Marginal adaptation of three-unit fixed partial dentures constructed from pressed ceramic systems

被引:28
作者
Stappert, CFJ
Dai, M
Chitmongkolsuk, S
Gerds, T
Strub, JR
机构
[1] Univ Freiburg, Fac Dent, Dept Prosthodont, D-79106 Freiburg, Germany
[2] Univ Freiburg, Inst Med Biometr & Med Informat, Freiburg, Germany
[3] Mahidol Univ, Fac Dent, Dept Prosthodont, Bangkok 10700, Thailand
关键词
D O I
10.1038/sj.bdj.4811390
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose This study compares the marginal accuracy of posterior metal ceramic (MC), all-ceramic IPS Empress(R) 2 and experimental pressed ceramic (EPC-VP 1989/4) three-unit fixed partial dentures (FPD), before and after luting and after thermo-mechanical fatigue in a dual-axis chewing simulator. Materials and methods Caries-free human teeth (n=160) were used as abutments for the fabrication of eighty posterior three-unit FPD, divided into two test-groups, IPS Empress(R) 2 and EPC, of 32 samples each and one control group of 16 samples metal ceramic FPD. All FPD were cemented with Variolink(R) II dual-curing resin cement. Half of the samples in each group were exposed to a dual-axis chewing simulator. Results The geometric mean marginal gap values (mum, before cementation, after cementation and after thermo-mechanical fatigue) amounted to 53, 63 and 62 for the ceramic metal FPD, 57, 71 and 68 for the Empress(R) 2 FPD and 55, 67 and 68 for the EPC FPD. In all groups a statistically significant increase in marginal gap width was observed after cementation. The effect of functional loading in the chewing simulator on marginal gap was not significant. Marginal gap was lowest in the control group but differences with all-ceramic materials were small in all evaluation stages. Conclusion Within the limits of this investigation, it can be concluded that marginal gap values of these all-ceramic materials and conventional MC techniques are on a similar level. In particular, almost all marginal gap values observed in this study were within the limits of clinical acceptance.
引用
收藏
页码:766 / 770
页数:5
相关论文
共 50 条
[1]  
Alkumru H N, 1992, J Marmara Univ Dent Fac, V1, P198
[2]   A NEW ALL-CERAMIC CROWN - A DENSE-SINTERED, HIGH-PURITY ALUMINA COPING WITH PORCELAIN [J].
ANDERSSON, M ;
ODEN, A .
ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (01) :59-64
[3]  
Bates J F, 1976, J Oral Rehabil, V3, P57, DOI 10.1111/j.1365-2842.1976.tb00929.x
[4]   CONFIRMATION OF LEINFELDER CLINICAL WEAR STANDARDS [J].
BAYNE, SC ;
TAYLOR, DF ;
REKOW, ED ;
WILDER, AD ;
HEYMANN, HO .
DENTAL MATERIALS, 1994, 10 (01) :11-18
[5]   FIT OF 3 PORCELAIN-FUSED-TO-METAL MARGINAL DESIGNS INVIVO - A SCANNING ELECTRON-MICROSCOPE STUDY [J].
BELSER, UC ;
MACENTEE, MI ;
RICHTER, WA .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (01) :24-29
[6]   Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth [J].
Beschnidt, SM ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (07) :582-593
[7]  
Bieniek K W, 1994, Schweiz Monatsschr Zahnmed, V104, P284
[8]   Clinical fit of Procera AllCeram crowns [J].
Boening, KW ;
Wolf, BH ;
Schmidt, AE ;
Kästner, K ;
Walter, MH .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) :419-424
[9]  
Buchalla W, 2000, OPER DENT, V25, P482
[10]  
Burke FJT, 1998, QUINTESSENCE INT, V29, P103