CONTROLLING GASEOUS AND PARTICULATE CONTAMINATION IN DATA CENTERS

被引:0
作者
Muller, C. [1 ]
Yao, W. L. [1 ]
Yu, Q. L. [1 ]
Hua, Y. [2 ]
Zhong, J. H. [3 ]
机构
[1] Purafil Inc, Doraville, GA 30340 USA
[2] IBM China Co Ltd, Beijing, Peoples R China
[3] China Elect Engn Design Inst, Beijing, Peoples R China
来源
7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV | 2011年
关键词
Data center; Contamination control; Corrosion; Air cleaning; Air monitoring;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Data centers operating in areas with high ambient pollution are experiencing corrosion-related hardware failures due to changes in electronic equipment brought about by recent "lead-free" regulations. Data centers located in areas with lower pollution levels may also experience similar problems especially when using air-side economizers for "free cooling." When monitoring indicates that air quality does not fall within specified corrosion limits, enhanced air cleaning is required. Combination gas-phase / particulate air filters may be used to remove outdoor contaminants as well as any internally-generated contaminants to maintain acceptable air quality within the data center. This paper will discuss basic design requirements for the optimum control of contamination in data centers and the application of enhanced-air cleaning. General aspects of air cleaning technology will be presented and where it may be used within the data center. Passive and real-time corrosion monitoring techniques used in data centers will be described. Air monitoring data will show that corrosive environments exist in locations that would otherwise be considered benign if not for the changes mandated by lead-free legislation. A case study will be presented showing the effectiveness of data center design modifications made in conjunction with the application of enhanced air cleaning.
引用
收藏
页码:920 / 927
页数:8
相关论文
共 50 条
  • [21] Workload Failure Prediction for Data Centers
    Li, Jie
    Wang, Rui
    Ali, Ghazanfar
    Dang, Tommy
    Sill, Alan
    Chen, Yong
    2023 IEEE 16TH INTERNATIONAL CONFERENCE ON CLOUD COMPUTING, CLOUD, 2023, : 479 - 485
  • [22] Optical wireless communication in data centers
    Arnon, Shlomi
    BROADBAND ACCESS COMMUNICATION TECHNOLOGIES XII, 2018, 10559
  • [23] MODEL OF HEAT SIMULATOR FOR DATA CENTERS
    Novotny, Jan
    Nozicka, Jiri
    ACTA POLYTECHNICA, 2016, 56 (04) : 301 - 305
  • [24] A review on airflow management in data centers
    Chu, Wen-Xiao
    Wang, Chi-Chuan
    APPLIED ENERGY, 2019, 240 : 84 - 119
  • [25] Estimating the environmental impact of Data Centers
    Ferreira, Joao
    Callou, Gustavo
    Josua, Albert
    Maciel, Paulo
    2018 IEEE 17TH INTERNATIONAL SYMPOSIUM ON NETWORK COMPUTING AND APPLICATIONS (NCA), 2018,
  • [26] NFV Data Centers: A Systematic Review
    Souza, Rafael
    Dias, Kelvin
    Fernandes, Stenio
    IEEE ACCESS, 2020, 8 : 51713 - 51735
  • [27] Prototype energy models for data centers
    Sun, Kaiyu
    Luo, Na
    Luo, Xuan
    Hong, Tianzhen
    ENERGY AND BUILDINGS, 2021, 231
  • [28] Smart Data Centers For Green Clouds
    Bruneo, Dario
    Fazio, Maria
    Longo, Francesco
    Puliafito, Antonio
    2013 IEEE SYMPOSIUM ON COMPUTERS AND COMMUNICATIONS (ISCC), 2013,
  • [29] Automated Synthesis of Sustainable Data Centers
    Christian, Tom
    Chen, Yuan
    Shih, Rocky
    Sharma, Ratnesh
    Hoover, Christopher
    Marwah, Manish
    Shah, Amip
    Gmach, Daniel
    2009 IEEE INTERNATIONAL SYMPOSIUM ON SUSTAINABLE SYSTEMS AND TECHNOLOGY, 2009, : 222 - 227
  • [30] Explicit Dropping Notification in Data Centers
    Meng, Qingkai
    Zhang, Yiran
    Hu, Chaolei
    Wang, Bo
    Ren, Fengyuan
    IEEE INFOCOM 2024-IEEE CONFERENCE ON COMPUTER COMMUNICATIONS, 2024, : 1391 - 1400