The Impact of Catheter Ablation in the Interpulmonary Isthmus on Atrial Fibrillation Ablation Outcomes: A Randomized Study

被引:2
作者
Letsas, Konstantinos P. [1 ]
Efremidis, Michael [1 ]
Vlachos, Konstantinos [1 ]
Karlis, Dimitrios [1 ]
Lioni, Louiza [1 ]
Asvestas, Dimitrios [1 ]
Valkanas, Kosmas [1 ]
Mihas, Constantinos C. [1 ]
Sideris, Antonios [1 ]
机构
[1] Evangelismos Gen Hosp Athens, Dept Cardiol 2, Lab Cardiac Electrophysiol, Athens 10676, Greece
关键词
atrial fibrillation; catheter ablation; electroanatomic mapping; interpulmonary isthmus; pulmonary vein isolation; PULMONARY VEIN ISOLATION; DOUBLE-LASSO TECHNIQUE; TRIGGERS; SITES;
D O I
10.1111/jce.12399
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Catheter Ablation in the Interpulmonary Isthmus. Introduction: Previous studies have underscored the importance of the interpulmonary isthmus in the initiation and maintenance of atrial fibrillation (AF). The efficacy of additional radiofrequency energy delivery in the interpulmonary isthmus following pulmonary vein antral isolation (PVAI) was investigated. Methods and Results: A total of 76 patients (49 males, mean age 56.8 +/- 10.3) with drug-resistant paroxysmal (n = 64) and short-lasting persistent AF (n = 12) underwent PVAI. Patients were then randomly assigned to receive either "no further ablation" (group I, n = 38) or additional lesions in the interpulmonary isthmus of both ipsilateral pulmonary veins (group II, n = 38). Therewere no significant differences between study groups regarding the clinical and echocardiographic data. A trend towards a longer fluoroscopy time was observed in group II (P = 0.076). After a mean follow-up period of 11.1 +/- 2.6 months, 22 patients in group I (57.9%) and 25 patients in group II (65.8%) were free from arrhythmia recurrence without any antiarrhythmic drug treatment after a single ablation procedure. The Kaplan-Meier arrhythmia-free survival curves showed no significant differences between study groups (P = 0.460). Conclusions: Additional lesions in the interpulmonary isthmus following PVAI do not have incremental value in preventing AF recurrence.
引用
收藏
页码:709 / 713
页数:5
相关论文
共 17 条
  • [1] Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? -: Results from a prospective randomized study
    Arentz, Thomas
    Weber, Reinhold
    Buerkle, Gerd
    Herrera, Claudia
    Blum, Thomas
    Stockinger, Jochem
    Minners, Jan
    Neumann, Franz Josef
    Kalusche, Dietrich
    [J]. CIRCULATION, 2007, 115 (24) : 3057 - 3063
  • [2] Morphological evidence of muscular connections between contiguous pulmonary venous orifices: Relevance of the interpulmonary isthmus for catheter ablation in atrial fibrillation
    Cabrera, Jose Angel
    Ho, Siew Yen
    Climent, Vicente
    Fuertes, Beatriz
    Murillo, Margarita
    Sanchez-Quintana, Damian
    [J]. HEART RHYTHM, 2009, 6 (08) : 1192 - 1198
  • [3] Camm AJ, 2010, EUROPACE, V12, P1360, DOI [10.1093/europace/euq350, 10.1093/eurheartj/ehq278]
  • [4] Incidence and location of focal atrial fibrillation triggers in patients undergoing repeat pulmonary vein isolation: Implications for ablation strategies
    Gerstenfeld, ER
    Callans, DJ
    Dixit, S
    Zado, E
    Marchlinski, FE
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (07) : 685 - 690
  • [5] Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Takahashi, A
    Hocini, M
    Quiniou, G
    Garrigue, S
    Le Mouroux, A
    Le Métayer, P
    Clémenty, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) : 659 - 666
  • [6] The Importance of Atrial Structure and Fibers
    Ho, S. Y.
    Sanchez-Quintana, D.
    [J]. CLINICAL ANATOMY, 2009, 22 (01) : 52 - 63
  • [7] Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: A prospective study
    Kistler, Peter M.
    Ho, Siew Yen
    Rajappan, Kim
    Morper, Michael
    Harris, Stuart
    Abrams, Dominic
    Sporton, Simon C.
    Schilling, Richard J.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (12) : 1282 - 1288
  • [8] The impact of body mass index on the efficacy and safety of catheter ablation of atrial fibrillation
    Letsas, Konstantinos P.
    Siklody, Claudia Herrera
    Korantzopoulos, Panagiotis
    Weber, Reinhold
    Buerkle, Gerd
    Mihas, Constantinos C.
    Kalusche, Dietrich
    Arentz, Thomas
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 164 (01) : 94 - 98
  • [9] Catheter ablation for atrial fibrillation
    O'Neill, Mark D.
    Jais, Pierre
    Hocini, Meleze
    Sacher, Frederic
    Klein, George J.
    Clementy, Jacques
    Haissaguerre, Michel
    [J]. CIRCULATION, 2007, 116 (13) : 1515 - 1523
  • [10] Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins -: Lessons from double lasso technique
    Ouyang, FF
    Antz, M
    Ernst, S
    Hachiya, H
    Mavrakis, H
    Deger, FT
    Schaumann, A
    Chun, J
    Falk, P
    Hennig, D
    Liu, XP
    Bänsch, D
    Kuck, KH
    [J]. CIRCULATION, 2005, 111 (02) : 127 - 135