Myocardial contrast echocardiography: Reliable, safe, and efficacious myocardial perfusion assessment after intravenous injections of a new echocardiographic contrast agent

被引:50
作者
Meza, M
Greener, Y
Hunt, R
Perry, B
Revall, S
Barbee, W
Murgo, JP
Cheirif, J
机构
[1] OCHSNER MED INST,DEPT INTERNAL MED,CARDIOL SECT,NEW ORLEANS,LA
[2] MOL BIOSYST INC,DEPT PRECLIN STUDIES,SAN DIEGO,CA
关键词
D O I
10.1016/S0002-8703(96)90324-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reliable and reproducible myocardial opacification after intravenous administration of echocardiographic contrast agents has remained elusive. This study was performed to determine whether a new agent, FS069, a suspension of perfluoropropane-filled albumin microspheres (3.6 μm average microbubble size, concentration 8 x 88/ml), could achieve safe and successful myocardial opacification in open-chest dogs. Seventeen dogs (group 1, n = 7, group 2, n = 10) underwent two-dimensional echocardiography before, during, and after the administration of intravenous FS069. Safety was evaluated by measuring arterial and pulmonary artery pressures, heart rate, blood gases, systolic function, myocardial blood flow, and postmortem analysis of myocardial viability by triphenyl-tetrazolium chloride staining. Efficacy to detect changes in regional myocardial perfusion was assessed by injecting FS069 at baseline, after sequential coronary occlusions and reperfusion, and during intravenous vasodilators with and without coronary occlusions. Results were compared with radiolabeled microspheres. FS069 was found to be safe and effective. In the absence of coronary occlusions, uniform myocardial opacification was observed in all dogs. A perfusion defect was observed in all dogs during coronary occlusions. Background-subtracted peak contrast intensity in the myocardium correctly identified regional myocardial blood flow changes and showed a significant correlation with radiolabeled microspheres (r = 0.65, p = 0.0001).
引用
收藏
页码:871 / 881
页数:11
相关论文
共 35 条
  • [21] MEZA M, 1994, J AM SOC ECHOCARDIOG, V7, pS36
  • [22] MEZA MF, 1994, J AM SOC ECHOCARDIOG, V7, pS2
  • [23] MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY FOR THE ASSESSMENT OF CORONARY BLOOD-FLOW RESERVE - VALIDATION IN HUMANS
    PORTER, TR
    DSA, A
    TURNER, C
    JONES, LA
    MINISI, AJ
    MOHANTY, PK
    VETROVEC, GW
    NIXON, JV
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) : 349 - 355
  • [24] VISUALLY DISCERNIBLE MYOCARDIAL ECHOCARDIOGRAPHIC CONTRAST AFTER INTRAVENOUS-INJECTION OF SONICATED DEXTROSE ALBUMIN MICROBUBBLES CONTAINING HIGH-MOLECULAR-WEIGHT, LESS SOLUBLE GASES
    PORTER, TR
    XIE, F
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) : 509 - 515
  • [25] PERCENTAGE OF SHORTENING OF ECHOCARDIOGRAPHIC LEFT-VENTRICULAR DIMENSION - ITS USE IN DETERMINING EJECTION FRACTION AND STROKE VOLUME
    QUINONES, MA
    PICKERING, E
    ALEXANDER, JK
    [J]. CHEST, 1978, 74 (01) : 59 - 65
  • [26] FUNCTIONAL-SIGNIFICANCE OF COLLATERAL BLOOD-FLOW IN PATIENTS WITH RECENT ACUTE MYOCARDIAL-INFARCTION - A STUDY USING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY
    SABIA, PJ
    POWERS, ER
    JAYAWEERA, AR
    RAGOSTA, M
    KAUL, S
    [J]. CIRCULATION, 1992, 85 (06) : 2080 - 2089
  • [27] CONTRAST OPACIFICATION OF LEFT-VENTRICULAR MYOCARDIUM FOLLOWING INTRAVENOUS ADMINISTRATION OF SONICATED ALBUMIN MICROSPHERES
    SANDERS, WE
    CHEIRIF, J
    DESIR, R
    ZOGHBI, WA
    HOYT, BD
    SCHULZ, PE
    QUINONES, MA
    [J]. AMERICAN HEART JOURNAL, 1991, 122 (06) : 1660 - 1665
  • [28] LEFT HEART OPACIFICATION WITH PERIPHERAL VENOUS INJECTION OF A NEW SACCHARIDE ECHO CONTRAST AGENT IN DOGS
    SMITH, MD
    ELION, JL
    MCCLURE, RR
    KWAN, OL
    DEMARIA, AN
    EVANS, J
    FRITZSCH, TH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) : 1622 - 1628
  • [29] MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY DURING HYPEREMIA
    TENCATE, FJ
    SILVERMAN, PR
    CORNEL, JH
    SERRUYS, PW
    ROELANDT, JRTC
    [J]. CORONARY ARTERY DISEASE, 1990, 1 (05) : 573 - 578
  • [30] MYOCARDIAL CONTRAST TWO-DIMENSIONAL ECHOCARDIOGRAPHY - EXPERIMENTAL EXAMINATION AT DIFFERENT CORONARY FLOW LEVELS
    TENCATE, FJ
    DRURY, JK
    MEERBAUM, S
    NOORDSY, J
    FEINSTEIN, S
    SHAH, PM
    CORDAY, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (05) : 1219 - 1226