Quantitative performance of 124I PET/MR of neck lesions in thyroid cancer patients using 124I PET/CT as reference

被引:9
作者
Jentzen, Walter [1 ]
Phaosricharoen, Jinda [1 ]
Gomez, Benedikt [1 ]
Hetkamp, Philipp [1 ]
Stebner, Vanessa [1 ]
Binse, Ina [1 ]
Kinner, Sonja [3 ]
Herrmann, Ken [1 ]
Sabet, Amir [4 ]
Nagarajah, James [1 ,2 ]
机构
[1] Univ Duisburg Essen, Dept Nucl Med, Hufelandstr 55, D-45122 Essen, Germany
[2] Radboudumc, Dept Radiol & Nucl Med, Nijmegen, Netherlands
[3] Univ Duisburg Essen, Dept Radiol, Essen, Germany
[4] Univ Hosp Frankfurt, Dept Nucl Med, Frankfurt, Germany
关键词
PET/MR; PET/CT; Iodine-124; Differentiated thyroid cancer; ONCOLOGIC APPLICATIONS; RADIOIODINE TREATMENT; DOSIMETRY;
D O I
10.1186/s40658-018-0214-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In patients with differentiated thyroid cancer (DTC), serial I-124 PET/CT imaging is, for instance, used to assess the absorbed (radiation) dose to lesions. Frequently, the lesions are located in the neck and they are close to or surrounded by different tissue types. In contrast to PET/CT, MR-based attenuation correction in PET/MR may be therefore challenging in the neck region. The aim of this retrospective study was to assess the quantitative performance of I-124 PET/MRI of neck lesions by comparing the MR-based and CT-based I-124 activity concentrations (ACs). Sixteen DTC patients underwent PET/CT scans at 24 and 120 h after administration of about 25 MBq I-124. Approximately 1 h before or after PET/CT examination, each patient additionally received a 24-h PET/MR scan and sometimes a 120-h PET/MR scan. PET images were reconstructed using the respective attenuation correction approach. Appropriate reconstruction parameters and corrections were used to harmonize the reconstructed PET images to provide, for instance, similar spatial resolution. For each lesion, two types of ACs were ascertained: the maximum AC (max-AC) and an average AC (avg-AC). The avg-AC is the average activity concentration obtained within a spherical volume of interest with a diameter of 7 mm, equaling the PET scanner resolution. For each type of AC, the percentage AC difference between MR-based and CT-based ACs was determined and Lin's concordance correlation analysis was applied. Quantitative performance was considered acceptable if the standard deviation was +/- 25% (precision), and the mean value was within +/- 10% (accuracy). Results: The avg-ACs (max-ACs within parentheses) of 74 lesions ranged from 0.20 (0.33) to 657 (733) kBq/mL. Excluding two lesions with ACs of approximately 1 kBq/mL, the mean (median) +/- standard deviation (range) was -4% (-5%) +/- 14% (-28 to 29%) for the avg-AC and -9% (-11%) +/- 14% (-33 to 33%) for the max-AC. Lin's concordance correlation coefficients were >= 0.97, indicating substantial AC agreement. Conclusions: Quantification of lesions in the neck region using I-124 PET/MR showed acceptable quantitation performance to I-124 PET/CT for AC above 1 kBq/mL. The PET/MRI-based I-124 ACs in the neck region can be therefore reliably used in pre-therapy dosimetry planning.
引用
收藏
页数:13
相关论文
共 50 条
[31]   Impact of prompt gamma coincidence correction on absorbed dose estimation in differentiated thyroid cancer using 124I PET/CT imaging [J].
Wierts, Roel ;
Conti, Maurizio ;
Claessen, Anouk G. G. ;
Herrmann, Ken ;
Kemerink, Gerrit J. ;
Binse, Ina ;
Wildberger, Joachim E. ;
Mottaghy, Felix M. ;
Backes, Walter H. ;
Jentzen, Walter .
NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (12) :1156-1164
[32]   Effects of Rosiglitazone on Radioiodine Negative and Progressive Differentiated Thyroid Carcinoma as Assessed by 124I PET/CT Imaging [J].
Rosenbaum-Krumme, Sandra Julia ;
Freudenberg, Lutz Stefan ;
Jentzen, Walter ;
Bockisch, Andreas ;
Nagarajah, James .
