Efficacy of an Extracorporeal Endotoxin Adsorber System during Hyperdynamic Porcine Endotoxemia

被引:7
作者
Bracht, H. [1 ]
Hauser, B. [1 ]
Ivanyi, Z. [1 ]
Asfar, P. [1 ]
Ehrmann, U. [1 ]
Brueckner, U. B. [2 ]
GeorgieffA, M. [1 ]
Radermacher, P. [1 ]
Buttenschoen, K. [3 ]
机构
[1] Univ Ulm Klinikum, Sekt Anesthesiol Pathophysiol & Verfahrensentwick, DE-89073 Ulm, Germany
[2] Univ Ulm Klinikum, Sekt Chirurg Forsch, DE-89073 Ulm, Germany
[3] Univ Ulm Klinikum, Abt Allgemein Visceral & Transplantat Chirurg, DE-89073 Ulm, Germany
关键词
Endotoxin adsorber; Immobilized human serum albumin; Animal trial; Pig; Endotoxic shock; B-IMMOBILIZED FIBER; GRAM-NEGATIVE SEPSIS; SEPTIC SHOCK; CONTROLLED-TRIAL; SHORT-TERM; HEMOPERFUSION; COLUMN; HEMOFILTRATION; BACTEREMIA; ADSORPTION;
D O I
10.1159/000218330
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Endotoxemia is a crucial factor in the pathogenesis of sepsis. Elimination of endotoxin is aimed at the reduction of sepsis-related morbidity and lethality. The objective of this study was to examine the impact of an endotoxin adsorber on hemodynamics, O(2) exchange and metabolism during resuscitated porcine endotoxemia. Methods: Twenty pigs were randomized into 2 intervention groups (n = 7 each) and 1 control group (n = 6). Endotoxemia was induced by continuous intravenous application of lipopolysaccharide for 8 h. Adsorber therapy was started at the same time as the induction of endotoxemia or 2 h later. An extracorporeal hemoperfusion device using immobilized human serum albumin for endotoxin adsorption was used. Results: Hemodynamic, metabolic and acid-base parameters, as well as the kinetics of interleukin (IL)-6, IL-8, IL-10 and tumor necrosis factor-alpha, were characteristic for endotoxic shock. Endotoxin plasma levels were low (arterial, hepatic and portal vein). None of the parameters were significantly influenced by the adsorber system. Conclusion: Despite typical clinical signs of endotoxemia, the adsorber system had no significant effect on hemodynamic, metabolic and acid-base parameters during endotoxic shock. The reasons for the absence of an effect are elusive; however, failure of the method per se or exceeded capacity of the adsorber cannot be excluded. Copyright (C) 2009 S. Karger AG, Basel
引用
收藏
页码:53 / 60
页数:8
相关论文
共 31 条
[31]   CONTINUOUS HEMATOCRIT MONITORING METHOD IN AN EXTRACORPOREAL-CIRCULATION SYSTEM AND ITS APPLICATION FOR AUTOMATIC-CONTROL OF BLOOD-VOLUME DURING ARTIFICIAL-KIDNEY TREATMENT [J].
ISHIHARA, T ;
IGARASHI, I ;
KITANO, T ;
SHINZATO, T ;
MAEDA, K .
ARTIFICIAL ORGANS, 1993, 17 (08) :708-716