Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density

被引:18
|
作者
Ab-Lazid, Rosidah [1 ]
Perilli, Egon [1 ]
Ryan, Melissa K. [1 ]
Costi, John J. [1 ]
Reynolds, Karen J. [1 ]
机构
[1] Flinders Univ S Australia, Med Device Res Inst, Sch Comp Sci Engn & Math, Biomech & Implants Res Grp, Adelaide, SA 5001, Australia
基金
英国医学研究理事会;
关键词
Screw pullout strength; Trabecular bone; Microarchitecture; Areal bone mineral density; Micro-computed tomography; MECHANICAL-PROPERTIES; OSTEOPOROTIC BONE; HOLDING POWER; FIXATION; FAILURE; STABILITY; CALCANEUS;
D O I
10.1016/j.jmbbm.2014.09.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For cancellous bone screws, the respective roles of the applied insertion torque (T-Insert) and of the quality of the host bone (microarchitecture, areal bone mineral density (aBMD)), in contributing to the mechanical holding strength of the bone-screw construct (F-Pullout), are still unclear. During orthopaedic surgery screws are tightened, typically manually, until adequate compression is attained, depending on surgeons' manual feel. This corresponds to a subjective insertion torque control, and can lead to variable levels of tightening, including screw stripping. The aim of this study, performed on cancellous screws inserted in human femoral heads, was to investigate which, among the measurements of aBMD, bone microarchitecture, and the applied T-Insert has the strongest correlation with F-Pullout. Forty six femoral heads were obtained, over which microarchitecture and aBMD were evaluated using micro-computed tomography and dual X-ray absorptiometry. Using an automated micro-mechanical test device, a cancellous screw was inserted in the femoral heads at T-Insert set to 55% to 99% of the predicted stripping torque beyond screw head contact, after which F-Pullout was measured. F-Pullout exhibited strongest correlations with T-Insert (R=0.88, p <0.001), followed by structure model index (SMI, R= -0.81, p <0.001), bone volume fraction (BV/TV, R=0.73, p <0.001) and aBMD (R=0.66, p <0.01). Combinations of T-Insert with microarchitectural parameters and/or aBMD did not improve the prediction of F-Pullout. These results indicate that, for cancellous screws, F-Pullout depends most strongly on the applied T-Insert, followed by microarchitecture and aBMD of the host bone. In trabecular bone, screw tightening increases the holding strength of the screw-bone construct. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 6 条
  • [1] Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?
    Ab-Lazid, Rosidah
    Perilli, Egon
    Ryan, Melissa K.
    Costi, John J.
    Reynolds, Karen J.
    JOURNAL OF BIOMECHANICS, 2014, 47 (02) : 347 - 353
  • [2] Effect of pilot hole diameter and tapping on insertion torque and axial pullout strength of 4.0-mm cancellous bone screws
    Kunkel, Kevin A. R.
    Suber, Jonathan T.
    Gerard, Patrick D.
    Kowaleski, Michael P.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (12) : 1660 - 1665
  • [3] Relationship of femoral neck areal bone mineral density to volumetric bone mineral density, bone size, and femoral strength in men and women
    Srinivasan, B.
    Kopperdahl, D. L.
    Amin, S.
    Atkinson, E. J.
    Camp, J.
    Robb, R. A.
    Riggs, B. L.
    Orwoll, E. S.
    Melton, L. J., III
    Keaveny, T. M.
    Khosla, S.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 (01) : 155 - 162
  • [4] Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine
    Reitman, CA
    Nguyen, L
    Fogel, GR
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (04): : 306 - 311
  • [5] A new approach for measuring the trabecular bone density through the echosound backscattering: An ex vivo validation on human femoral heads
    De Marco, Tommaso
    Peccarisi, Marco
    Conversano, Francesco
    Greco, Antonio
    Chiozzi, Samanta
    De Pascalis, Fabio
    Casciaro, Sergio
    MEASUREMENT, 2016, 87 : 51 - 61
  • [6] An in vitro biomechanical comparison of the insertion variables and pullout mechanical properties of AO 6.5-mm standard cancellous and 7.3-mm self-tapping, cannulated bone screws in foal femoral bone
    Johnson, NL
    Galuppo, LD
    Stover, SM
    Taylor, KT
    VETERINARY SURGERY, 2004, 33 (06) : 681 - 690