CLINICAL NUCLEAR MEDICINE, 2012, 37 (03) :E47-E52
[33]   124I PET/CT to Predict the Outcome of Blind 131I Treatment in Patients with Biochemical Recurrence of Differentiated Thyroid Cancer: Results of a Multicenter Diagnostic Cohort Study (THYROPET) [J].
Kist, Jakob W. ;
de Keizer, Bart ;
van der Vlies, Manfred ;
Brouwers, Adrienne H. ;
Huysmans, Dyde A. ;
van der Zant, Friso M. ;
Hermsen, Rick ;
Stokkel, Marcel P. M. ;
Hoekstra, Otto S. ;
Vogel, Wouter V. .
JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (05) :701-707
[34]   The spectrum of 124I uptake in the lacrimal gland and nasolacrimal sac/duct on PET/CT imaging [J].
Wu, Di ;
Plyku, Donika ;
Kulkarni, Kanchan ;
Garcia, Carlos ;
Burman, Kenneth D. ;
Wartofsky, Leonard ;
Van Nostrand, Douglas .
NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (03) :292-299
[35]   Late 124I PET/CT Uptake Measurement-Assessment of Appropriate Examination Protocol in Benign Thyroid Diseases [J].
Freesmeyer, Martin ;
Gabler, Anja S. ;
Kuehnel, Christian ;
Winkens, Thomas .
CLINICAL NUCLEAR MEDICINE, 2017, 42 (07) :514-519
[36]   Patient-Specific Dosimetry Using Pretherapy [124I]m-iodobenzylguanidine ([124I]mIBG) Dynamic PET/CT Imaging Before [131I]mIBG Targeted Radionuclide Therapy for Neuroblastoma [J].
Huang, Shih-ying ;
Bolch, Wesley E. ;
Lee, Choonsik ;
Van Brocklin, Henry F. ;
Pampaloni, Miguel H. ;
Hawkins, Randall A. ;
Sznewajs, Aimee ;
DuBois, Steven G. ;
Matthay, Katherine K. ;
Seo, Youngho .
MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (02) :284-294
[37]   Patient-Specific Dosimetry Using Pretherapy [124I]m-iodobenzylguanidine ([124I]mIBG) Dynamic PET/CT Imaging Before [131I]mIBG Targeted Radionuclide Therapy for Neuroblastoma [J].
Shih-ying Huang ;
Wesley E. Bolch ;
Choonsik Lee ;
Henry F. Van Brocklin ;
Miguel H. Pampaloni ;
Randall A. Hawkins ;
Aimee Sznewajs ;
Steven G. DuBois ;
Katherine K. Matthay ;
Youngho Seo .
Molecular Imaging and Biology, 2015, 17 :284-294
[38]   Efficiency of 124I radioisotope production from natural and enriched tellurium dioxide using 124Te(p,xn)124I reaction [J].
Paweł Bzowski ;
Damian Borys ;
Kamil Gorczewski ;
Agnieszka Chmura ;
Kinga Daszewska ;
Izabela Gorczewska ;
Anna Kastelik-Hryniewiecka ;
Marcin Szydło ;
Andrea d’Amico ;
Maria Sokół .
EJNMMI Physics, 9
[39]   Efficiency of 124I radioisotope production from natural and enriched tellurium dioxide using 124Te(p,xn)124I reaction [J].
Bzowski, Pawel ;
Borys, Damian ;
Gorczewski, Kamil ;
Chmura, Agnieszka ;
Daszewska, Kinga ;
Gorczewska, Izabela ;
Kastelik-Hryniewiecka, Anna ;
Szydlo, Marcin ;
d'Amico, Andrea ;
Sokol, Maria .
EJNMMI PHYSICS, 2022, 9 (01)
[40]   Recombinant Human Thyroid-Stimulating Hormone Versus Thyroid Hormone Withdrawal in 124I PET/CT-Based Dosimetry for 131I Therapy of Metastatic Differentiated Thyroid Cancer [J].
Plyku, Donika ;
Hobbs, Robert F. ;
Huang, Kevin ;
Atkins, Frank ;
Garcia, Carlos ;
Sgouros, George ;
Van Nostrand, Douglas .
JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (07) :1146-1154