
引用
收藏
页数:13
相关论文
共 22 条
[1]   Specification of dose delivery in radiation therapy - Recommendations by the Nordic Association of Clinical Physics (NACP) [J].
Aaltonen, P ;
Brahme, A ;
Lax, I ;
Levernes, S ;
Naslund, I ;
Reitan, JB ;
Turesson, I .
ACTA ONCOLOGICA, 1997, 36 :1-32
[2]   Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients [J].
Bert, C ;
Metheany, KG ;
Doppke, KP ;
Taghian, AG ;
Powell, SN ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04) :1265-1274
[3]   A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup [J].
Bert, C ;
Metheany, KG ;
Doppke, K ;
Chen, GTY .
MEDICAL PHYSICS, 2005, 32 (09) :2753-2762
[4]   4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures [J].
Brahme, Anders ;
Nyman, Peter ;
Skatt, Bjoern .
MEDICAL PHYSICS, 2008, 35 (05) :1670-1681
[5]   Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study [J].
Cervino, Laura I. ;
Pawlicki, Todd ;
Lawson, Joshua D. ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :1863-1873
[6]   Determination and delineation of nodal target volumes for head-and-neck cancer based on patterns of failure in patients receiving definitive and postoperative IMRT [J].
Chao, KSC ;
Wippold, FJ ;
Ozyigit, G ;
Tran, BN ;
Dempsey, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1174-1184
[7]   Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors [J].
Gilbeau, L ;
Octave-Prignot, M ;
Loncol, T ;
Renard, L ;
Scalliet, P ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :155-162
[8]   Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy [J].
Gopan, Olga ;
Wu, Qiuwen .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02) :547-552
[9]  
Hurmans C.W., 2001, RADIOTHER ONCOL, V58, P105
[10]   Three-dimensional accuracy and interfractional reproducibility of patient fixation and positioning using a stereotactic head mask system [J].
Karger, CP ;
Jäkel, O ;
Debus, J ;
Kuhn, S ;
Hartmann, GH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05) :1493-1504