Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry A comparative evaluation on image quality and radiation exposure

被引:0
|
作者
Hofmann, Elisabeth [1 ]
Schmid, Matthias [2 ]
Lell, Michael [3 ,4 ]
Hirschfelder, Ursula [1 ]
机构
[1] Univ Klinikum Erlangen, Dept Orthodont & Orofacial Orthoped, Zahnklin Kieferorthopadie 3, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
[3] Univ Klinikum Erlangen, Dept Radiol, D-91054 Erlangen, Germany
[4] Imaging Sci Inst ISI, Erlangen, Germany
来源
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE | 2014年 / 75卷 / 05期
关键词
Diagnostic imaging; Radiation dose; Organ dose; Image quality; Dental radiography; CBCT DEVICES; CT; DOSIMETRY; SCANNERS; MSCT; REDUCTION; RADIOLOGY; AGREEMENT; ACCURACY;
D O I
10.1007/s00056-014-0232-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The goal of the present work was to assess various computed tomography (CT) systems in term of image quality and organ doses, namely five cone-beam CT (CBCT) scanners operated at standard settings and three multislice CT (MSCT) scanners operated at greatly dose-reduced settings. Radiographic volume scans were taken on a complete human cadaveric head specimen and the image quality of each was rated by four experienced examiners according to specific skeletal structures and bone-soft tissue interfaces. Radiation doses were captured by a head-and-neck phantom (Rando; Alderson Research Laboratories). Standard protocols were used for the CBCT scans. For the MSCT scans, tube voltage and current were adjusted to minimize radiation without compromising image quality. Interobserver agreement was close to perfect, with iota coefficients of 0.931 (95 % CI 0.807-0.978) between groups 1 and 2 and 0.959 (95 % CI 0.869-1.000) between groups 1 and 3. Ratings of image quality in terms of skeletal-structure representation were slightly better for the CBCT than the MSCT scanners, although these differences were not statistically significant. The two groups of scanners applied considerably different organ doses: the lowest dose (0.03 mSv) was measured on the bone surface with a CBCT unit (Picasso TrioA (R) from Vatech) and the highest dose (8.30 mSv) in the vicinity of the eye lens with another CBCT unit (3D Accuitomo 170A (R) from J. Morita). The various systems tested offer similar imaging quality but demonstrated distinct differences in organ dose levels. The decision on which approach to take is not between CBCT and MSCT but rather between specific models and parameter settings. If these are optimized, MSCT images providing useful clinical information can be obtained at much reduced levels of radiation. Depending on the model and setting used, MSCT radiation levels may even be lower than during CBCT scans.
引用
收藏
页码:384 / 398
页数:15
相关论文
共 50 条
  • [21] EVALUATION OF THYROID RADIATION DOSE USING CONE BEAM COMPUTED TOMOGRAPHY
    Penteado Setti da Rocha, Anna Silvia
    Aguiar, Guilherme de Mello
    Tulio, Ana Paula
    Ditzel, Alessandra S.
    Filipov, Danielle
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 368 - 372
  • [22] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Sailer, Anna M.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    de Graaf, Rick
    van Zwam, Willem H.
    de Haan, Michiel W.
    Kemerink, Gerrit J.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 112 - 120
  • [23] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231
  • [24] Cone Beam Computed Tomography in Veterinary Dentistry
    Van Thielen, Bert
    Siguenza, Francis
    Hassan, Bassam
    JOURNAL OF VETERINARY DENTISTRY, 2012, 29 (01) : 27 - 34
  • [25] Cone beam computed tomography use in orthodontics
    Nervina, J. M.
    AUSTRALIAN DENTAL JOURNAL, 2012, 57 : 95 - 102
  • [26] Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program
    Hohl, C.
    Muehlenbruch, G.
    Wildberger, J. E.
    Leidecker, C.
    Suss, C.
    Schmidt, T.
    Guenther, R. W.
    Mahnken, A. H.
    EUROPEAN RADIOLOGY, 2006, 16 (08) : 1841 - 1846
  • [27] Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program
    C. Hohl
    G. Mühlenbruch
    J. E. Wildberger
    C. Leidecker
    C. Süß
    T. Schmidt
    R. W. Günther
    A. H. Mahnken
    European Radiology, 2006, 16 : 1841 - 1846
  • [28] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [29] Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography
    Hirschinger, Veronika
    Hanke, Sebastian
    Hirschfelder, Ursula
    Hofmann, Elisabeth
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2015, 76 (02): : 152 - 163
  • [30] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378